Literature DB >> 12113299

Development of immunoturbidimetric assays for fourteen human serum proteins on the Hitachi 912.

Thomas B Ledue1, Marilyn F Collins, Robert F Ritchie.   

Abstract

Many laboratories rely on dedicated nephelometers or turbidimeters and commercial reagent kits for the evaluation of serum proteins. However, with growing emphasis on cost containment, laboratories are forced to seek additional operational efficiencies by capitalizing on the use of existing analyzers whenever possible. In the present paper we describe the development of immunoturbidimetric assays for routine analysis of 14 human serum proteins (alpha1-antitrypsin, alpha2-macroglobulin, albumin, apolipoproteins Al and B, complement components 3 and 4, haptoglobin, immunoglobulins A, G, and M, orosomucoid, prealbumin, and transferrin) on the Hitachi 912, a general chemistry analyzer. With this system, we obtained excellent precision at levels corresponding to low, normal, and high physiologic concentrations of each protein (within-run imprecision CVs < or = 3.4%, total imprecision CVs < or = 4.1%). Linearity for each method was within 5% of the expected value throughout the calibration range, and method comparisons with either the Roche turbidimetric or Dade Behring nephelometric assays were in good agreement (r >0.97). We observed no significant interference from bilirubin (up to 718 micromol/l), hemoglobin (up to 8 g/l), triglyceride (up to 14.7 mmol/l) or rheumatoid factor (up to 4,140 IU/ml). Calibration for the 14 protein assays was stable for at least 7 days and onboard refrigerated reagents were stable for at least 3 months. The instrument's automated sample re-run feature minimized sample handling and helped to conserve specimens. In conclusion, the newly developed assays on the Hitachi 912 offer high throughput (>250 tests per hour) without the associated cost of a dedicated instrument for protein assays.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12113299     DOI: 10.1515/CCLM.2002.090

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  5 in total

Review 1.  Validation and quality control of protein microarray-based analytical methods.

Authors:  Larry J Kricka; Stephen R Master
Journal:  Mol Biotechnol       Date:  2007-08-03       Impact factor: 2.695

2.  Testosterone's short-term positive effect on luteinizing-hormone secretory-burst mass and its negative effect on secretory-burst frequency are attenuated in middle-aged men.

Authors:  Peter Y Liu; Paul Y Takahashi; Pamela D Roebuck; Joy N Bailey; Daniel M Keenan; Johannes D Veldhuis
Journal:  J Clin Endocrinol Metab       Date:  2009-07-07       Impact factor: 5.958

3.  Analysis of the impact of intravenous LH pulses versus continuous LH infusion on testosterone secretion during GnRH-receptor blockade.

Authors:  Johannes D Veldhuis; Peter Y Liu; Paul Y Takahashi; Suanne M Weist; Jean R Wigham
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2012-09-19       Impact factor: 3.619

4.  Intake of partially defatted Brazil nut flour reduces serum cholesterol in hypercholesterolemic patients--a randomized controlled trial.

Authors:  Roberta F Carvalho; Grazielle V B Huguenin; Ronir R Luiz; Annie S B Moreira; Glaucia M M Oliveira; Glorimar Rosa
Journal:  Nutr J       Date:  2015-06-16       Impact factor: 3.271

5.  An immunoturbidimetric assay for bovine haptoglobin.

Authors:  Nicola Brady; Emily L O'Reilly; Christopher McComb; Alastair I Macrae; P David Eckersall
Journal:  Comp Clin Path       Date:  2018-11-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.