Literature DB >> 12029546

Gated myocardial perfusion tomography versus gated blood pool tomography for the calculation of left ventricular volumes and ejection fraction.

Christian Vanhove1, Natasha Walgraeve, Frank De Geeter, Philippe R Franken.   

Abstract

Left ventricular (LV) volume, and not only ejection fraction (EF), is a crucial parameter for assessing the severity of cardiac disease and determining the patient's prognosis. The purpose of this study was to compare LV volumes and EF computed automatically from gated blood pool tomography (gBPT), using QUBE, and from gated myocardial perfusion tomography (gMPT), using QGS, in the same patients with a known history of myocardial infarction. The effects of the extent and severity of the myocardial perfusion defects were investigated. Thirty-seven patients were injected in a random sequence with 740 MBq of technetium-99m human serum albumin and 925 MBq of (99m)Tc-tetrofosmin, within an interval of 2 days. gBPT and gMPT were acquired on the same triple-head gamma camera using the following acquisition parameters: 360 degrees step-and shoot rotation, 32 stops (96 projections), 30 s per stop, 64x64 matrix (pixel size 5.8 mm), 8 time bins (75% forward/backward framing). Projection data were reconstructed by filtered back-projection using a Butterworth filter. LV volumes calculated from gBPT correlated well with LV volumes measured on gMPT ( r=0.93 for end-diastolic volume and 0.95 for end-systolic volume). Volumes above 200 ml, however, were substantially higher with gMPT than with gBPT. These discrepancies were related to the severity, but not the extent, of the perfusion defects. There was also good agreement between gBPT and gMPT for the LVEF ( r=0.91). On the Bland-Altman plot, no trend but a systematic error of 5.57% and a random error of 6.85% could be found. For the LVEF, the differences between the gated tomographic techniques were related neither to the extent nor to the severity of the perfusion defects. In conclusion, LV volumes and EF computed on gMPT correlated well with those measured on gBPT. Discrepancies were observed for large volumes presumably because of inaccuracies of gMPT in patients with severe perfusion defects.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12029546     DOI: 10.1007/s00259-002-0792-7

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  7 in total

1.  Comparative value of ECG-gated blood pool SPET and ECG-gated myocardial perfusion SPET in the assessment of global systolic left ventricular function.

Authors:  Doumit Daou; Didier Vilain; Patrice Colin; Rachida Lebtahi; Thierry Fourme; Carlos Coaguila; Abdel Benada; Ilana Idy-Peretti; Michel Slama; Dominique Le Guludec
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-04       Impact factor: 9.236

Review 2.  SPECT radionuclide angiography: it is time for a consensus statement.

Authors:  Doumit Daou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-11       Impact factor: 9.236

3.  Comparison of 180 degrees and 360 degrees data acquisition for determination of left ventricular function from gated myocardial perfusion tomography and gated blood pool tomography.

Authors:  Christian Vanhove; Philippe R Franken; Michel Defrise; Axel Bossuyt
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-07-10       Impact factor: 9.236

4.  Pre-chemotherapy values for left and right ventricular volumes and ejection fraction by gated tomographic radionuclide angiography using a cadmium-zinc-telluride detector gamma camera.

Authors:  Christian Haarmark; Christine Haase; Maria Maj Jensen; Bo Zerahn
Journal:  J Nucl Cardiol       Date:  2015-09-04       Impact factor: 5.952

5.  Reproducibility of left ventricular volume and ejection fraction measurements in rat using pinhole gated SPECT.

Authors:  Christian Vanhove; Tony Lahoutte; Michel Defrise; Axel Bossuyt; Philippe R Franken
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-09-15       Impact factor: 9.236

6.  Technetium-99m-labeled autologous serum albumin: a personal-exclusive source of serum component.

Authors:  Yuh-Feng Wang; Yi-Chun Chen; Dian-Kun Li; Mei-Hua Chuang
Journal:  J Biomed Biotechnol       Date:  2011-04-28

7.  Comparison of radionuclide ventriculography using SPECT and planar techniques in different cardiac conditions.

Authors:  Teresa Massardo; Rodrigo Jaimovich; Hugo Lavados; Daniela Gutiérrez; J Carlos Rodríguez; J Miguel Saavedra; Rita Alay; Héctor Gatica
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-06-20       Impact factor: 10.057

  7 in total