Literature DB >> 12009151

Characterization of a CCD-based digital x-ray imaging system for small-animal studies: properties of spatial resolution.

Fabrice Ouandji1, Eric Potter, Wei R Chen, Yuhua Li, David Tang, Hong Liu.   

Abstract

A digital x-ray imaging system was designed for small-animal studies. This system is a fiber-optics taper-coupled imaging system with two CCD arrays uniquely jointed. The x-ray source of the system has a small focal spot of 20 microm. This digital imaging system contains specially designed shelves to provide magnification levels, ranging from 1.5x to 5x. The system is characterized in terms of its properties of spatial resolution. An observer-based spatial resolution measurement was conducted with a line-pair target and a sector test pattern. The modulation transfer function of the system, with different magnifications, was studied by use of a 10-microm lead slit. The average resolutions at 50% and 5% modulations at 1x magnification were measured as 3.9 and 8.4 lp/mm, respectively, where lp indicates line pairs. With 5x magnification, the 50% and the 5% modulations provided 13.2- and 29.9-lp/mm, respectively, average spatial resolutions. The measurements showed consistency between the two individual CCD arrays; the difference in resolution between the two CCDs is less than 1%, even at high magnifications.

Mesh:

Year:  2002        PMID: 12009151     DOI: 10.1364/ao.41.002420

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  4 in total

1.  A high-precision contrast injector for small animal x-ray digital subtraction angiography.

Authors:  Ming de Lin; Lutao Ning; Cristian T Badea; Nilesh N Mistry; Yi Qi; G Allan Johnson
Journal:  IEEE Trans Biomed Eng       Date:  2008-03       Impact factor: 4.538

2.  Characterization of Continuous and Pulsed Emission modes of a Hybrid Micro Focus X-ray Source for Medical Imaging Applications.

Authors:  Muhammad U Ghani; Molly D Wong; Liqiang Ren; Di Wu; Bin Zheng; John X Rong; Xizeng Wu; Hong Liu
Journal:  Nucl Instrum Methods Phys Res A       Date:  2017-02-16       Impact factor: 1.455

3.  Using Microbubble as Contrast Agent for High-Energy X-Ray In-line Phase Contrast Imaging: Demonstration and Comparison Study.

Authors:  Di Wu; Molly Donovan Wong; Kai Yang; Aimin Yan; Yuhua Li; Laurie Fajardo; Bin Zheng; Xizeng Wu; Hong Liu
Journal:  IEEE Trans Biomed Eng       Date:  2017-08-21       Impact factor: 4.538

Review 4.  Tutorial on X-ray photon counting detector characterization.

Authors:  Liqiang Ren; Bin Zheng; Hong Liu
Journal:  J Xray Sci Technol       Date:  2018       Impact factor: 1.535

  4 in total