Literature DB >> 18479953

Evaluation of oxygen-response times of phthalocyanine-based crystalline paramagnetic spin probes for EPR oximetry.

Deepti S Vikram1, Rizwan Ahmad, Ramasamy P Pandian, Sergey Petryakov, Periannan Kuppusamy.   

Abstract

The goal of the present study was to evaluate the temporal response of particulate-based EPR oximetry probes to changes in partial pressure of oxygen (pO(2)). In order to accurately evaluate the oxygen-response time, we developed a method for rapid modulation of pO(2) in a chamber containing the probe using an oscillator-driven speaker-diaphragm setup. The apparatus was capable of producing sinusoidal changes in pO(2) at frequencies up to 300 Hz or more. The pressure-modulation setup was used to evaluate the temporal response of some of the most commonly used phthalocyanine-based particulate probes. For validation, the time-response of the probes was compared to that of a high sensitivity pressure sensor. The results revealed that some particulate probes could respond to changes in pO(2) with a temporal response of 3.3 ms (300 Hz). The observations were interpreted in the light of their crystalline packing in favor of oxygen diffusion. The results of the present study should enable the selection of probes for oximetry applications requiring high temporal resolution.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18479953      PMCID: PMC2722937          DOI: 10.1016/j.jmr.2008.04.034

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  19 in total

1.  In vivo EPR: when, how and why?

Authors:  Bernard Gallez; Harold M Swartz
Journal:  NMR Biomed       Date:  2004-08       Impact factor: 4.044

2.  Monitoring oxygenation during the growth of a transplanted tumor.

Authors:  Anna Bratasz; Ramasamy P Pandian; Govindasamy Ilangovan; Periannan Kuppusamy
Journal:  Adv Exp Med Biol       Date:  2006       Impact factor: 2.622

Review 3.  Repetitive tissue pO2 measurements by electron paramagnetic resonance oximetry: current status and future potential for experimental and clinical studies.

Authors:  Nadeem Khan; Benjamin B Williams; Huagang Hou; Hongbin Li; Harold M Swartz
Journal:  Antioxid Redox Signal       Date:  2007-08       Impact factor: 8.401

4.  Carbon-centered radicals as oxygen sensors for in vivo electron paramagnetic resonance: screening for an optimal probe among commercially available charcoals.

Authors:  B F Jordan; C Baudelet; B Gallez
Journal:  MAGMA       Date:  1998-12       Impact factor: 2.310

5.  What does EPR oximetry with solid particles measure--and how does this relate to other measures of PO2?

Authors:  H M Swartz; J Dunn; O Grinberg; J O'Hara; T Walczak
Journal:  Adv Exp Med Biol       Date:  1997       Impact factor: 2.622

6.  Effect of nitrogen dioxide on the EPR property of lithium octa-n-butoxy 2,3-naphthalocyanine (LiNc-BuO) microcrystals.

Authors:  Ramasamy P Pandian; Vinh Dang; Periakaruppan T Manoharan; Jay L Zweier; Periannan Kuppusamy
Journal:  J Magn Reson       Date:  2006-05-11       Impact factor: 2.229

7.  Non-invasive measurement of tumor oxygenation using embedded microparticulate EPR spin probe.

Authors:  Govindasamy Ilangovan; Anna Bratasz; Periannan Kuppusamy
Journal:  Adv Exp Med Biol       Date:  2005       Impact factor: 2.622

8.  Mechanism of oxygen-induced EPR line broadening in lithium phthalocyanine microcrystals.

Authors:  Govindasamy Ilangovan; Jay L Zweier; Periannan Kuppusamy
Journal:  J Magn Reson       Date:  2004-09       Impact factor: 2.229

9.  Novel particulate spin probe for targeted determination of oxygen in cells and tissues.

Authors:  Ramasamy P Pandian; Narasimham L Parinandi; Govindasamy Ilangovan; Jay L Zweier; Periannan Kuppusamy
Journal:  Free Radic Biol Med       Date:  2003-11-01       Impact factor: 7.376

10.  Measurement of oxygen consumption in mouse aortic endothelial cells using a microparticulate oximetry probe.

Authors:  Ramasamy P Pandian; Vijay Kumar Kutala; Narasimham L Parinandi; Jay L Zweier; Periannan Kuppusamy
Journal:  Arch Biochem Biophys       Date:  2003-12-01       Impact factor: 4.013

View more
  1 in total

1.  Fabrication and physical evaluation of a polymer-encapsulated paramagnetic probe for biomedical oximetry.

Authors:  Guruguhan Meenakshisundaram; Edward Eteshola; Ramasamy P Pandian; Anna Bratasz; Stephen C Lee; Periannan Kuppusamy
Journal:  Biomed Microdevices       Date:  2009-08       Impact factor: 2.838

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.