Literature DB >> 11948060

Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients.

Thierry Boulain1, Jean-Michel Achard, Jean-Louis Teboul, Christian Richard, Dominique Perrotin, Guy Ginies.   

Abstract

OBJECTIVE: To test the hypothesis that passive leg raising (PLR) induces changes in arterial pulse pressure that can help to predict the response to rapid fluid loading (RFL) in patients with acute circulatory failure who are receiving mechanical ventilation.
DESIGN: Prospective clinical study.
SETTING: Two medical ICUs in university hospitals. PATIENTS: Thirty-nine patients with acute circulatory failure who were receiving mechanical ventilation and had a pulmonary artery catheter in place.
INTERVENTIONS: PLR for > 4 min and a subsequent 300-mL RFL for > 20 min.
MEASUREMENTS AND MAIN RESULTS: Radial artery pulse pressure (PPrad), heart rate, right atrial pressure, pulmonary artery occlusion pressure (PAOP), and cardiac output were measured invasively in a population of 15 patients at each phase of the study procedure (i.e., before and during PLR, and then before and after RFL). PPrad, PAOP, and stroke volume (SV) significantly increased in patients performing PLR. These changes were rapidly reversible when the patients' legs were lowered. Changes in PPrad during PLR were significantly correlated with changes in SV during PLR (r = 0.77; p < 0.001). Changes in SV induced by PLR and by RFL were significantly correlated (r = 0.89; p < 0.001). Finally, PLR-induced changes in PPrad were significantly correlated to RFL-induced changes in SV (r = 0.84; p < 0.001). In a second population of 24 patients, we found the same relationship between PLR-induced changes in PPrad and RFL-induced changes in SV (r = 0.73; p < 0.001).
CONCLUSION: The response to RFL could be predicted noninvasively by a simple observation of changes in pulse pressure during PLR in patients with acute circulatory failure who were receiving mechanical ventilation.

Entities:  

Mesh:

Year:  2002        PMID: 11948060     DOI: 10.1378/chest.121.4.1245

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  64 in total

Review 1.  Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies.

Authors:  Fabio Cavallaro; Claudio Sandroni; Cristina Marano; Giuseppe La Torre; Alice Mannocci; Chiara De Waure; Giuseppe Bello; Riccardo Maviglia; Massimo Antonelli
Journal:  Intensive Care Med       Date:  2010-05-26       Impact factor: 17.440

Review 2.  Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis.

Authors:  Xavier Monnet; Paul Marik; Jean-Louis Teboul
Journal:  Intensive Care Med       Date:  2016-01-29       Impact factor: 17.440

Review 3.  Understanding the passive leg raising test.

Authors:  Anders Aneman; Soren Sondergaard
Journal:  Intensive Care Med       Date:  2016-02-03       Impact factor: 17.440

4.  Hemodynamic effects of passive leg raising: an echocardiographic study in patients with shock.

Authors:  Vincent Caille; Julien Jabot; Guillaume Belliard; Cyril Charron; François Jardin; Antoine Vieillard-Baron
Journal:  Intensive Care Med       Date:  2008-03-20       Impact factor: 17.440

5.  Can one predict fluid responsiveness in spontaneously breathing patients?

Authors:  Daniel De Backer; Michael R Pinsky
Journal:  Intensive Care Med       Date:  2007-05-17       Impact factor: 17.440

Review 6.  A definition of normovolaemia and consequences for cardiovascular control during orthostatic and environmental stress.

Authors:  Jasper Truijen; Morten Bundgaard-Nielsen; Johannes J van Lieshout
Journal:  Eur J Appl Physiol       Date:  2010-01-07       Impact factor: 3.078

Review 7.  Advanced hemodynamic monitoring: principles and practice in neurocritical care.

Authors:  Christos Lazaridis
Journal:  Neurocrit Care       Date:  2012-02       Impact factor: 3.210

8.  Combined analysis of cardiac output and CVP changes remains the best way to titrate fluid administration in shocked patients.

Authors:  Fabrice Vallée; Arnaud Mari; Anders Perner; Benoît Vallet
Journal:  Intensive Care Med       Date:  2010-03-11       Impact factor: 17.440

9.  The passive leg raise test to predict fluid responsiveness in children--preliminary observations.

Authors:  Guo-ping Lu; Gangfeng Yan; Yang Chen; Zhu-jin Lu; Lin-en Zhang; Niranjan Kissoon
Journal:  Indian J Pediatr       Date:  2013-12-11       Impact factor: 1.967

10.  A severe case of vasoplegic shock following metformin overdose successfully treated with methylene blue as a last line therapy.

Authors:  Rachel Erin Graham; Michaela Cartner; James Winearls
Journal:  BMJ Case Rep       Date:  2015-07-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.