Literature DB >> 11800120

Hydrophone spatial averaging corrections from 1 to 40 MHz.

E G Radulescu1, P A Lewin, A Goldstein, A Nowicki.   

Abstract

The purpose of this study was to develop and experimentally verify a practical spatial averaging model for frequencies up to 40 MHz. The model is applicable to focused sources of circular geometry, accounts for the effects of hydrophone probe finite aperture, and allows calibration by substitution to be performed when the active elements of reference and tested hydrophone probes differ significantly. Several broadband sources with focal numbers between 3 and 20 were used to produce ultrasound fields with frequencies up to 40 MHz. The effective diameters of the ultrasonic hydrophone probes calibrated in the focal plane of the sources ranged from 150 to 500 microm. Prior to application of the spatial averaging corrections, the hydrophones with diameters smaller than that of the reference hydrophone exhibited experimentally determined absolute sensitivities higher than the true ones. This discrepancy increased with decreasing focal numbers and increasing frequency. It was determined that the error was governed by the cross-section of the beam in the focal plane and the ratio of the effective diameters of the reference and tested hydrophone probes. In addition, the error was found to be reliant on the frequency-dependent effective hydrophone radius. After applying the spatial averaging correction, the overall uncertainty in the hydrophone calibration was on the order of +/-1 dB. The model developed is being extended to be applicable to frequencies beyond 40 MHz, which are becoming increasingly important in diagnostic ultrasound imaging applications.

Mesh:

Year:  2001        PMID: 11800120     DOI: 10.1109/58.971709

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  18 in total

1.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part I: Spatiotemporal Transfer Function and Graphical Guide.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

2.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part II: Experimental Validation of Spatial Averaging Model.

Authors:  Keith A Wear; Yunbo Liu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

3.  A feasibility study of in vivo applications of single beam acoustic tweezers.

Authors:  Ying Li; Changyang Lee; Ruimin Chen; Qifa Zhou; K Kirk Shung
Journal:  Appl Phys Lett       Date:  2014-10-28       Impact factor: 3.791

4.  Directivity and Frequency-Dependent Effective Sensitive Element Size of Membrane Hydrophones: Theory Versus Experiment.

Authors:  Keith A Wear; Christian Baker; Piero Miloro
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-07-24       Impact factor: 2.725

5.  Correction for Hydrophone Spatial Averaging Artifacts for Circular Sources.

Authors:  Keith A Wear; Anant Shah; Christian Baker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-11-24       Impact factor: 2.725

6.  Impact of High-Intensity Ultrasound on Strength of Surgical Mesh When Treating Biofilm Infections.

Authors:  Timothy A Bigelow; Clayton L Thomas; Huaiqing Wu; Kamal M F Itani
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-11-14       Impact factor: 2.725

7.  Scan Parameter Optimization for Histotripsy Treatment of S. Aureus Biofilms on Surgical Mesh.

Authors:  Timothy A Bigelow; Clayton L Thomas; Huaiqing Wu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-10-18       Impact factor: 2.725

8.  Hydrophone Spatial Averaging Correction for Acoustic Exposure Measurements From Arrays-Part II: Validation for ARFI and Pulsed Doppler Waveforms.

Authors:  Keith A Wear; Anant Shah; Aoife M Ivory; Christian Baker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

9.  Hydrophone Spatial Averaging Correction for Acoustic Exposure Measurements From Arrays-Part I: Theory and Impact on Diagnostic Safety Indexes.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

10.  Development of calibration techniques for ultrasonic hydrophone probes in the frequency range from 1 to 100 MHz.

Authors:  S Umchid; R Gopinath; K Srinivasan; P A Lewin; A S Daryoush; L Bansal; M El-Sherif
Journal:  Ultrasonics       Date:  2008-10-21       Impact factor: 2.890

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.