Literature DB >> 12091690

Detection of simulated chest lesions by using soft-copy reading: comparison of an amorphous silicon flat-panel-detector system and a storage-phosphor system.

Jin Mo Goo1, Jung-Gi Im, Hyun Ju Lee, Myung Jin Chung, Joon Beom Seo, Hyae Young Kim, Yu-Jin Lee, Joon-Won Kang, Jong Hyo Kim.   

Abstract

PURPOSE: To compare observer performance by using soft-copy images produced by an amorphous silicon flat-panel-detector system and a storage-phosphor system for the detection of simulated chest lesions.
MATERIALS AND METHODS: To test the diagnostic performance of these two systems, four types of simulated lesions (nodules, micronodules, lines, and reticular opacities) were superimposed over an anthropomorphic chest phantom. Digital chest radiographs were acquired with amorphous silicon flat-panel-detector (3-K [K = 1,000] matrix, 12 bits) and storage-phosphor radiography (4-K matrix, 10 bits). Six board-certified radiologists evaluated soft-copy images on a high-resolution video monitor (2,048 x 2,560 x 8 bits). A total of 14,400 observations were analyzed in terms of receiver operating characteristics.
RESULTS: Average performance in terms of nodule detection was significantly better (P <.05) with the flat-panel-detector system than with the storage-phosphor system. For micronodules, lines, and reticular opacities, no significant detection differences in averaged performance were found between the two detector systems.
CONCLUSION: In the evaluation of soft-copy images, the amorphous silicon detector system appears to be superior to the storage-phosphor system for the detection of pulmonary nodules.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12091690     DOI: 10.1148/radiol.2241011441

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Contrast-detail evaluation and dose assessment of eight digital chest radiography systems in clinical practice.

Authors:  Wouter J H Veldkamp; Lucia J M Kroft; Mireille V Boot; Bart J A Mertens; Jacob Geleijns
Journal:  Eur Radiol       Date:  2005-08-31       Impact factor: 5.315

2.  Pulmonary nodule detection with digital projection radiography: an ex-vivo study on increased latitude post-processing.

Authors:  Juergen Biederer; Tobias Gottwald; Hendrik Bolte; Christian Riedel; Sandra Freitag; Richard Van Metter; Martin Heller
Journal:  Eur Radiol       Date:  2006-09-09       Impact factor: 5.315

3.  An investigation into the validity of utilising the CDRAD 2.0 phantom for optimisation studies in digital radiography.

Authors:  Sadeq Al-Murshedi; Peter Hogg; Andrew England
Journal:  Br J Radiol       Date:  2018-07-05       Impact factor: 3.039

4.  Basic imaging properties of an indirect flat-panel detector system employing irradiation side sampling (ISS) technology for chest radiography: comparison with a computed radiographic system.

Authors:  Nobukazu Tanaka; Yuki Yano; Hidetake Yabuuchi; Tsutomu Akasaka; Masayuki Sasaki; Masafumi Ohki; Junji Morishita
Journal:  Radiol Phys Technol       Date:  2012-11-10

5.  Detectability of simulated interstitial pneumonia on chest radiographs: comparison between irradiation side sampling indirect flat-panel detector and computed radiography.

Authors:  Y Yano; H Yabuuchi; A Kairada; N Tanaka; J Morishita; T Akasaka; Y Matsuo; T Kamitani; Y Yamasaki; M Nagao; M Sasaki
Journal:  Br J Radiol       Date:  2014-05-29       Impact factor: 3.039

6.  Evaluation of image quality and task performance for a mobile C-arm with a complementary metal-oxide semiconductor detector.

Authors:  Godwin O Abiola; Niral M Sheth; Wojciech Zbijewski; Matthew W Jacobson; Christopher Bailey; John Filtes; Gerhard Kleinszig; Sebastian K Vogt; Stefan Soellradl; Jens Bialkowski; William S Anderson; Jeffrey H Siewerdsen; Clifford R Weiss
Journal:  J Med Imaging (Bellingham)       Date:  2020-01-24
  6 in total