Literature DB >> 12059940

Dynamic torque and apical forces of ProFile.04 rotary instruments during preparation of curved canals.

O A Peters1, F Barbakow.   

Abstract

AIM: To analyse torque and force generated whilst shaping curved canals using rotary instruments.
METHODOLOGY: A specially designed computer-controlled testing platform was used to record events during the shaping of straight and curved canals in plastic blocks and in extracted human teeth using ProFile.04 instruments. Size 40 apical stops were prepared using crown-down, apical preparation and step-back procedures. Maximum torque, apically directed force and the numbers of revolutions were recorded at a resolution of 100 samples s-1. Load causing separation as required by the ISO 3630-1 test and cyclic fatigue was also recorded. Mean maximum scores were calculated and statistically tested using one- and two-way analyses of variance.
RESULTS: Highest and lowest torque scores were recorded, respectively, in straight canals in plastic blocks at 25 Nmm and in natural canals at 14 Nmm. Significant differences were recorded for canal type and preparation phase (P < 0.0001). Loads causing separation varied from 3.7 to 32.3 Nmm. Apically directed forces ranged from 1 to 7.5 N. Again, there were significant differences depending on canal type and preparation phase (P < 0.0001). The number of revolutions during preparation ranged from 18 to 41. Size 15, 30 and 45 ProFile.04 instruments separated after 581, 430 and 402 revolutions, respectively, in a standard cyclic fatigue test.
CONCLUSIONS: The new torque-testing platform details physical parameters during preparation of curved canals. To improve predictability, instrumentation sequences must be tested for excessively high torsional moments or forces. This study indicated that up to 10 curved canals could be safely prepared with a sequence of ProFile. 04 rotary instruments without separation due to cyclic fatigue. Efforts should continue to correlate root canal anatomy with torque and force generated during rotary root canal preparation.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12059940     DOI: 10.1046/j.0143-2885.2001.00494.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  23 in total

1.  Differences in torsional performance of single- and multiple-instrument rotary systems for glide path preparation.

Authors:  Ana Arias; Rupinderpal Singh; Ove A Peters
Journal:  Odontology       Date:  2015-02-21       Impact factor: 2.634

2.  Comparative evaluation of cyclic fatigue resistance of four different nickel-titanium rotary files with different cross-sectional designs and alloy properties.

Authors:  Mehmet Emin Kaval; Ismail Davut Capar; Hüseyin Ertas; Bilge Hakan Sen
Journal:  Clin Oral Investig       Date:  2016-07-26       Impact factor: 3.573

3.  Evaluation of deformation and fracture rates for nickel-titanium rotary instruments according to the frequency of clinical use.

Authors:  Ayça Yılmaz; Sıtkı Selçuk Gökyay; Rüştü Dağlaroğlu; Işıl Karagöz Küçükay
Journal:  Eur Oral Res       Date:  2018-05-01

4.  The Effect of Size and Taper of Apical Preparation in Reducing Intra-Canal Bacteria: A Quantitative SEM Study.

Authors:  Nahid Mohammadzadeh Akhlaghi; Nahid Rahimifard; Amirabbas Moshari; Mehdi Vatanpour; Soheila Darmiani
Journal:  Iran Endod J       Date:  2013-12-24

5.  The Effect of surface topographical changes of two different surface treatments rotary instrument.

Authors:  Nashwan-Ahmed Qaed; Bilal-Diab Mourshed; Hashem-Motahir Al-Shamiri; Nader Alaizari; Saleh-Sulaiman Alhamdah
Journal:  J Clin Exp Dent       Date:  2018-01-01

6.  Comparison of cyclic fatigue resistance of original and counterfeit rotary instruments.

Authors:  Huseyin Ertas; Ismail Davut Capar; Hakan Arslan; Ender Akan
Journal:  Biomed Eng Online       Date:  2014-05-31       Impact factor: 2.819

7.  Cyclic fatigue resistance of OneShape, Reciproc, and WaveOne: An in vitro comparative study.

Authors:  Alberto Dagna; Claudio Poggio; Riccardo Beltrami; Marco Colombo; Marco Chiesa; Stefano Bianchi
Journal:  J Conserv Dent       Date:  2014-05

8.  Wear promoted in the apical third of simulated canals after instrumentation with ProTaper universal system.

Authors:  Kathrein Tapia da Silva; Renata Grazziotin-Soares; Orlando Limongi; Luis Eduardo Duarte Irala; Alexandre Azevedo Salles
Journal:  J Appl Oral Sci       Date:  2009 Sep-Oct       Impact factor: 2.698

9.  Cyclic Fatigue Resistance and Force Generated by OneShape Instruments during Curved Canal Preparation.

Authors:  Zhuyu Wang; Wen Zhang; Xiaolei Zhang
Journal:  PLoS One       Date:  2016-08-11       Impact factor: 3.240

10.  An analysis of cyclic fatigue resistance of reciprocating instruments in different canal curvatures after immersion in sodium hypochlorite and autoclaving: An in vitro study.

Authors:  C Champa; V Divya; A Srirekha; Rupali Karale; Ashwija Shetty; Pushpalatha Sadashiva
Journal:  J Conserv Dent       Date:  2017 May-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.