Literature DB >> 12106735

Evaluation of 3 modern single-piece foldable intraocular lenses: clinicopathological study of posterior capsule opacification in a rabbit model.

Luis G Vargas1, Qun Peng, David J Apple, Marcela Escobar-Gomez, Suresh K Pandey, Stella N Arthur, Daphne S M Hoddinott, Josef M Schmidbauer.   

Abstract

PURPOSE: To assess the development of posterior capsule opacification (PCO) with 3 modern single-piece foldable intraocular lenses (IOLs) in a histopathological study and to compare the potential preventive effects of the IOL design and biomaterial in retarding PCO.
SETTING: Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA.
METHODS: Thirty-one rabbit eyes were randomly operated on with phacoemulsification and implantation of 3 single-piece foldable lenses: a hydrophilic acrylic design, the Rayner Centerflex 570H (n = 11); a hydrophobic acrylic design, the Alcon AcrySof SA30AL (n = 10); and a silicone large-hole plate design, the Staar AA-4203VF (n = 10). Central PCO (CPCO), peripheral PCO (PPCO), and Soemmering's ring formation were evaluated 3 weeks after surgery using the Miyake-Apple posterior photographic technique. Histological sections of each globe were prepared to document capsular bag status and performance of IOL geometry.
RESULTS: The acrylic IOLs (Centerflex and AcrySof) had lower CPCO and PPCO scores than the silicone plate IOL (P <.05). There was no significant difference in Soemmering's ring formation among the 3 models. Pathological evaluations revealed effective blockage of migrating lens epithelial cells (LECs) at the site of the truncated optic edge of the Centerflex and AcrySof IOLs, even in the presence of large amounts of retained/regenerative cortical material.
CONCLUSIONS: The AcrySof IOL has a hydrophobic surface and the Centerflex a hydrophilic surface, but no correlation to these characteristics could be identified. The single-piece AcrySof optic geometry created a clear-cut barrier effect equal to that of its 3-piece predecessor. The anatomic profile of the Centerflex IOL shows the same characteristics. The optics of both acrylic lenses have square truncated edges that functionally block ingrowth of migrating LECs toward the central visual axis, leaving clear posterior capsules. The square optic edge was an appropriate geometric configuration to create a barrier effect. There was no effect of the biomaterial on PCO prevention.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12106735     DOI: 10.1016/s0886-3350(02)01216-6

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  9 in total

1.  Single versus three piece acrylic IOLs.

Authors:  D F Chang
Journal:  Br J Ophthalmol       Date:  2004-06       Impact factor: 4.638

2.  [Influence of intraocular lens material and design on the development of posterior capsule opacification].

Authors:  O Nishi
Journal:  Ophthalmologe       Date:  2005-06       Impact factor: 1.059

3.  Prospective, non-randomised, long term clinical evaluation of a foldable hydrophilic single piece intraocular lens: results of the Centerflex FDA study.

Authors:  K A Becker; M Martin; T M Rabsilber; B B Entz; A J Reuland; G U Auffarth
Journal:  Br J Ophthalmol       Date:  2006-05-10       Impact factor: 4.638

4.  Evaluation of a human capsular bag model for secondary cataract determination after intraocular lens implantation.

Authors:  A Liekfeld; N Pahms; N Torun; A U Porstmann; J Jaroszewski; C Hartmann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-09-10       Impact factor: 3.117

5.  [Quantitative evaluation of acrylic and silicone intraocular lenses with a sharp optic edge design].

Authors:  T M Rabsilber; A J Reuland; B B Entz; M P Holzer; I J Limberger; G U Auffarth
Journal:  Ophthalmologe       Date:  2006-01       Impact factor: 1.059

6.  Light-adjustable lens.

Authors:  Daniel M Schwartz
Journal:  Trans Am Ophthalmol Soc       Date:  2003

7.  Findings of an experimental study in a rabbit model on posterior capsule opacification after implantation of hydrophobic acrylic and hydrophilic acrylic intraocular lenses.

Authors:  Nikolaos Trakos; Elli Ioachim; Elena Tsanou; Miltiadis Aspiotis; Konstantinos Psilas; Chris Kalogeropoulos
Journal:  Clin Ophthalmol       Date:  2008-12

8.  A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses.

Authors:  R Nejima; K Miyata; M Honbou; T Tokunaga; T Tanabe; M Sato; T Oshika
Journal:  Br J Ophthalmol       Date:  2004-06       Impact factor: 4.638

9.  Two-dimensional ultrathin Ti3C2 MXene nanosheets coated intraocular lens for synergistic photothermal and NIR-controllable rapamycin releasing therapy against posterior capsule opacification.

Authors:  Zi Ye; Yang Huang; Jinglan Li; Tianju Ma; Lixiong Gao; Huihui Hu; Qing He; Haiying Jin; Zhaohui Li
Journal:  Front Bioeng Biotechnol       Date:  2022-08-30
  9 in total