Literature DB >> 11937873

Fluoroscopy-based multiplanar image guidance for insertion of sacroiliac screws.

A F Hinsche1, P V Giannoudis, R M Smith.   

Abstract

A prospective controlled experimental study was done to assess the value of fluoroscopy-based, computer-assisted orthopaedic surgery for the insertion of sacroiliac screws and to compare this new technology with the conventional technique, using image intensification. In a simulated surgical setup, 140 cannulated screws were placed into the S1 and S2 vertebral bodies of 35 pelvic models. The screws were inserted under fluoroscopy-based image guidance or with the conventional technique. Different drills were tested with both techniques, including a 2.8-mm guide wire and a 5-mm solid drill. The 2.8-mm guide wire proved inaccurate with the computer-assisted image guidance system because of guide wire flexibility. Using the more rigid 5-mm drill, the results of computer-assisted image guidance were comparable with the image intensifier technique. The radiation exposure during screw insertion was reduced considerably when using the image guidance system. System-specific requirements warranted adjustment of surgical technique and instruments. The major advantages of this new technology are immediate intraoperative image acquisition and provision of surgical guidance in as much as four planes simultaneously. The results of this experimental study are encouraging and have led to initiation of a clinical trial.

Entities:  

Mesh:

Year:  2002        PMID: 11937873     DOI: 10.1097/00003086-200202000-00014

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  30 in total

1.  Factors influencing the accuracy of iliosacral screw placement in trauma patients.

Authors:  Lars Grossterlinden; Johannes Rueger; Philip Catala-Lehnen; Martin Rupprecht; Wolfgang Lehmann; Andreas Rücker; Daniel Briem
Journal:  Int Orthop       Date:  2010-07-20       Impact factor: 3.075

2.  Precision insertion of percutaneous sacroiliac screws using a novel augmented reality-based navigation system: a pilot study.

Authors:  Huixiang Wang; Fang Wang; Anthony Peng Yew Leong; Lu Xu; Xiaojun Chen; Qiugen Wang
Journal:  Int Orthop       Date:  2015-11-16       Impact factor: 3.075

3.  Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure.

Authors:  Jörn Zwingmann; Gerhard Konrad; Elmar Kotter; Norbert P Südkamp; Michael Oberst
Journal:  Clin Orthop Relat Res       Date:  2008-11-26       Impact factor: 4.176

4.  Biomechanical comparison of three types of internal fixation in a type C zone II pelvic fracture model.

Authors:  Tao Wu; Wei Chen; Xu Li; Qi Zhang; Hong-Zhi Lv; Ying-Ze Zhang
Journal:  Int J Clin Exp Med       Date:  2015-02-15

5.  Bowel preparation prior to percutaneous ilio-sacral screw insertion: is it necessary?

Authors:  H Raza; A Bowe; N Davarinos; M Leonard
Journal:  Eur J Trauma Emerg Surg       Date:  2016-07-04       Impact factor: 3.693

6.  Therapeutic effects of minimally invasive adjustable and locking compression plate for unstable pelvic fractures via posterior approach.

Authors:  Tao Wu; Wei Chen; Qi Zhang; Xu Li; Hong-Zhi Lv; Guang Yang; Ying-Ze Zhang
Journal:  Int J Clin Exp Med       Date:  2015-01-15

7.  [Percutaneous sacroiliac lag screw fixation of the posterior pelvic ring. Increasing safety by standardization of visualization and insertion technique].

Authors:  G Tosounidis; U Culemann; R Wirbel; J H Holstein; T Pohlemann
Journal:  Unfallchirurg       Date:  2007-08       Impact factor: 1.000

8.  Technical and clinical outcome of percutaneous CT fluoroscopy-guided screw placement in unstable injuries of the posterior pelvic ring.

Authors:  Frederik F Strobl; Sophia M Haeussler; Philipp M Paprottka; Ralf-Thorsten Hoffmann; Oliver Pieske; Maximilian F Reiser; Christoph G Trumm
Journal:  Skeletal Radiol       Date:  2014-05-10       Impact factor: 2.199

9.  2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries--a case series.

Authors:  Florian Gras; Ivan Marintschev; Arne Wilharm; Kajetan Klos; Thomas Mückley; Gunther O Hofmann
Journal:  BMC Musculoskelet Disord       Date:  2010-07-07       Impact factor: 2.362

10.  Outcome of long-axis percutaneous sacroplasty for the treatment of sacral insufficiency fractures.

Authors:  Ehab M Kamel; Stefano Binaghi; Daniel Guntern; Elyazid Mouhsine; Pierre Schnyder; Nicolas Theumann
Journal:  Eur Radiol       Date:  2009-12       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.