Literature DB >> 11990834

Anterior cervical fusion with carbon fiber cage containing coralline hydroxyapatite: preliminary observations in 45 consecutive cases of soft-disc herniation.

Umberto Agrillo1, Luciano Mastronardi, Fabrizio Puzzilli.   

Abstract

OBJECT: The purposes of bone substitutes for anterior cervical fusion (ACF) are immediate biomechanical support and osteointegration of the graft. The authors report their preliminary results in performing ACF in which carbon fiber cages (CFCs) containing coralline hydroxyapatite (HA) are used as bone substitute.
METHODS: During a 24-month period, anterior microsurgical discectomy was performed in 45 consecutive patients for soft-disc cervical herniation. In all cases ACF was performed using a CFC containing a core of granulated coralline HA. Fifty-seven CFCs were implanted in 33 single-level and 12 two-level procedures. The mean operative time was 83 minutes for one-level and 97 minutes for two-level procedures. The mean hospital stay was 1.51 days, and there were no permanent complications. At a mean follow up of 22.3 months, the pain had decreased or disappeared in all patients, and the patients' satisfaction rate was very high. Good results were also obtained in patients who smoked cigarettes. Patients underwent radiographic evaluation at Day 1, and 1, 3, 6, and 12 months postoperatively. Implant-related complications were not observed and revision surgeries were not performed. Twelve-month cervical x-ray films demonstrated complete fusion in all cases, without evidence of breakage, collapse, pseudarthrosis, subsidence, angular deformity, or protrusion. Signs of pathological absorption and necrosis were not found in contiguous vertebral bodies, and inflammatory reactions were never seen around cages.
CONCLUSIONS: These preliminary results suggest that implants composed of CFC containing granulated coralline HA are promising bone substitutes to be used in ACF, with a good rate of incorporation and no significant complications.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11990834     DOI: 10.3171/spi.2002.96.3.0273

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  18 in total

1.  Can an Endplate-conformed Cervical Cage Provide a Better Biomechanical Environment than a Typical Non-conformed Cage?: A Finite Element Model and Cadaver Study.

Authors:  Fan Zhang; Hao-Cheng Xu; Bo Yin; Xin-Lei Xia; Xiao-Sheng Ma; Hong-Li Wang; Jun Yin; Ming-Hao Shao; Fei-Zhou Lyu; Jian-Yuan Jiang
Journal:  Orthop Surg       Date:  2016-08       Impact factor: 2.071

2.  Anterior cervical interbody fusion with the Zero-P spacer: mid-term results of two-level fusion.

Authors:  Yuanyuan Chen; Huajing Chen; Peng Cao; Wen Yuan
Journal:  Eur Spine J       Date:  2015-04-08       Impact factor: 3.134

3.  Implantation of an empty polyetheretherketone cage in anterior cervical discectomy and fusion: a prospective randomised controlled study with 2 years follow-up.

Authors:  Shang-Wen Feng; Ming-Chau Chang; Po-Hsin Chou; Hsi-Hsien Lin; Shih-Tien Wang; Chien-Lin Liu
Journal:  Eur Spine J       Date:  2018-01-10       Impact factor: 3.134

4.  Anterior cervical fusion for radicular-disc conflict performed by three different procedures: clinical and radiographic analysis at long-term follow-up.

Authors:  A Zagra; L Zagra; L Scaramuzzo; L Minoia; M Archetti; F Giudici
Journal:  Eur Spine J       Date:  2013-09-27       Impact factor: 3.134

5.  A prospective randomized study comparing a cervical carbon fiber cage to the Smith-Robinson technique with allograft and plating: up to 24 months follow-up.

Authors:  Stephen I Ryu; Michelle Mitchell; Daniel H Kim
Journal:  Eur Spine J       Date:  2005-06-25       Impact factor: 3.134

6.  Effect of hydroxyapatite on bone integration in a rabbit tibial defect model.

Authors:  Myung-Jin Lee; Sung-Keun Sohn; Kyung-Taek Kim; Chul-Hong Kim; Hee-Bae Ahn; Mee-Sook Rho; Min-Ho Jeong; Sang-Kyu Sun
Journal:  Clin Orthop Surg       Date:  2010-05-04

Review 7.  Zero-P: a new zero-profile cage-plate device for single and multilevel ACDF. A single institution series with four years maximum follow-up and review of the literature on zero-profile devices.

Authors:  Giuseppe M V Barbagallo; Dario Romano; Francesco Certo; Pietro Milone; Vincenzo Albanese
Journal:  Eur Spine J       Date:  2013-09-24       Impact factor: 3.134

8.  Comparison of outcomes and safety of using hydroxyapatite granules as a substitute for autograft in cervical cages for anterior cervical discectomy and interbody fusion.

Authors:  Hosein Mashhadinezhad; Fariborz Samini; Reza Zare
Journal:  Arch Bone Jt Surg       Date:  2014-03-15

9.  Anterior cervical fusion with interbody cage containing beta-tricalcium phosphate augmented with plate fixation: a prospective randomized study with 2-year follow-up.

Authors:  Li-Yang Dai; Lei-Sheng Jiang
Journal:  Eur Spine J       Date:  2008-02-27       Impact factor: 3.134

Review 10.  Bone graft substitutes in anterior cervical discectomy and fusion.

Authors:  Anthony M T Chau; Ralph J Mobbs
Journal:  Eur Spine J       Date:  2009-01-17       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.