Improved computed radiography image quality from a BaFl:Eu photostimulable phosphor plate.

Yasushi Nakano1, Tomonori Gido, Satoshi Honda, Akihiro Maezawa, Hideaki Wakamatsu, Takafumi Yanagita.   

Abstract

Recent advances in the design of photostimulable phosphor (PSP) plates for computed radiography (CR) systems have made it possible to manufacture plates made of BaFI:Eu phosphor material in the cassette form. The image quality of this plate, six BaF(Br,I):Eu plates, and one BaFBr:Eu plate were evaluated in terms of presampling modulation transfer function (MTF), normalized Wiener spectra (WSN), and detective quantum efficiency (DQE). Compared with the best-performing BaF(Br,I):Eu plate, the BaFI:Eu plate provided DQE that was higher, at spatial frequencies of 0.5, 1.0, and 2.0 cycles/mm, by 12% (21.8 versus 19.4), 13% (18.8 versus 16.7), and 11% (12.0 versus 10.8), respectively. Since presampling MTF values of the two plates were comparable, the BaFI:Eu plate's higher DQE is attributable to total WSN conversely being lower by 17% [8.65 x 10(-5) (mm2) versus 10.38 x 10(-5) (mm2)], 17% [5.85 x 10(-5) (mm2) versus 7.03 x 10(-5) (mm2)], and 12% [2.82 x 10(-5) (mm2) versus 3.19 x 10(-5) (mm2)] at the specified frequencies, respectively, primarily due to the contribution of x-ray quantum WSN. This jibes with the high x-ray absorption provided by the 27%-higher x-ray attenuation coefficients (7.54 versus 6.07, at 60 KeV) that BaFI offers over BaF(Br(0.85),I(0.15)), a result of the high atomic number of BaFI's exclusively iodine halide content. The results were consistent with earlier studies of several of these same plates and indicate that BaFI:Eu is a promising avenue to lower image noise and higher overall CR system image quality.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11991131     DOI: 10.1118/1.1462639

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Automated recognition of lateral from PA chest radiographs: saving seconds in a PACS environment.

Authors:  John M Boone; Greg S Hurlock; J Anthony Seibert; Richard L Kennedy
Journal:  J Digit Imaging       Date:  2004-01-30       Impact factor: 4.056

Review 2.  Digital detectors for mammography: the technical challenges.

Authors:  A Noel; F Thibault
Journal:  Eur Radiol       Date:  2004-10-08       Impact factor: 5.315

3.  Flat detectors and their clinical applications.

Authors:  Martin Spahn
Journal:  Eur Radiol       Date:  2005-04-02       Impact factor: 5.315

4.  Modeling the performance characteristics of computed radiography (CR) systems.

Authors:  Srinivasan Vedantham; Andrew Karellas
Journal:  IEEE Trans Med Imaging       Date:  2010-03       Impact factor: 10.048

5.  Performance evaluation of three computed radiography systems using methods recommended in American Association of Physicists in Medicine Report 93.

Authors:  Wilbroad Muhogora; Renato Padovani; Faustino Bonutti; Peter Msaki; R Kazema
Journal:  J Med Phys       Date:  2011-07

Review 6.  Storage Phosphors for Medical Imaging.

Authors:  Paul Leblans; Dirk Vandenbroucke; Peter Willems
Journal:  Materials (Basel)       Date:  2011-06-09       Impact factor: 3.623