Literature DB >> 11888957

Sleep structure correlates of continuous positive airway pressure variations during application of an autotitrating continuous positive airway pressure machine in patients with obstructive sleep apnea syndrome.

Oreste Marrone1, Giuseppe Insalaco, Maria Rosaria Bonsignore, Salvatore Romano, Adriana Salvaggio, Giovanni Bonsignore.   

Abstract

STUDY
OBJECTIVES: To evaluate the relationship between sleep structure and continuous positive airway pressure (CPAP) delivered by an automatic CPAP (auto-CPAP) machine in patients with obstructive sleep apnea syndrome (OSAS).
DESIGN: Nocturnal polysomnography was performed during CPAP administration by an auto-CPAP machine (Autoset Clinical 1; ResMed; Sydney, Australia).
SETTING: Sleep-disorders center in a research institute. PATIENTS: Fifteen subjects with newly diagnosed OSAS deserving home CPAP treatment. MEASUREMENTS AND
RESULTS: During the night, in most cases, the lowest CPAP level was recorded during a prolonged nonrapid eye movement (NREM) sleep period uninterrupted by arousals, whereas the highest level during wake-sleep transitions or NREM sleep fragmented by arousals. In four subjects, rapid eye movement sleep was always associated with increasing CPAP. Sleep efficiency was negatively correlated with CPAP variability, evaluated as the SD of the mean nocturnal CPAP level averaged epoch by epoch (r = 0.63, p < 0.02). Eighty-eight percent of rapid CPAP augmentations (increases by at least 2 cm H(2)O in less-than-or-equal 2 min) were observed during sleep-wake transitions or after arousals/awakenings (Ar/Aw); 63% of such Ar/Aw were not preceded by any detectable respiratory abnormality.
CONCLUSIONS: CPAP levels and variations during auto-CPAP application may be mainly related to sleep continuity and efficiency. The recording of a highly variable pressure during auto-CPAP administration in an unattended environment must raise the question whether the patient's sleep quality was acceptable. A poor sleep quality during an autotitration night could lead to an undesirable overestimation of the CPAP level needed for use with fixed-level CPAP machines.

Entities:  

Mesh:

Year:  2002        PMID: 11888957     DOI: 10.1378/chest.121.3.759

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  14 in total

1.  Are home ventilators able to guarantee a minimal tidal volume?

Authors:  Brigitte Fauroux; Karl Leroux; Jean-Louis Pépin; Frédéric Lofaso; Bruno Louis
Journal:  Intensive Care Med       Date:  2010-03-09       Impact factor: 17.440

2.  Equivalence of nasal and oronasal masks during initial CPAP titration for obstructive sleep apnea syndrome.

Authors:  Ming Teo; Terence Amis; Sharon Lee; Karina Falland; Stephen Lambert; John Wheatley
Journal:  Sleep       Date:  2011-07-01       Impact factor: 5.849

3.  Multinight recording and analysis of continuous positive airway pressure airflow in the home for titration and management of sleep disordered breathing.

Authors:  Cynthia Y Callahan; Robert G Norman; Zachary Taxin; Anne M Mooney; David M Rapoport; Indu Ayappa
Journal:  Sleep       Date:  2013-04-01       Impact factor: 5.849

4.  A new animal model of obstructive sleep apnea responding to continuous positive airway pressure.

Authors:  Pierre-Charles Neuzeret; Frédéric Gormand; Philippe Reix; Sandrine Parrot; Jean-Pierre Sastre; Colette Buda; Gérard Guidon; Kazuya Sakai; Jian-Sheng Lin
Journal:  Sleep       Date:  2011-04-01       Impact factor: 5.849

5.  Validation of the System One RemStar Auto A-Flex for Obstructive Sleep Apnea Treatment and Detection of Residual Apnea-Hypopnea Index: A European Randomized Trial.

Authors:  Frédéric Gagnadoux; Dirk Pevernagie; Poul Jennum; Nina Lon; Corinne Loiodice; Renaud Tamisier; Petra van Mierlo; Wojciech Trzepizur; Martina Neddermann; Annika Machleit; Jeffrey Jasko; Jean Louis Pépin
Journal:  J Clin Sleep Med       Date:  2017-02-15       Impact factor: 4.062

6.  A longitudinal study of the accuracy of positive airway pressure therapy machine-detected apnea-hypopnea events.

Authors:  Yue-Nan Ni; Robert Joseph Thomas
Journal:  J Clin Sleep Med       Date:  2022-04-01       Impact factor: 4.062

Review 7.  APAP, BPAP, CPAP, and New Modes of Positive Airway Pressure Therapy.

Authors:  Karin G Johnson
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 3.650

8.  Adaptive servo-ventilation therapy of central sleep apnoea and its effect on sleep quality.

Authors:  Andrea Hetzenecker; Tatjana Roth; Christoph Birner; Lars S Maier; Michael Pfeifer; Michael Arzt
Journal:  Clin Res Cardiol       Date:  2015-09-05       Impact factor: 5.460

Review 9.  Adherence to continuous positive airway pressure therapy: the challenge to effective treatment.

Authors:  Terri E Weaver; Ronald R Grunstein
Journal:  Proc Am Thorac Soc       Date:  2008-02-15

10.  Autoadjusting-CPAP effect on serum leptin concentrations in obstructive sleep apnoea patients.

Authors:  Marta Drummond; João C Winck; João T Guimarães; Ana C Santos; João Almeida; José A Marques
Journal:  BMC Pulm Med       Date:  2008-10-01       Impact factor: 3.317

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.