Literature DB >> 12074452

Histologic comparison of a thermal dual-etched implant surface to machined, TPS, and HA surfaces: bone contact in vivo in rabbits.

Robert M London1, Frank A Roberts, David A Baker, Michael D Rohrer, Robert B O'Neal.   

Abstract

PURPOSE: To evaluate the bone contact percentage around a proprietary high-temperature dual-etched (DE) implant surface (Osseotite) versus implants with machined, hydroxyapatite (HA), and titanium plasma-sprayed (TPS) surfaces.
MATERIALS AND METHODS: Each implant type was placed in rabbit tibiae of the same animal and assessed at 1 to 8 weeks. Histologic sections were prepared and analyzed histomorphometrically.
RESULTS: The DE implant surface achieved higher levels of bone contact percentage than the other surfaces. This enhanced contact level was apparent by 3 weeks and seen at all time intervals except 2 weeks, at which machined exceeded the DE mean. In evaluating which surface outscored the others in each individual rabbit, there was a statistically significant confidence for the DE surface (P < .001). The other 3 surfaces failed to show significance, although the numeric scores for the TPS surfaces were below random expectations and the machined scores were slightly above. There was no correlation between degree of roughness and bone contact percentage. DISCUSSION: Arbitrarily roughening the implant surface may not result in a large change in bone conductivity. The specific texture of the DE process yielded more contact, possibly as the result of better fibrin clot retention and growth factor enhancement.
CONCLUSIONS: There was no advantage demonstrated in this model to an HA surface over titanium. The bone contact to the rough HA surface scored similarly to that for the TPS surface of similar roughness, and well below that for the DE titanium surface. The DE surface appeared to have an advantage in bone contact percentage, particularly in early healing in a rabbit tibia model.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12074452

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  5 in total

1.  On the Morphological Deviation in Additive Manufacturing of Porous Ti6Al4V Scaffold: A Design Consideration.

Authors:  Seyed Ataollah Naghavi; Haoyu Wang; Swastina Nath Varma; Maryam Tamaddon; Arsalan Marghoub; Rex Galbraith; Jane Galbraith; Mehran Moazen; Jia Hua; Wei Xu; Chaozong Liu
Journal:  Materials (Basel)       Date:  2022-07-06       Impact factor: 3.748

2.  The effect of Er:YAG laser irradiation on hydroxyapatite-coated implants and fluoride-modified TiO2-blasted implant surfaces: a microstructural analysis.

Authors:  Seung-Il Shin; Eun-Kwon Lee; Jeong-Hyun Kim; Ji-Hun Lee; Sun-Hee Kim; Young-Hyuk Kwon; Yeek Herr; Jong-Hyuk Chung
Journal:  Lasers Med Sci       Date:  2012-07-26       Impact factor: 3.161

3.  The effect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of double acid-etched implants.

Authors:  Ji-Hyun Kim; Yeek Herr; Jong-Hyuk Chung; Seung-Il Shin; Young-Hyuk Kwon
Journal:  J Periodontal Implant Sci       Date:  2011-10-31       Impact factor: 2.614

Review 4.  Surface Modifications and Their Effects on Titanium Dental Implants.

Authors:  A Jemat; M J Ghazali; M Razali; Y Otsuka
Journal:  Biomed Res Int       Date:  2015-09-07       Impact factor: 3.411

5.  Decontamination of Dental Implant Surfaces by the Er:YAG Laser Beam: A Comparative in Vitro Study of Various Protocols.

Authors:  Rima Nejem Wakim; Melanie Namour; Hoang Viet Nguyen; Andre Peremans; Toni Zeinoun; Alain Vanheusden; Eric Rompen; Samir Nammour
Journal:  Dent J (Basel)       Date:  2018-12-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.