Biomechanical comparison of the sandblasted and acid-etched and the machined and acid-etched titanium surface for dental implants.

Dehua Li1, Stephen J Ferguson, Thomas Beutler, David L Cochran, Caroline Sittig, Hans Peter Hirt, Daniel Buser.   

Abstract

To make a direct biomechanical comparison between the sandblasted and acid-etched surface (SLA) and the machined and acid-etched surface (MA), a well-established animal model for implant removal torque testing was employed, using a split-mouth experimental design. All implants had an identical cylindrical solid-screw shape with the standard ITI thread configuration, without any macroscopic retentive structures. After 4, 8, and 12 weeks of bone healing, removal torque testing was performed to evaluate the interfacial shear strength of each surface type. Results showed that the SLA surface was more powerful in enhancing the interfacial shear strength of implants in comparison with the MA surface. Removal torque values of the SLA-surfaced implants were about 30% higher than those of the MA-surfaced implants (p = 0.002) except at 4 weeks, when the difference was at the threshold of statistical significance (p = 0.0519). The mean removal torque values for the SLA implants were 1.5074 Nm at 4 weeks, 1.8022 Nm at 8 weeks, and 1.7130 Nm at 12 weeks; and correspondingly, 1.1924 Nm, 1.3092 Nm, and 1.3226 Nm for the MA implants. It can be concluded that the SLA surface achieves a better bone anchorage than the MA surface, and that sandblasting before acid etching has a beneficial effect on the interfacial shear strength. As regards the bone-implant interfacial stiffness calculated from the torque-rotation curve, the SLA implants showed an overall more than 5% higher stiffness compared with the MA implants, although the difference did not reach the statistical significance level. Copyright 2002 John Wiley & Sons, Inc. J Biomed Mater Res 60: 325-332, 2002; DOI 10.1002/jbm.10063

Mesh:

Substances:

Year:  2002        PMID: 11857440     DOI: 10.1002/jbm.10063

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  25 in total

Review 1.  Surface treatments and roughness properties of Ti-based biomaterials.

Authors:  Andrea Bagno; Carlo Di Bello
Journal:  J Mater Sci Mater Med       Date:  2004-09       Impact factor: 3.896

2.  Bone tissue reactions to biomimetic ion-substituted apatite surfaces on titanium implants.

Authors:  Ahmed M Ballo; Wei Xia; Anders Palmquist; Carl Lindahl; Lena Emanuelsson; Jukka Lausmaa; Håkan Engqvist; Peter Thomsen
Journal:  J R Soc Interface       Date:  2012-01-25       Impact factor: 4.118

3.  In vitro bioactivity of sol-gel-derived hydroxyapatite particulate nanofiber modified titanium.

Authors:  Madhab Prasad Bajgai; Daman Chandra Parajuli; Soo-Jin Park; Kong Hee Chu; Hyung-Sub Kang; Hak Yong Kim
Journal:  J Mater Sci Mater Med       Date:  2009-10-23       Impact factor: 3.896

4.  The dependence of MG63 osteoblast responses to (meth)acrylate-based networks on chemical structure and stiffness.

Authors:  Kathryn E Smith; Sharon L Hyzy; Moonhae Sunwoo; Ken A Gall; Zvi Schwartz; Barbara D Boyan
Journal:  Biomaterials       Date:  2010-05-26       Impact factor: 12.479

Review 5.  Silicon micro- and nanofabrication for medicine.

Authors:  Daniel Fine; Alessandro Grattoni; Randy Goodall; Shyam S Bansal; Ciro Chiappini; Sharath Hosali; Anne L van de Ven; Srimeenkashi Srinivasan; Xuewu Liu; Biana Godin; Louis Brousseau; Iman K Yazdi; Joseph Fernandez-Moure; Ennio Tasciotti; Hung-Jen Wu; Ye Hu; Steve Klemm; Mauro Ferrari
Journal:  Adv Healthc Mater       Date:  2013-04-15       Impact factor: 9.933

6.  Tensile force testing of optimized coin-shaped titanium implant attachment kinetics in the rabbit tibiae.

Authors:  Hans Jacob Rønold; Jan Eirik Ellingsen; Ståle Petter Lyngstadaas
Journal:  J Mater Sci Mater Med       Date:  2003-10       Impact factor: 3.896

7.  Integrin alpha2beta1 plays a critical role in osteoblast response to micron-scale surface structure and surface energy of titanium substrates.

Authors:  R Olivares-Navarrete; P Raz; G Zhao; J Chen; M Wieland; D L Cochran; R A Chaudhri; A Ornoy; B D Boyan; Z Schwartz
Journal:  Proc Natl Acad Sci U S A       Date:  2008-10-08       Impact factor: 11.205

8.  Effect of surface anodization on stability of orthodontic microimplant.

Authors:  Sanket Karmarker; Wonjae Yu; Hee-Moon Kyung
Journal:  Korean J Orthod       Date:  2012-02-27       Impact factor: 1.372

9.  TREATMENT OUTCOME OF SHORT DENTAL IMPLANTS.

Authors:  Y O Ajayi; N Nwachukwu; B O Akinboboye
Journal:  J West Afr Coll Surg       Date:  2017 Oct-Dec

10.  Surface characteristics and osteoblastic cell response of alkali-and heat-treated titanium-8tantalum-3niobium alloy.

Authors:  Bo-Ah Lee; Choong-Hee Kang; Mong-Sook Vang; Young-Suk Jung; Xing Hui Piao; Ok-Su Kim; Hyun-Ju Chung; Young-Joon Kim
Journal:  J Periodontal Implant Sci       Date:  2012-12-31       Impact factor: 2.614