Literature DB >> 11809050

The optimal fixation of the cementless acetabular component in primary total hip arthroplasty.

Richard Illgen1, Harry E Rubash.   

Abstract

The optimal fixation of the acetabular component in primary total hip arthroplasty remains controversial. Long-term follow-up studies show that significant loosening rates occur with cemented acetabular components and that these problems persist despite attempts to improve cementing technique. Cementless acetabular components that rely on biologic fixation can have lower rates of radiographic loosening at 10 years compared with cemented acetabular components. Although revision rates for both modes of fixation are largely equivalent at 10 years, the superior radiographic performance of cementless acetabular components at 10 years suggests that biologic fixation through bone ingrowth may provide more durable long-term implant survival compared with cemented fixation. Osteolysis is the major obstacle to long-term cementless acetabular component survival. Potential future options that may inhibit osteolysis include decreasing bone resorption that results from debris-stimulated foreign body response through the use of medications; decreasing the number of particles generated by using alternative bearing surfaces; and improving bone ingrowth, particularly through the use of growth factors and improved implant materials and designs.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11809050     DOI: 10.5435/00124635-200201000-00007

Source DB:  PubMed          Journal:  J Am Acad Orthop Surg        ISSN: 1067-151X            Impact factor:   3.020


  10 in total

1.  Osseointegration of polyethylene implants coated with titanium and biomimetically or electrochemically deposited hydroxyapatite in a rabbit model.

Authors:  Caroline Scemama; Bertrand David; Morad Bensidhoum; Moussa Hamadouche
Journal:  Int Orthop       Date:  2014-05-24       Impact factor: 3.075

Review 2.  Surgical treatment options in patients with impaired bone quality.

Authors:  Norman A Johanson; Jody Litrenta; Jay M Zampini; Frederic Kleinbart; Haviva M Goldman
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

3.  Limitations of conventional radiographs in the assessment of acetabular defects following total hip arthroplasty.

Authors:  Oleg Safir; Cliff Lin; Yona Kosashvili; Ian P Mayne; Allan E Gross; David Backstein
Journal:  Can J Surg       Date:  2012-12       Impact factor: 2.089

4.  No differences in outcomes between cemented and uncemented acetabular components after 12-14 years: results from a randomized controlled trial comparing Duraloc with Charnley cups.

Authors:  Kristian Bjørgul; Wendy M Novicoff; S T Andersen; K Brevig; F Thu; M Wiig; O Ahlund
Journal:  J Orthop Traumatol       Date:  2010-03-03

5.  Ex Vivo Evaluation of Cementless Acetabular Cup Stability Using Impact Analyses with a Hammer Instrumented with Strain Sensors.

Authors:  Antoine Tijou; Giuseppe Rosi; Philippe Hernigou; Charles-Henri Flouzat-Lachaniette; Guillaume Haïat
Journal:  Sensors (Basel)       Date:  2017-12-27       Impact factor: 3.576

6.  A new 3D printing porous trabecular titanium metal acetabular cup for primary total hip arthroplasty: a minimum 2-year follow-up of 92 consecutive patients.

Authors:  Xiao Geng; Yang Li; Feng Li; Xinguang Wang; Ke Zhang; Zhongjun Liu; Hua Tian
Journal:  J Orthop Surg Res       Date:  2020-09-04       Impact factor: 2.359

7.  Experimental and analytical validation of a modular acetabular prosthesis in total hip arthroplasty.

Authors:  Francisco Romero; Farid Amirouche; Luke Aram; Mark H Gonzalez
Journal:  J Orthop Surg Res       Date:  2007-05-16       Impact factor: 2.359

8.  Increased migration of uncemented acetabular cups in female total hip arthroplasty patients with low systemic bone mineral density. A 2-year RSA and 8-year radiographic follow-up study of 34 patients.

Authors:  Sami Finnilä; Niko Moritz; Erkki SvedströM; Jessica J Alm; Hannu T Aro
Journal:  Acta Orthop       Date:  2015-11-16       Impact factor: 3.717

Review 9.  Primary total hip arthroplasty: Staying out of trouble intraoperatively.

Authors:  Shahryar Noordin; Riaz Lakdawala; Bassam A Masri
Journal:  Ann Med Surg (Lond)       Date:  2018-04-04

10.  Evaluation of the bone morphology around four types of porous metal implants placed in distal femur of ovariectomized rats.

Authors:  Stanislav Bondarenko; Nataliya Ashukina; Valentyna Maltseva; Gennadiy Ivanov; Ahmed Amine Badnaoui; Ran Schwarzkopf
Journal:  J Orthop Surg Res       Date:  2020-08-03       Impact factor: 2.359

  10 in total