Literature DB >> 12062728

Relation of stent design and stent surface material to subsequent in-stent intimal hyperplasia in coronary arteries determined by intravascular ultrasound.

Rainer Hoffmann1, Gary S Mintz, Philipp K Haager, Togul Bozoglu, Eberhard Grube, Michael Gross, Christian Beythien, Harald Mudra, Jürgen vom Dahl, Peter Hanrath.   

Abstract

A variety of different stent designs and coatings have become available. This study sought to determine the impact of stent design and gold-coating of stents on intimal hyperplasia (IH) in human atherosclerotic coronary arteries in relation to known predictors of restenosis. Angiographic and intravascular ultrasound (IVUS) studies were performed at 6-month follow-up on 311 native coronary lesions of 311 patients treated with 99 Multi-Link stents, 74 InFlow steel stents, 73 InFlow gold-coated stents, 41 Palmaz-Schatz stents, 12 NIR steel stents, and 12 gold-coated NIR Royal stents. Lumen and stent cross-sectional area (CSA) were measured at 1-mm axial increments. Mean IH CSA (stent CSA - lumen CSA) and mean IH thickness were calculated and averaged over the total stent length. IVUS demonstrated different levels of IH for the 6 stents. Mean IH thickness ranged from 0.20 +/- 0.13 mm for Multi-Link stents to 0.43 +/- 0.14 mm for InFlow goal-coated stents (p <0.001). Multivariate analysis proved non-Multi-Link stent design (odds ratio 3.45, 95% confidence intervals 1.13 to 11.11, p <0.034) and gold coating (odds ratio 3.78, 95% confidence intervals 1.88 to 7.54, p <0.001) to be the only independent predictors of IH thickness >0.3 mm. In conclusion, stent design and surface material have an important impact on the IH response to stents implanted in human coronary arteries. However, the differences in IH thickness between the analyzed stents were relatively small compared with the absolute lumen dimensions.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12062728     DOI: 10.1016/s0002-9149(02)02347-0

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  10 in total

1.  One-year clinical follow-up of a registry evaluating a percutaneous revascularisation strategy combining a pre-specified simple selection process with the use of a new thin-strut bare cobalt-chromium stent.

Authors:  P R Stella; G Pavlakis; P Agostoni; H M Nathoe; S Hoseyni Guyomi; B J Hamer; T X Wildbergh; P A Doevendans; E Van Belle
Journal:  Neth Heart J       Date:  2010-10       Impact factor: 2.380

2.  Cobalt-chromium stents in long lesions of large vessels: clinical and angiographic results.

Authors:  Iñigo Lozano; Carlos Cuellas; Pablo Avanzas; Armando Pérez de Prado; Concepción Suárez; Juan Rondan; Daehyun Lee; Jesus M de la Hera; Felipe Fernández; César Morís
Journal:  Tex Heart Inst J       Date:  2011

Review 3.  Coronary stents: in these days of climate change should all stents wear coats?

Authors:  R Lowe; I B A Menown; G Nogareda; I M Penn
Journal:  Heart       Date:  2005-06       Impact factor: 5.994

Review 4.  Coronary artery stents: identification and evaluation.

Authors:  J Butany; K Carmichael; S W Leong; M J Collins
Journal:  J Clin Pathol       Date:  2005-08       Impact factor: 3.411

5.  First in-human randomized comparison of an anodized niobium stent versus a standard stainless steel stent--an intravascular ultrasound and angiographic two-center study: the VELA study.

Authors:  F Beier; M Gyöngyösi; T Raeder; E von Eckardstein-Thumb; W Sperker; P Albrecht; C Spes; D Glogar; H Mudra
Journal:  Clin Res Cardiol       Date:  2006-07-03       Impact factor: 5.460

6.  Computational simulation methodologies for mechanobiological modelling: a cell-centred approach to neointima development in stents.

Authors:  C J Boyle; A B Lennon; M Early; D J Kelly; C Lally; P J Prendergast
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2010-06-28       Impact factor: 4.226

7.  Development of gold stents for the treatment of intracranial aneurysms: an experimental study in a canine model.

Authors:  Takashiro Ohyama; Takuji Nishide; Hiroo Iwata; Waro Taki
Journal:  AJNR Am J Neuroradiol       Date:  2004-01       Impact factor: 3.825

8.  Biodegradable polymeric stents for vascular application in a porcine carotid artery model: English version.

Authors:  S Kischkel; N Grabow; A Püschel; B Erdle; M Kabelitz; D P Martin; S F Williams; I Bombor; K Sternberg; K-P Schmitz; W Schareck; C M Bünger
Journal:  Gefasschirurgie       Date:  2015-03-18

9.  Inhibition of intimal hyperplasia in transgenic mice conditionally expressing the chemokine-binding protein M3.

Authors:  Robert Pyo; Kristian K Jensen; Maria T Wiekowski; Denise Manfra; Antonio Alcami; Mark B Taubman; Sergio A Lira
Journal:  Am J Pathol       Date:  2004-06       Impact factor: 4.307

10.  Mechanistic evaluation of long-term in-stent restenosis based on models of tissue damage and growth.

Authors:  Ran He; Liguo Zhao; Vadim V Silberschmidt; Yang Liu
Journal:  Biomech Model Mechanobiol       Date:  2020-01-07
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.