Comparison of pulmonary arterial thermodilution and arterial pulse contour analysis: evaluation of a new algorithm.

Thomas W Felbinger1, Daniel A Reuter, Holger K Eltzschig, Karl Moerstedt, Oliver Goedje, Alwin E Goetz.   

Abstract

STUDY
OBJECTIVE: To compare cardiac index (CI) measurement by arterial pulse contour analysis using two different algorithms (CI(PC), CI(PCnew)) with pulmonary arterial thermodilution values (CI(PA)) so as to evaluate the difference between the conventional algorithm, CI(PC), and a new algorithm, CI(PCnew), that accounts for patients' individual aortic compliance.
DESIGN: Prospective, clinical study.
SETTING: Intensive care unit of a university hospital. PATIENTS: 20 ASA physical status II and III patients following elective cardiac surgery.
MEASUREMENTS AND MAIN RESULTS: 360 parallel triplicate determinations of CI (CI(PA), CI(PC), CI(PCnew)) were performed within a 90-minute period during the immediate postoperative period. Prior to the start of the study period, CI(PC) as well as CI(PCnew) were calibrated by triplicate femoral arterial thermodilution measurements. Regression analysis of CI(PA) and CI(PC), as well as CI(PA) and CI(PCnew), revealed r = 0.89, p < 0.001, and r = 0.93, p < 0.001, respectively. Bland-Altman analysis was used for determining the accuracy and precision of CI(PC) and CI(PCnew) compared with CI(PA). The mean differences (m) and standard deviation (SD) between CI(PA) and CI(PC,) as well as CI(PA) and CI(PCnew), resulted in m = -0.312 L/min/m(2), SD = 0.456 L/min/m(2), and m = - 0.140 L/min/m(2), SD = 0.328 L/min/m(2), respectively.
CONCLUSION: Arterial pulse contour analysis measurement of CI using either algorithm correlates well with CI values derived by pulmonary arterial thermodilution. However, the algorithm introduced in this study proved to be a more accurate predictor of values as derived by pulmonary artery catheter.

Entities:  

Mesh:

Year:  2002        PMID: 12088815     DOI: 10.1016/s0952-8180(02)00363-x

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  13 in total

Review 1.  [Measurement of cardiac output].

Authors:  D A Reuter; A E Goetz
Journal:  Anaesthesist       Date:  2005-11       Impact factor: 1.041

2.  A new non-invasive continuous cardiac output trend solely utilizing routine cardiovascular monitors.

Authors:  Hironori Ishihara; Hirobumi Okawa; Ken Tanabe; Toshihito Tsubo; Yoshihiro Sugo; Takeshi Akiyama; Sunao Takeda
Journal:  J Clin Monit Comput       Date:  2004-12       Impact factor: 2.502

Review 3.  Methods in pharmacology: measurement of cardiac output.

Authors:  Bart F Geerts; Leon P Aarts; Jos R Jansen
Journal:  Br J Clin Pharmacol       Date:  2011-03       Impact factor: 4.335

4.  [Accuracy of pulse contour cardiac index measurements during changes of preload and aortic impedance].

Authors:  T W Felbinger; M S Goepfert; T Goresch; A E Goetz; D A Reuter
Journal:  Anaesthesist       Date:  2005-08       Impact factor: 1.041

5.  Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients.

Authors:  Daniel A Reuter; Julian Bayerlein; Matthias S G Goepfert; Florian C Weis; Erich Kilger; Peter Lamm; Alwin E Goetz
Journal:  Intensive Care Med       Date:  2003-02-11       Impact factor: 17.440

6.  S3 guidelines for intensive care in cardiac surgery patients: hemodynamic monitoring and cardiocirculary system.

Authors:  M Carl; A Alms; J Braun; A Dongas; J Erb; A Goetz; M Goepfert; W Gogarten; J Grosse; A R Heller; M Heringlake; M Kastrup; A Kroener; S A Loer; G Marggraf; A Markewitz; D Reuter; D V Schmitt; U Schirmer; C Wiesenack; B Zwissler; C Spies
Journal:  Ger Med Sci       Date:  2010-06-15

7.  Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices.

Authors:  Xavier Monnet; Nadia Anguel; Brice Naudin; Julien Jabot; Christian Richard; Jean-Louis Teboul
Journal:  Crit Care       Date:  2010-06-10       Impact factor: 9.097

8.  Stroke volume determination using transcardiopulmonary thermodilution and arterial pulse contour analysis in severe aortic valve disease.

Authors:  Martin Petzoldt; Carsten Riedel; Jan Braeunig; Sebastian Haas; Matthias S Goepfert; Hendrik Treede; Stephan Baldus; Alwin E Goetz; Daniel A Reuter
Journal:  Intensive Care Med       Date:  2013-01-04       Impact factor: 17.440

Review 9.  [Assessment of volume responsiveness in mechanically ventilated patients].

Authors:  D A Reuter; A E Goetz; K Peter
Journal:  Anaesthesist       Date:  2003-11       Impact factor: 1.041

10.  Effect of norepinephrine dosage and calibration frequency on accuracy of pulse contour-derived cardiac output.

Authors:  Matthias Gruenewald; Patrick Meybohm; Jochen Renner; Ole Broch; Amke Caliebe; Norbert Weiler; Markus Steinfath; Jens Scholz; Berthold Bein
Journal:  Crit Care       Date:  2011-01-17       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.