Literature DB >> 11995426

Minimally invasive procedures. Interventional MR image-guided functional neurosurgery.

R M Chu1, R P Tummala, J Kucharczyk, C L Truwit, R E Maxwell.   

Abstract

Intraoperative MR imaging techniques have the potential to greatly improve the stereotactic methods used for functional neurosurgery. No longer are neurosurgeons and patients always constrained by uncomfortable head frames and conventional stereotaxy. Accuracy and complication avoidance are improved by intraoperative imaging. Safety of operative machinery and equipment in an MR imaging operative suite is attainable, even with deep brain stimulating electrodes in depth electrodes for epilepsy. Although cost-effectiveness remains to be determined (see article by Kucharczyk et al in this issue), the minor inconveniences of operating within an iMRI environment seem to be significantly outweighed by the benefits.

Entities:  

Mesh:

Year:  2001        PMID: 11995426

Source DB:  PubMed          Journal:  Neuroimaging Clin N Am        ISSN: 1052-5149            Impact factor:   2.264


  6 in total

Review 1.  Interventional and intraoperative MR: review and update of techniques and clinical experience.

Authors:  Thomas Schulz; Silvia Puccini; Jens-Peter Schneider; Thomas Kahn
Journal:  Eur Radiol       Date:  2004-10-06       Impact factor: 5.315

2.  Design optimization of MR-compatible rotating anode x-ray tubes for stable operation.

Authors:  Mihye Shin; Prasheel Lillaney; Waldo Hinshaw; Rebecca Fahrig
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

3.  Electrostatic focal spot correction for x-ray tubes operating in strong magnetic fields.

Authors:  Prasheel Lillaney; Mihye Shin; Waldo Hinshaw; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

4.  Magnetostatic focal spot correction for x-ray tubes operating in strong magnetic fields using iterative optimization.

Authors:  Prasheel Lillaney; Mihye Shin; Steven M Conolly; Rebecca Fahrig
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

5.  Novel motor design for rotating anode x-ray tubes operating in the fringe field of a magnetic resonance imaging system.

Authors:  Prasheel Lillaney; Mihye Shin; Waldo Hinshaw; N Robert Bennett; Norbert Pelc; Rebecca Fahrig
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

6.  Detection of infusate leakage in the brain using real-time imaging of convection-enhanced delivery.

Authors:  Vanja Varenika; Peter Dickinson; John Bringas; Richard LeCouteur; Robert Higgins; John Park; Massimo Fiandaca; Mitchel Berger; John Sampson; Krystof Bankiewicz
Journal:  J Neurosurg       Date:  2008-11       Impact factor: 5.115

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.