Literature DB >> 12101473

New technical developments in multislice CT--Part 1: Approaching isotropic resolution with sub-millimeter 16-slice scanning.

T Flohr1, K Stierstorfer, H Bruder, J Simon, S Schaller.   

Abstract

The introduction of multislice CT was a breakthrough with regard to increased scan speed, improved axial resolution and better utilization of the tube output. The new generation of multislice CT scanners offering simultaneous acquisition of up to 16 sub-millimeter slices represents an important leap on the way towards true isotropic scanning. We present an evaluation of a state-of-the-art 16-slice CT system (SOMATOM Sensation 16, Siemens AG, Forchheim, Germany). After an introduction to the detector design we discuss dose utilization and finally elaborate on multislice spiral scanning with 16 slices. Due to the increased number of slices dose utilization is improved compared to current 4-slice CT scanners, and sub-millimeter collimation needs no longer be restricted to special applications. For CT systems with 8 or more slices, the cone-beam geometry causes severe artifacts if not corrected for by a so-called cone-correction, which thus becomes mandatory in this case. With the Adaptive Multiple Plane Reconstruction AMPR, cone beam artifacts are effectively suppressed, while the benefits of Adaptive Axial Interpolation are maintained: free selection of the spiral pitch according to the clinical needs of an examination, slice width independent of the pitch, full dose utilization at all pitch values. Clinical practice will have to demonstrate the application spectrum that is opened with the new generation of multislice CT systems.

Mesh:

Year:  2002        PMID: 12101473     DOI: 10.1055/s-2002-32692

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  20 in total

1.  Non-invasive 16-row multislice CT coronary angiography: usefulness of saline chaser.

Authors:  Filippo Cademartiri; Nico Mollet; Aad van der Lugt; Koen Nieman; Peter M T Pattynama; Pim J de Feyter; Gabriel P Krestin
Journal:  Eur Radiol       Date:  2003-12-19       Impact factor: 5.315

Review 2.  Pneumonia in neutropenic patients.

Authors:  C P Heussel; H-U Kauczor; A J Ullmann
Journal:  Eur Radiol       Date:  2003-07-24       Impact factor: 5.315

3.  [Current status and future potentials of multislice computed tomography].

Authors:  T Flohr; B Ohnesorge; S Schaller
Journal:  Radiologe       Date:  2004-02       Impact factor: 0.635

4.  Flat-panel versus 64-channel computed tomography for in vivo quantitative characterization of aortic atherosclerotic plaques.

Authors:  Ibrahim Aboshady; Dianna D Cody; Evan M Johnson; Amir Gahremanpour; Deborah Vela; Kamal G Khalil; Herbert L Dupont; James T Willerson; L Maximilian Buja; Gregory W Gladish
Journal:  Int J Cardiol       Date:  2010-12-24       Impact factor: 4.164

5.  [Multidetector computed tomography of the liver].

Authors:  W Schima; C Kulinna; A Ba-Ssalamah; T Grünberger
Journal:  Radiologe       Date:  2005-01       Impact factor: 0.635

6.  Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience.

Authors:  Konstantin Nikolaou; Thomas Flohr; Karl Stierstorfer; Christoph R Becker; Maximilian F Reiser
Journal:  Eur Radiol       Date:  2004-11-20       Impact factor: 5.315

7.  Advances in cardiac CT imaging: 64-slice scanner.

Authors:  Konstantin Nikolaou; Thomas Flohr; Andreas Knez; Carsten Rist; Bernd Wintersperger; Thorsten Johnson; Maximilian F Reiser; Christoph R Becker
Journal:  Int J Cardiovasc Imaging       Date:  2004-12       Impact factor: 2.357

Review 8.  Diagnosing pulmonary embolism: time to rewrite the textbooks.

Authors:  U Joseph Schoepf
Journal:  Int J Cardiovasc Imaging       Date:  2005-02       Impact factor: 2.357

9.  Impact of the introduction of 16-row MDCT on image quality and patient dose: Phantom study and multi-centre survey.

Authors:  Francis R Verdun; Nicolas Theumann; Pierre-Alexandre Poletti; Daniel Gutierrez; Abbas Aroua; Pierre Schnyder; Jean-François Valley; Salah D Qanadli
Journal:  Eur Radiol       Date:  2006-08-29       Impact factor: 5.315

10.  Multidetector CT (64 Slices) of the liver: examination techniques.

Authors:  Andrea Laghi
Journal:  Eur Radiol       Date:  2006-09-29       Impact factor: 5.315

View more