BACKGROUND: In recent years, the closed reduction and percutaneous fixation of posterior pelvic ring fractures by sacroiliac screws has become a well established treatment option for stabilization of posterior pelvic ring disruptions. Stable percutaneous pelvic ring fixation also implies a very low complication rate, e.g., in operative blood loss, wound healing, and operative time. To avoid malpositioning of the screws, sufficient reduction and radiologic visualization are essential. The surgical technique has been described in several studies; however, great importance is attached to the personal experience of the surgeon. Therefore, this study was conducted to establish a standard procedure that allows different surgeons a safe positioning of sacroiliac screws.
RESULTS: A total of 41 injuries of the posterior pelvic ring were stabilized with 73 sacroiliac lag screws inserted by 7 different surgeons using a standardized technique. In all cases adequate reduction of the fracture and radiologic visualization were achieved. No wound infections, no relevant bleedings, and no spiral fractures of screws were observed. In two cases malpositioning led to revision of the screws. Of interest, one case of S1 paresthesia resulting from a malpositioned screw could be revised. In contrast, two cases of screw loosening and one case of screw bending did not require further intervention.
CONCLUSION: We conclude that safe positioning of the sacroiliac screws was accomplished by all surgeons given a standardized technique. For safe insertion preparation of the patients, accurate visualization of the fracture zone, and potential closed reduction is always required.

Entities:  

Mesh:

Year:  2007        PMID: 17572870     DOI: 10.1007/s00113-007-1270-2

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  9 in total

Review 1.  [Technique for percutaneous iliosacral screw insertion with conventional C-arm radiography].

Authors:  R E Hilgert; J Finn; H-J Egbers
Journal:  Unfallchirurg       Date:  2005-11       Impact factor: 1.000

2.  [Computer-assisted screw placement into the posterior pelvic ring: assessment of different navigated procedures in a cadaver trial].

Authors:  D Briem; J M Rueger; P G C Begemann; Z Halata; T Bock; W Linhart; J Windolf
Journal:  Unfallchirurg       Date:  2006-08       Impact factor: 1.000

3.  Internal fixation of pelvic ring fractures.

Authors:  J M Matta; T Saucedo
Journal:  Clin Orthop Relat Res       Date:  1989-05       Impact factor: 4.176

Review 4.  [Determining indications and osteosynthesis techniques for the pelvic girdle].

Authors:  T Pohlemann; A Gänsslen; B Kiessling; U Bosch; N Haas; H Tscherne
Journal:  Unfallchirurg       Date:  1992-04       Impact factor: 1.000

5.  Iliosacral screw fixation: early complications of the percutaneous technique.

Authors:  M L Routt; P T Simonian; W J Mills
Journal:  J Orthop Trauma       Date:  1997-11       Impact factor: 2.512

6.  Fluoroscopy-based multiplanar image guidance for insertion of sacroiliac screws.

Authors:  A F Hinsche; P V Giannoudis; R M Smith
Journal:  Clin Orthop Relat Res       Date:  2002-02       Impact factor: 4.176

7.  Fluoroscopic positioning of sacroiliac screws in 88 patients.

Authors:  Eric W van den Bosch; C Marieke A van Zwienen; Arie B van Vugt
Journal:  J Trauma       Date:  2002-07

8.  Percutaneous iliosacral screw fixation: early treatment for unstable posterior pelvic ring disruptions.

Authors:  T E Shuler; D C Boone; G S Gruen; A B Peitzman
Journal:  J Trauma       Date:  1995-03

9.  Early results of percutaneous iliosacral screws placed with the patient in the supine position.

Authors:  M L Routt; P J Kregor; P T Simonian; K A Mayo
Journal:  J Orthop Trauma       Date:  1995-06       Impact factor: 2.512

  9 in total
  8 in total

1.  Evaluation of 2D and 3D navigation for iliosacral screw fixation.

Authors:  Daniel Behrendt; Maria Mütze; Hanno Steinke; Martin Koestler; Christoph Josten; Jörg Böhme
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-09-18       Impact factor: 2.924

Review 2.  [Concept for treatment of pelvic ring injuries in elderly patients. A challenge].

Authors:  U Culemann; A Scola; G Tosounidis; T Pohlemann; F Gebhard
Journal:  Unfallchirurg       Date:  2010-04       Impact factor: 1.000

3.  Trans-iliac-sacral-iliac-bar procedure to treat insufficiency fractures of the sacrum.

Authors:  P Vanderschot; M Kuppers; A Sermon; L Lateur
Journal:  Indian J Orthop       Date:  2009-07       Impact factor: 1.251

4.  [Current treatment of pelvic ring fractures].

Authors:  U Culemann; H J Oestern; T Pohlemann
Journal:  Unfallchirurg       Date:  2014-02       Impact factor: 1.000

5.  [Variability of the screw position after 3D-navigated sacroiliac screw fixation. Influence of the surgeon's experience with the navigation technique].

Authors:  G Konrad; J Zwingmann; E Kotter; N Südkamp; M Oberst
Journal:  Unfallchirurg       Date:  2010-01       Impact factor: 1.000

Review 6.  [Current treatment of pelvic ring fractures].

Authors:  U Culemann; H J Oestern; T Pohlemann
Journal:  Chirurg       Date:  2013-09       Impact factor: 0.955

7.  [Minimally invasive fixation of a sacral bilateral fracture with lumbopelvic dissociation].

Authors:  T Mendel; P Kuhn; D Wohlrab; K Brehme
Journal:  Unfallchirurg       Date:  2009-06       Impact factor: 1.000

8.  Minimally invasive posterior locked compression plate osteosynthesis shows excellent results in elderly patients with fragility fractures of the pelvis.

Authors:  Imke U Schmerwitz; Philipp Jungebluth; Wolfgang Lehmann; Thomas J Hockertz
Journal:  Eur J Trauma Emerg Surg       Date:  2020-10-26       Impact factor: 3.693

  8 in total