Literature DB >> 11860966

The measurement of corneal epithelial thickness in response to hypoxia using optical coherence tomography.

Jianhua Wang1, Desmond Fonn, Trefford L Simpson, Lyndon Jones.   

Abstract

PURPOSE: To determine if corneal epithelial thickness increases in association with corneal edema induced by wearing soft contact lenses during eye closure.
DESIGN: Experimental study.
METHODS: One eye (randomly selected) of twenty noncontact lens wearers (10 males and 10 females, age 35.6 +/- 9.6 years) was patched during 3 hours of soft contact lens (SCL) wear and the contralateral eye acted as a control. Corneal and epithelial thickness of both eyes was measured before and after SCL wear using optical coherence tomography (OCT).
RESULTS: Immediately after contact lens removal, total corneal thickness was increased significantly by 13.8 +/- 2.3% (mean +/- SD) compared with baseline (P <.0001, paired t test) and after 100 minutes was still 4.5 +/- 2.3% thicker than baseline (P <.0001, paired t test). The control eyes showed no change in total corneal thickness (P >.05, paired t test). Immediately after contact lens removal, corneal epithelial thickness was increased by 1.7 +/- 4.8%, but this change was not statistically significant (P >.05, paired t test). Following contact lens removal, epithelial thickness changed significantly (Repeated measure analysis of variance [Re-ANOVA]: F((7,133)) = 4.91, p(H-F) < 0.001) over the next 100 minutes with thinning recorded at 60, 80, and 100 minutes (P <.05, paired t test). There was no significant change over time in epithelial thickness of the control eyes (Re-ANOVA: F(4, 76) = 0.91, p(H-F) = 0.464).
CONCLUSION: OCT demonstrated that corneal epithelial thickness does not increase in response to hypoxia from SCL wear and eye closure, in contrast to a significant increase in total corneal thickness.

Entities:  

Mesh:

Year:  2002        PMID: 11860966     DOI: 10.1016/s0002-9394(01)01382-4

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  18 in total

1.  Repeated measurements of dynamic tear distribution on the ocular surface after instillation of artificial tears.

Authors:  Jianhua Wang; James Aquavella; Jayachandra Palakuru; Suk Chung
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-08       Impact factor: 4.799

2.  Ultrahigh-resolution measurement by optical coherence tomography of dynamic tear film changes on contact lenses.

Authors:  Qi Chen; Jianhua Wang; Aizhu Tao; Meixiao Shen; Shuliang Jiao; Fan Lu
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-11-20       Impact factor: 4.799

3.  Topographic thickness of Bowman's layer determined by ultra-high resolution spectral domain-optical coherence tomography.

Authors:  Aizhu Tao; Jianhua Wang; Qi Chen; Meixiao Shen; Fan Lu; Sander R Dubovy; Mohamed Abou Shousha
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-06-01       Impact factor: 4.799

4.  First demonstration of ocular refractive change using blue-IRIS in live cats.

Authors:  Daniel E Savage; Daniel R Brooks; Margaret DeMagistris; Lisen Xu; Scott MacRae; Jonathan D Ellis; Wayne H Knox; Krystel R Huxlin
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-07-01       Impact factor: 4.799

5.  Assessment of corneal epithelial thickness in dry eye patients.

Authors:  Xinhan Cui; Jiaxu Hong; Fei Wang; Sophie X Deng; Yujing Yang; Xiaoyu Zhu; Dan Wu; Yujin Zhao; Jianjiang Xu
Journal:  Optom Vis Sci       Date:  2014-12       Impact factor: 1.973

6.  Association between corneal biomechanical properties and myopia in Chinese subjects.

Authors:  Z Jiang; M Shen; G Mao; D Chen; J Wang; J Qu; F Lu
Journal:  Eye (Lond)       Date:  2011-05-06       Impact factor: 3.775

7.  Corneal epithelial thickness mapping by Fourier-domain optical coherence tomography in normal and keratoconic eyes.

Authors:  Yan Li; Ou Tan; Robert Brass; Jack L Weiss; David Huang
Journal:  Ophthalmology       Date:  2012-08-20       Impact factor: 12.079

8.  [Corneal changes after wearing orthokeratology contact lenses: an investigation using in vivo, confocal laser scanning microscopy].

Authors:  S Knappe; O Stachs; R Guthoff
Journal:  Ophthalmologe       Date:  2007-08       Impact factor: 1.059

9.  Evaluation of rigid gas permeable lens fitting in keratoconic patients with optical coherence tomography.

Authors:  Amal M Elbendary; Waleed Abou Samra
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-02-08       Impact factor: 3.117

10.  Correlation between epithelial thickness in normal corneas, untreated ectatic corneas, and ectatic corneas previously treated with CXL; is overall epithelial thickness a very early ectasia prognostic factor?

Authors:  Anastasios John Kanellopoulos; Ioannis M Aslanides; George Asimellis
Journal:  Clin Ophthalmol       Date:  2012-05-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.