Dosimetric characteristics of the bests double-wall 103Pd brachytherapy source.

A S Meigooni1, Z Bharucha, M Yoe-Sein, K Sowards.   

Abstract

103Pd and 125I brachytherapy sources are being used for interstitial implants in tumor sites such as the prostate. Recently, a double-wall 103Pd source has been introduced, which has a design different from that of sources presently on the market. Dosimetric characteristics (dose rate constant, radial dose function, and anisotropy function) of this source were experimentally and theoretically determined following the AAPM Task Group 43 recommendations and were related to the October 10, 2000 revision of the NIST 1999 SK Standard for 103Pd. Measurements were performed in a Solid Water phantom using LiF thermoluminescent dosimeters. For these measurements, slabs of Solid Water phantom material were machined to accommodate the source and LiF TLD chips of dimensions (3.1 x 3.1 x 0.8 mm3) and (1.0 x 1.0 x 1.0 mm3). The TLD chips were surrounded by at least 10 cm of Solid Water phantom material to provide full scattering conditions. The Monte Carlo simulations were performed in Solid Water and liquid water using the PTRAN code. The results of this investigation show an excellent agreement (within 5%) between the measured (0.67+/-8% cGy h(-1) U(-1)) and calculated (to be 0.65+/-3% cGy h(-1) U(-1)) dose rate constant in Solid Water. The Monte Carlo calculated dose rate constant of the Best 103Pd in water was found to be 0.67+/-0.02 cGy h(-1) U(-1). The radial dose function, g(r), of the new 103Pd source was measured at distances ranging from 0.5 and 7 cm using LiF TLD in Solid Water phantom material. Moreover, the radial dose function of the new source was calculated in liquid water and Solid Water at distances ranging from 0.1 to 7 cm using the PTRAN Monte Carlo Code. The anisotropy function, F(r, theta), of the new 103Pd source was also measured in Solid Water and calculated in both Solid Water and water phantom material. From the anisotropy functions, the anisotropy factors, and anisotropy constant were calculated for each medium. The results indicated that the measured anisotropy constant of the Best 103Pd source in Solid Water was 0.89+/-5%. Complete dosimetric data are described in this manuscript.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11797962     DOI: 10.1118/1.1414007

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Clinical application and validation of an iterative forward projection matching algorithm for permanent brachytherapy seed localization from conebeam-CT x-ray projections.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

2.  Thermoluminescent and Monte Carlo dosimetry of IR06-103Pd brachytherapy source.

Authors:  Pooneh Saidi; Mahdi Sadeghi; S Hamed Hosseini; Claudio Tenreiro
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

3.  Perturbation of TG-43 parameters of the brachytherapy sources under insufficient scattering materials.

Authors:  Mehdi Zehtabian; Sedigheh Sina; Reza Faghihi; Ali Meigooni
Journal:  J Appl Clin Med Phys       Date:  2013-05-06       Impact factor: 2.102

4.  Determination of dosimetric parameters for shielded 153Gd source in prostate cancer brachytherapy.

Authors:  Mahdi Ghorbani; Benyamin Khajetash; Najmeh Ghatei; Mohammad Mehrpouyan; Ali S Meigooni; Ramin Shahraini
Journal:  Radiol Oncol       Date:  2017-02-22       Impact factor: 2.991

5.  Monte Carlo dosimetric characterization of the IsoAid ADVANTAGE 103Pd brachytherapy source.

Authors:  Keith T Sowards
Journal:  J Appl Clin Med Phys       Date:  2007-03-20       Impact factor: 2.102

6.  Cylindrical coordinate based TG-43U1 parameters for dose calculation around elongated brachytherapy sources.

Authors:  Shahid B Awan; Sharifeh A Dini; Manzoor Hussain; David Soleimani-Meigooni; Ali S Meigooni
Journal:  J Appl Clin Med Phys       Date:  2008-04-16       Impact factor: 2.102

7.  Comparison of TG-43 dosimetric parameters of brachytherapy sources obtained by three different versions of MCNP codes.

Authors:  Neda Zaker; Mehdi Zehtabian; Sedigheh Sina; Craig Koontz; Ali S Meigooni
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

8.  Monte Carlo calculations and experimental measurements of the TG-43U1-recommended dosimetric parameters of 125I (Model IR-Seed2) brachytherapy source.

Authors:  Sahar Sheikholeslami; Hasan Ali Nedaie; Mahdi Sadeghi; Hosein Pourbeigy; Sohrab Shahzadi; Mehdi Zehtabian; Mohsen Hasani; Ali S Meigooni
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.