Literature DB >> 12089500

Ankle joint range of motion measurements in spastic cerebral palsy children: intraobserver and interobserver reliability and reproducibility of goniometry and visual estimation.

Nanni J Allington1, Nathalie Leroy, Carole Doneux.   

Abstract

The aim of this study was to assess the intra- and interobserver reliability and reproducibility of goniometry and visual estimation of ankle joint range of motion measurements in children with spastic cerebral palsy. Forty-six ankles of 24 spastic cerebral palsy children were measured under a strict protocol. The global mean measurement error was 5 degrees (SD, 5 degrees) for intra- and interobserver measurements and 3 degrees (SD, 3 degrees) for goniometry versus visual estimation. Statistical analysis showed a high reliability for intra- and interobserver measurements (r>0.75), between visual estimation and goniometry (correlation coefficient, r>0.967; concordance coefficient, r>0.957). Both visual estimation and goniometry ankle range-of-motion measurements are reliable and reproducible in spastic cerebral palsy children if a strict but simple protocol is applied.

Entities:  

Mesh:

Year:  2002        PMID: 12089500     DOI: 10.1097/00009957-200207000-00007

Source DB:  PubMed          Journal:  J Pediatr Orthop B        ISSN: 1060-152X            Impact factor:   1.041


  12 in total

1.  Stability of serial range-of-motion measurements of the lower extremities in children with cerebral palsy: can we do better?

Authors:  Johanna Darrah; Lesley Wiart; Jan Willem Gorter; Mary Law
Journal:  Phys Ther       Date:  2014-02-20

2.  Quantifying Effect of Onabotulinum Toxin A on Passive Muscle Stiffness in Children with Cerebral Palsy Using Ultrasound Shear Wave Elastography.

Authors:  Joline E Brandenburg; Sarah F Eby; Pengfei Song; William R Bamlet; Gary C Sieck; Kai-Nan An
Journal:  Am J Phys Med Rehabil       Date:  2018-07       Impact factor: 2.159

3.  Reliability of goniometric measurements in children with cerebral palsy: a comparative analysis of universal goniometer and electronic inclinometer. A pilot study.

Authors:  Pablo Herrero; Patricia Carrera; Elena García; Eva M Gómez-Trullén; Bárbara Oliván-Blázquez
Journal:  BMC Musculoskelet Disord       Date:  2011-07-10       Impact factor: 2.362

4.  Feasibility and reliability of quantifying passive muscle stiffness in young children by using shear wave ultrasound elastography.

Authors:  Joline E Brandenburg; Sarah F Eby; Pengfei Song; Heng Zhao; Bradford W Landry; Shirley Kingsley-Berg; William R Bamlet; Shigao Chen; Gary C Sieck; Kai-Nan An
Journal:  J Ultrasound Med       Date:  2015-04       Impact factor: 2.153

5.  Assessment of muscle shortening and static posture in children with persistent asthma.

Authors:  Erica A Lopes; Adriana Fanelli-Galvani; Camilla C V Prisco; Raquel C Gonçalves; Cristina M A Jacob; Anna L B Cabral; Milton A Martins; Celso R F Carvalho
Journal:  Eur J Pediatr       Date:  2006-11-16       Impact factor: 3.183

6.  Ipsilateral hip abductor weakness after inversion ankle sprain.

Authors:  Karen Friel; Nancy McLean; Christine Myers; Maria Caceres
Journal:  J Athl Train       Date:  2006 Jan-Mar       Impact factor: 2.860

7.  Quantifying passive muscle stiffness in children with and without cerebral palsy using ultrasound shear wave elastography.

Authors:  Joline E Brandenburg; Sarah F Eby; Pengfei Song; Shirley Kingsley-Berg; William Bamlet; Gary C Sieck; Kai-Nan An
Journal:  Dev Med Child Neurol       Date:  2016-07-04       Impact factor: 5.449

8.  Is visual estimation of passive range of motion in the pediatric lower limb valid and reliable?

Authors:  Rami Rachkidi; Ismat Ghanem; Ibrahim Kalouche; Samer El Hage; Fernand Dagher; Khalil Kharrat
Journal:  BMC Musculoskelet Disord       Date:  2009-10-12       Impact factor: 2.362

9.  Agreement between visual and goniometric assessments of adductor and popliteal angles in infants.

Authors:  Thejus T Jayakrishnan; Suvasini Sharma; Sheffali Gulati; R M Pandey; Sanjay Wadhwa; Vinod K Paul
Journal:  J Pediatr Neurosci       Date:  2013-05

10.  Intra-observer and inter-observer reliability of leg circumference measurement among six observers: a single blinded randomized trial.

Authors:  Y Bakar; Ö C Özdemir; S Sevim; E Duygu; A Tuğral; M Sürmeli
Journal:  J Med Life       Date:  2017 Jul-Sep
View more