Literature DB >> 11792836

High throughput DNA sequencing with a microfabricated 96-lane capillary array electrophoresis bioprocessor.

Brian M Paegel1, Charles A Emrich, Gary J Wedemayer, James R Scherer, Richard A Mathies.   

Abstract

High throughput DNA sequencing has been performed by using a microfabricated 96-channel radial capillary array electrophoresis (microCAE) microchannel plate detected by a 4-color rotary confocal fluorescence scanner. The microchannel plate features a novel injector for uniform sieving matrix loading as well as high resolution, tapered turns that provide an effective separation length of 15.9 cm on a compact 150-mm diameter wafer. Expanded common buffer chambers for the cathode, anode, and waste reservoirs are used to simplify electrode addressing and to counteract buffering capacity depletion arising from the high electrophoretic current. DNA sequencing data from 95 successful lanes out of 96 lanes run in parallel were batch-processed with basefinder, producing an average read length of 430 bp (phred q > or = 20). Phred quality values were found to exceed 40 (0.01% probability of incorrectly calling a base) for over 80% of the read length. The microCAE system demonstrated here produces sequencing data at a rate of 1.7 kbp/min, a 5-fold increase over current commercial capillary array electrophoresis technology. Additionally, this system permits lower reagent volumes and lower sample concentrations, and it presents numerous possibilities for integrated sample preparation and handling. The unique capabilities of microCAE technology should make it the next generation, high performance DNA sequencing platform.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11792836      PMCID: PMC117347          DOI: 10.1073/pnas.012608699

Source DB:  PubMed          Journal:  Proc Natl Acad Sci U S A        ISSN: 0027-8424            Impact factor:   11.205


  22 in total

1.  Turn geometry for minimizing band broadening in microfabricated capillary electrophoresis channels.

Authors:  B M Paegel; L D Hutt; P C Simpson; R A Mathies
Journal:  Anal Chem       Date:  2000-07-15       Impact factor: 6.986

2.  Eight hundred-base sequencing in a microfabricated electrophoretic device.

Authors:  L Koutny; D Schmalzing; O Salas-Solano; S El-Difrawy; A Adourian; S Buonocore; K Abbey; P McEwan; P Matsudaira; D Ehrlich
Journal:  Anal Chem       Date:  2000-07-15       Impact factor: 6.986

3.  Radial capillary array electrophoresis microplate and scanner for high-performance nucleic acid analysis.

Authors:  Y Shi; P C Simpson; J R Scherer; D Wexler; C Skibola; M T Smith; R A Mathies
Journal:  Anal Chem       Date:  1999-12-01       Impact factor: 6.986

4.  Micromachining a miniaturized capillary electrophoresis-based chemical analysis system on a chip.

Authors:  D J Harrison; K Fluri; K Seiler; Z Fan; C S Effenhauser; A Manz
Journal:  Science       Date:  1993-08-13       Impact factor: 47.728

5.  Ultra-high-speed DNA sequencing using capillary electrophoresis chips.

Authors:  A T Woolley; R A Mathies
Journal:  Anal Chem       Date:  1995-10-15       Impact factor: 6.986

6.  A software system for data analysis in automated DNA sequencing.

Authors:  M C Giddings; J Severin; M Westphall; J Wu; L M Smith
Journal:  Genome Res       Date:  1998-06       Impact factor: 9.043

7.  Optimization of high-speed DNA sequencing on microfabricated capillary electrophoresis channels.

Authors:  S Liu; Y Shi; W W Ja; R A Mathies
Journal:  Anal Chem       Date:  1999-02-01       Impact factor: 6.986

8.  Base-calling of automated sequencer traces using phred. II. Error probabilities.

Authors:  B Ewing; P Green
Journal:  Genome Res       Date:  1998-03       Impact factor: 9.043

9.  DNA sequencing using a four-color confocal fluorescence capillary array scanner.

Authors:  I Kheterpal; J R Scherer; S M Clark; A Radhakrishnan; J Ju; C L Ginther; G F Sensabaugh; R A Mathies
Journal:  Electrophoresis       Date:  1996-12       Impact factor: 3.535

10.  DNA sequencing by capillary electrophoresis with replaceable linear polyacrylamide and laser-induced fluorescence detection.

Authors:  M C Ruiz-Martinez; J Berka; A Belenkii; F Foret; A W Miller; B L Karger
Journal:  Anal Chem       Date:  1993-10-15       Impact factor: 6.986

View more
  29 in total

1.  On-line integration of PCR and cycle sequencing in capillaries: from human genomic DNA directly to called bases.

Authors:  Masahiko Hashimoto; Yan He; Edward S Yeung
Journal:  Nucleic Acids Res       Date:  2003-04-15       Impact factor: 16.971

2.  Thermoplastic microfluidic devices and their applications in protein and DNA analysis.

Authors:  Ke Liu; Z Hugh Fan
Journal:  Analyst       Date:  2011-01-28       Impact factor: 4.616

3.  Polymorphism ratio sequencing: a new approach for single nucleotide polymorphism discovery and genotyping.

Authors:  Robert G Blazej; Brian M Paegel; Richard A Mathies
Journal:  Genome Res       Date:  2003-02       Impact factor: 9.043

4.  A 265-base DNA sequencing read by capillary electrophoresis with no separation matrix.

Authors:  Jennifer Coyne Albrecht; Jennifer S Lin; Annelise E Barron
Journal:  Anal Chem       Date:  2010-12-23       Impact factor: 6.986

5.  Development and evaluation of a microdevice for amino acid biomarker detection and analysis on Mars.

Authors:  Alison M Skelley; James R Scherer; Andrew D Aubrey; William H Grover; Robin H C Ivester; Pascale Ehrenfreund; Frank J Grunthaner; Jeffrey L Bada; Richard A Mathies
Journal:  Proc Natl Acad Sci U S A       Date:  2005-01-18       Impact factor: 11.205

6.  Applying rapid genome sequencing technologies to characterize pathogen genomes.

Authors:  Karyn Meltz Steinberg; David T Okou; Michael E Zwick
Journal:  Anal Chem       Date:  2008-02-01       Impact factor: 6.986

7.  96-well polycarbonate-based microfluidic titer plate for high-throughput purification of DNA and RNA.

Authors:  Małgorzata A Witek; Mateusz L Hupert; Daniel S-W Park; Kirby Fears; Michael C Murphy; Steven A Soper
Journal:  Anal Chem       Date:  2008-03-21       Impact factor: 6.986

8.  Polymer systems designed specifically for DNA sequencing by microchip electrophoresis: a comparison with commercially available materials.

Authors:  Christopher P Fredlake; Daniel G Hert; Brian E Root; Annelise E Barron
Journal:  Electrophoresis       Date:  2008-12       Impact factor: 3.535

9.  Hydrophobically modified polyacrylamide block copolymers for fast, high-resolution DNA sequencing in microfluidic chips.

Authors:  Ryan E Forster; Thomas N Chiesl; Christopher P Fredlake; Corin V White; Annelise E Barron
Journal:  Electrophoresis       Date:  2008-12       Impact factor: 3.535

10.  DNA sequencing by microchip electrophoresis using mixtures of high- and low-molar mass poly(N,N-dimethylacrylamide) matrices.

Authors:  Daniel G Hert; Christopher P Fredlake; Annelise E Barron
Journal:  Electrophoresis       Date:  2008-12       Impact factor: 3.535

View more