Literature DB >> 11916276

Approved IFCC reference method for the measurement of HbA1c in human blood.

Jan-Olof Jeppsson1, Uwe Kobold, John Barr, Andreas Finke, Wieland Hoelzel, Tadao Hoshino, Kor Miedema, Andrea Mosca, Pierluigi Mauri, Rita Paroni, Linda Thienpont, Masao Umemoto, Cas Weykamp.   

Abstract

HbA1C is the stable glucose adduct to the N-terminal group of the beta-chain of HbA0. The measurement of HbA1c in human blood is most important for the long-term control of the glycaemic state in diabetic patients. Because there was no internationally agreed reference method the IFCC Working Group on HbA1c Standardization developed a reference method which is here described. In a first step haemoglobin is cleaved into peptides by the enzyme endoproteinase Glu-C, and in a second step the glycated and non-glycated N-terminal hexapeptides of the beta-chain obtained are separated and quantified by HPLC and electrospray ionisation mass spectrometry or in a two-dimensional approach using HPLC and capillary electrophoresis with UV-detection. Both principles give identical results. HbA1c is measured as ratio between the glycated and non-glycated hexapeptides. Calibrators consisting of mixtures of highly purified HbA1c and HbA0 are used. The analytical performance of the reference method has been evaluated by an international network of reference laboratories comprising laboratories from Europe, Japan and the USA. The intercomparison studies of the network showed excellent results with intra-laboratory CVs of 0.5 to 2% and inter-laboratory CVs of 1.4 to 2.3%. Possible interferences have been carefully investigated. Due to the higher specificity of the reference method the results are lower than those generated with most of the present commercial methods which currently are calibrated with unspecific designated comparison methods. The new reference method has been approved by the member societies of the International Federation of Clinical Chemistry and Laboratory Medicine and will be the basis for the future uniform standardization of HbA1c routine assays worldwide.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11916276     DOI: 10.1515/CCLM.2002.016

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  118 in total

1.  HbA1c measurement.

Authors:  E S Kilpatrick
Journal:  J Clin Pathol       Date:  2004-04       Impact factor: 3.411

2.  The effect of increased fetal hemoglobin on 7 common Hb A1c assay methods.

Authors:  Randie R Little; Curt L Rohlfing; Steven E Hanson; Robert L Schmidt; Chia-Ni Lin; Richard W Madsen; William L Roberts
Journal:  Clin Chem       Date:  2012-02-22       Impact factor: 8.327

3.  Correlation of the serum insulin and the serum uric Acid levels with the glycated haemoglobin levels in the patients of type 2 diabetes mellitus.

Authors:  Anju Gill; Sahiba Kukreja; Naresh Malhotra; Namrata Chhabra
Journal:  J Clin Diagn Res       Date:  2013-05-11

4.  How should HbA1c measurements be reported?

Authors:  F Gorus; C Mathieu; E Gerlo
Journal:  Diabetologia       Date:  2006-01       Impact factor: 10.122

Review 5.  Candidate-based proteomics in the search for biomarkers of cardiovascular disease.

Authors:  Leigh Anderson
Journal:  J Physiol       Date:  2004-12-20       Impact factor: 5.182

Review 6.  Disorders of glucose metabolism-post mortem analyses in forensic cases: part I.

Authors:  Cornelius Hess; Frank Musshoff; Burkhard Madea
Journal:  Int J Legal Med       Date:  2010-09-29       Impact factor: 2.686

7.  Traceability, reference systems and result comparability.

Authors:  Mauro Panteghini
Journal:  Clin Biochem Rev       Date:  2007-08

8.  Consensus statement on the worldwide standardisation of the HbA1c measurement.

Authors: 
Journal:  Diabetologia       Date:  2007-08-22       Impact factor: 10.122

9.  Comparison of Arkray/ELITech ADAMS HA-8180V with Bio-Rad Variant, II Turbo2.0 and Tosoh Bioscience HLC-723G8 for HbA1c determination.

Authors:  Stéphanie Badiou; Julie Guillot; Nils Kuster; Anne-Sophie Bargnoux; Patricia Aguilar-Martinez; Elodie Boissier; Jean-Paul Cristol; Anne-Marie Dupuy
Journal:  J Clin Lab Anal       Date:  2014-03-20       Impact factor: 2.352

10.  Towards worldwide standardisation of HbA1c determination.

Authors:  K Miedema
Journal:  Diabetologia       Date:  2004-07-13       Impact factor: 10.122

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.