Literature DB >> 12072611

Initial evaluation of the Clarion CII cochlear implant: speech perception and neural response imaging.

Johan H M Frijns1, Jeroen J Briaire, Jan A P M de Laat, Jan J Grote.   

Abstract

OBJECTIVE: To evaluate the new Clarion CII cochlear implant with the perimodiolar HiFocus electrode array, including both speech perception outcomes and the device's capabilities of measuring the electrically evoked compound action potential (eCAP) of the auditory nerve (Neural Response Imaging, NRI).
DESIGN: The speech perception scores on CVC words without lip reading were monitored prospectively for the 10 postlingually deaf patients implanted with the Clarion CII device in the period July 2000 until May 2001 in the Leiden University Medical Center. Preoperative and postoperative NRI recordings were made, applying various combinations of monopolar stimulating and recording electrodes with the alternating polarity paradigm available in the test bench software.
RESULTS: Nine patients preferred the CIS, one the PPS strategy, none the SAS strategy. With their favorite strategy they acquired significant open set speech understanding within a few weeks, resulting in an average CVC phoneme score of 84% (word score 66%) at the end of the study (follow-up 3 to 11 mo). In speech-shaped noise, the average phoneme recognition threshold (PRT) was reached at a signal to noise ratio just below 0 dB. The NRI recordings had clear N1 and P1 peaks if there was at least one contact between the stimulating and recording electrodes, necessitating just 15 sweeps for a reliable recording. We observed considerable inter-patient and inter-electrode variability, but for a given situation NRI input/output curves were stable over time. More apical contacts generally elicited larger eCAPs. Response amplitudes tended to peak at recording sites around apical and basal stimulating electrodes, suggesting a limited spread of excitation. Preliminary recordings with the forward masking paradigm were consistent with the ones with the alternating polarity scheme.
CONCLUSIONS: The Clarion CII is a promising cochlear implant with which our first 10 patients have obtained excellent speech perception results. The NRI system yields high quality signals with a limited number of sweeps at a high sampling rate.

Entities:  

Mesh:

Year:  2002        PMID: 12072611     DOI: 10.1097/00003446-200206000-00003

Source DB:  PubMed          Journal:  Ear Hear        ISSN: 0196-0202            Impact factor:   3.570


  27 in total

1.  Effect of stimulus and recording parameters on spatial spread of excitation and masking patterns obtained with the electrically evoked compound action potential in cochlear implants.

Authors:  Michelle L Hughes; Lisa J Stille
Journal:  Ear Hear       Date:  2010-10       Impact factor: 3.570

2.  Modelling encapsulation tissue around cochlear implant electrodes.

Authors:  T Hanekom
Journal:  Med Biol Eng Comput       Date:  2005-01       Impact factor: 2.602

3.  Multisection CT as a valuable tool in the postoperative assessment of cochlear implant patients.

Authors:  Berit M Verbist; Johan H M Frijns; Jakob Geleijns; Mark A van Buchem
Journal:  AJNR Am J Neuroradiol       Date:  2005-02       Impact factor: 3.825

4.  Psychophysical versus physiological spatial forward masking and the relation to speech perception in cochlear implants.

Authors:  Michelle L Hughes; Lisa J Stille
Journal:  Ear Hear       Date:  2008-06       Impact factor: 3.570

5.  Forward-masked spatial tuning curves in cochlear implant users.

Authors:  David A Nelson; Gail S Donaldson; Heather Kreft
Journal:  J Acoust Soc Am       Date:  2008-03       Impact factor: 1.840

6.  Effects of Stimulus Polarity and Artifact Reduction Method on the Electrically Evoked Compound Action Potential.

Authors:  Michelle L Hughes; Jenny L Goehring; Jacquelyn L Baudhuin
Journal:  Ear Hear       Date:  2017 May/Jun       Impact factor: 3.570

7.  Current focusing and steering: modeling, physiology, and psychophysics.

Authors:  Ben H Bonham; Leonid M Litvak
Journal:  Hear Res       Date:  2008-04-06       Impact factor: 3.208

8.  Spatial tuning curves from apical, middle, and basal electrodes in cochlear implant users.

Authors:  David A Nelson; Heather A Kreft; Elizabeth S Anderson; Gail S Donaldson
Journal:  J Acoust Soc Am       Date:  2011-06       Impact factor: 1.840

9.  Psychophysical and physiological measures of electrical-field interaction in cochlear implants.

Authors:  Michelle L Hughes; Lisa J Stille
Journal:  J Acoust Soc Am       Date:  2009-01       Impact factor: 1.840

10.  Comparison of electrically evoked compound action potential thresholds and loudness estimates for the stimuli used to program the Advanced Bionics cochlear implant.

Authors:  Eun Kyung Jeon; Carolyn J Brown; Christine P Etler; Sara O'Brien; Li-Kuei Chiou; Paul J Abbas
Journal:  J Am Acad Audiol       Date:  2010-01       Impact factor: 1.664

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.