Literature DB >> 22833287

The effect of Er:YAG laser irradiation on hydroxyapatite-coated implants and fluoride-modified TiO2-blasted implant surfaces: a microstructural analysis.

Seung-Il Shin1, Eun-Kwon Lee, Jeong-Hyun Kim, Ji-Hun Lee, Sun-Hee Kim, Young-Hyuk Kwon, Yeek Herr, Jong-Hyuk Chung.   

Abstract

The purpose of this study was to evaluate the microscopic changes and surface roughness on hydroxyapatite (HA)-coated implants following exposure to different powers and durations of Er:YAG laser irradiation in order to determine the proper pulse energy level and irradiation time. Ten HA-coated implants and ten fluoride-modified TiO2 implants were used. The implants were divided into a control (one implant) and test group (nine implants) for each implant type. Implants in the test groups were sub-divided into three groups (three implants per group) based on the applied laser pulse energy and irradiation time. The measurement of surface roughness was performed on all implants in the test groups using a white light interferometer before and after laser irradiation. R a values were recorded and compared in order to evaluate changes in surface roughness. For HA-coated implants, the R a values increased in all test groups after laser irradiation. However, mean R a values in the fluoride-modified TiO2-blasted implant test group were decreased after irradiation. There was no statistical difference. Scanning electron microscope analysis revealed surface alterations in both the HA-coated and fluoridated TiO2-blasted implants irradiated for 1.5 min at 100 mJ/pulse, 10 Hz. When the pulse energy and irradiation time increased, greater surface alterations, including surface flattening and microfractures, were observed. In conclusion, the results of the current study suggest that no changes could be observed in both HA-coated implants and fluoride-modified TiO2-blasted implants after irradiation at an intensity of 100 mJ/pulse, 10 Hz for 1 min performed to achieve surface detoxification.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22833287     DOI: 10.1007/s10103-012-1162-8

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  39 in total

1.  Effect of an Er:YAG laser on periodontally involved root surfaces: an in vivo and in vitro SEM comparison.

Authors:  F Schwarz; N Pütz; T Georg; E Reich
Journal:  Lasers Surg Med       Date:  2001       Impact factor: 4.025

Review 2.  Experimentally induced peri-implantitis: a review of different treatment methods described in the literature.

Authors:  M Baron; R Haas; O Dörtbudak; G Watzek
Journal:  Int J Oral Maxillofac Implants       Date:  2000 Jul-Aug       Impact factor: 2.804

Review 3.  Lasers in nonsurgical periodontal therapy.

Authors:  Akira Aoki; Katia Miyuki Sasaki; Hisashi Watanabe; Isao Ishikawa
Journal:  Periodontol 2000       Date:  2004       Impact factor: 7.589

4.  Surface characterizations of variously treated titanium materials.

Authors:  Y J Lim; Y Oshida; C J Andres; M T Barco
Journal:  Int J Oral Maxillofac Implants       Date:  2001 May-Jun       Impact factor: 2.804

5.  Conventional versus laser-assisted therapy of periimplantitis: a five-year comparative study.

Authors:  G Bach; C Neckel; C Mall; G Krekeler
Journal:  Implant Dent       Date:  2000       Impact factor: 2.454

6.  Osseointegrated oral implants. A Swedish multicenter study of 8139 consecutively inserted Nobelpharma implants.

Authors:  T Albrektsson; E Dahl; L Enbom; S Engevall; B Engquist; A R Eriksson; G Feldmann; N Freiberg; P O Glantz; O Kjellman
Journal:  J Periodontol       Date:  1988-05       Impact factor: 6.993

7.  The soft tissue response to titanium abutments retrieved from humans and reimplanted in rats. A light microscopic study.

Authors:  L Sennerby; U Lekholm
Journal:  Clin Oral Implants Res       Date:  1993-03       Impact factor: 5.977

8.  Chemical treatment of machined titanium surfaces. An in vitro study.

Authors:  A Krozer; J Hall; I Ericsson
Journal:  Clin Oral Implants Res       Date:  1999-06       Impact factor: 5.977

Review 9.  A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years.

Authors:  Bjarni E Pjetursson; Ken Tan; Niklaus P Lang; Urs Brägger; Matthias Egger; Marcel Zwahlen
Journal:  Clin Oral Implants Res       Date:  2004-12       Impact factor: 5.977

Review 10.  Microbiota around root-form endosseous implants: a review of the literature.

Authors:  Kees Heydenrijk; Henny J A Meijer; Wil A van der Reijden; Gerry M Raghoebar; Arjan Vissink; Boudewijn Stegenga
Journal:  Int J Oral Maxillofac Implants       Date:  2002 Nov-Dec       Impact factor: 2.804

View more
  4 in total

1.  Potential Causes of Titanium Particle and Ion Release in Implant Dentistry: A Systematic Review.

Authors:  Rafael Delgado-Ruiz; Georgios Romanos
Journal:  Int J Mol Sci       Date:  2018-11-13       Impact factor: 5.923

2.  Decontamination of Dental Implant Surfaces by the Er:YAG Laser Beam: A Comparative in Vitro Study of Various Protocols.

Authors:  Rima Nejem Wakim; Melanie Namour; Hoang Viet Nguyen; Andre Peremans; Toni Zeinoun; Alain Vanheusden; Eric Rompen; Samir Nammour
Journal:  Dent J (Basel)       Date:  2018-12-01

3.  Antimicrobial Efficacy of Different Decontamination Methods as Tested on Dental Implants with Various Types of Surfaces.

Authors:  Paweł Kubasiewicz-Ross; Jakub Hadzik; Tomasz Gedrange; Marzena Dominiak; Kamil Jurczyszyn; Artur Pitułaj; Izabela Nawrot-Hadzik; Olga Bortkiewicz; Małgorzata Fleischer
Journal:  Med Sci Monit       Date:  2020-02-20

4.  Efficacy of Er:YAG laser irradiation for decontamination and its effect on biocompatibility of different titanium surfaces.

Authors:  Peijun Huang; Xue Chen; Zhongren Chen; Min Chen; Jinzhi He; Lin Peng
Journal:  BMC Oral Health       Date:  2021-12-18       Impact factor: 2.757

  4 in total