| Literature DB >> 12006362 |
N Wisniewski1, N Rajamand, U Adamsson, P E Lins, W M Reichert, B Klitzman, U Ungerstedt.
Abstract
The rat is commonly used to evaluate physiological responses of subcutaneous tissue to implanted devices. In vivo longevity of various devices and the biocompatibility of biomaterials depend on how adjacent tissue interacts. How closely the rat model predicts the human response has not been well characterized. The objective of this study was to compare rat and human subcutaneous foreign body responses by monitoring the biochemical environment at a polymer-tissue interface over 8 days using microdialysis. Polyamide microdialysis probes were implanted subcutaneously in humans and rats (n = 12). Daily microdialysis samples were analyzed for glucose, lactate, pyruvate, glycerol, and urea. Blood glucose was also monitored. Analyte concentrations differed significantly between rats and humans at the implant-tissue interface. There were also qualitative differences in the 8-day trends. For example, over 8 days, microdialysate glucose increased two- to fourfold in humans but decreased in rats (P < 0.001). This study reveals profound physiological differences at material-tissue interfaces in rats and humans and highlights the need for caution when extrapolating subcutaneous rat biocompatibility data to humans.Entities:
Mesh:
Substances:
Year: 2002 PMID: 12006362 DOI: 10.1152/ajpendo.00259.2001
Source DB: PubMed Journal: Am J Physiol Endocrinol Metab ISSN: 0193-1849 Impact factor: 4.310