| Literature DB >> 11969328 |
Jesper L R Andersson1, Stefan Skare.
Abstract
The self-diffusion tensor may be calculated from several echo-planar image acquisitions preceded by different diffusion gradients. Unfortunately, these diffusion gradients cause geometric distortion that must be corrected before estimation of the tensor. In the present paper we suggest and implement a method for retrospective correction of these distortions firmly based on a physical model for the diffusion-weighted images. This method simultaneously estimates subject movement and distortion parameters by finding the set of parameters that minimizes residual error when fitting data to the diffusion tensor model. We show how this notion can be formalized as a quadratic form thereby facilitating the implementation of a rapid algorithm. In addition, we suggest models for how distortions vary with slice position and gradient direction that allow us to substantially reduce the dimensionality of the parameter space. Our results indicate that we are able to estimate both eddy current-induced distortion and subject movement directly from the data without need of any additional measurements. 2002 Elsevier Science (USA).Entities:
Mesh:
Year: 2002 PMID: 11969328 DOI: 10.1006/nimg.2001.1039
Source DB: PubMed Journal: Neuroimage ISSN: 1053-8119 Impact factor: 6.556