Literature DB >> 10939363

Turn geometry for minimizing band broadening in microfabricated capillary electrophoresis channels.

B M Paegel1, L D Hutt, P C Simpson, R A Mathies.   

Abstract

Turns in microfabricated capillary electrophoresis channels generally result in degraded separation quality. To circumvent this limitation, channels were constructed with different types of turns to determine the design that minimizes turn-induced band broadening. In particular, tapered turns were created by narrowing the separation channel width before the start of a turn and widening the channel after the turn is complete. The radius of curvature of the turn, the length over which the channel is tapered, and the degree of tapering were explored. The column efficiencies were determined by examining the resolution of the 271/281 base pair doublet in the separation of a phiX174 HaeIII DNA sizing ladder. Tapered turns with the smallest radius of curvature (250 microm), the shortest tapering length between the separation and turn widths (55 microm), and the largest tapering ratio (4:1 separation channel width to turn channel width) produced the highest resolution separations. These results are discussed by comparison to theoretical predictions of the effect of tapers and turns on analyte band dispersion in capillary electrophoresis.

Mesh:

Substances:

Year:  2000        PMID: 10939363     DOI: 10.1021/ac000054r

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  13 in total

1.  High throughput DNA sequencing with a microfabricated 96-lane capillary array electrophoresis bioprocessor.

Authors:  Brian M Paegel; Charles A Emrich; Gary J Wedemayer; James R Scherer; Richard A Mathies
Journal:  Proc Natl Acad Sci U S A       Date:  2002-01-15       Impact factor: 11.205

Review 2.  The use of capillary electrophoresis for DNA polymorphism analysis.

Authors:  Keith R Mitchelson
Journal:  Mol Biotechnol       Date:  2003-05       Impact factor: 2.695

3.  Enhanced Microchip Electrophoresis Separations Combined with Electrochemical Detection Utilizing a Capillary Embedded in Polystyrene.

Authors:  Benjamin T Mehl; R Scott Martin
Journal:  Anal Methods       Date:  2017-12-06       Impact factor: 2.896

4.  Microfabricated bioprocessor for integrated nanoliter-scale Sanger DNA sequencing.

Authors:  Robert G Blazej; Palani Kumaresan; Richard A Mathies
Journal:  Proc Natl Acad Sci U S A       Date:  2006-04-28       Impact factor: 11.205

5.  Parallel separations using capillary electrophoresis on a multilane microchip with multiplexed laser-induced fluorescence detection.

Authors:  Irena Nikcevic; Aigars Piruska; Kenneth R Wehmeyer; Carl J Seliskar; Patrick A Limbach; William R Heineman
Journal:  Electrophoresis       Date:  2010-08       Impact factor: 3.535

6.  Photopatterned materials in bioanalytical microfluidic technology.

Authors:  Augusto M Tentori; Amy E Herr
Journal:  J Micromech Microeng       Date:  2011-05-01       Impact factor: 1.881

7.  Integrated Multi-process Microfluidic Systems for Automating Analysis.

Authors:  Weichun Yang; Adam T Woolley
Journal:  JALA Charlottesv Va       Date:  2010-06-01

8.  3D Printed Microfluidic Devices for Microchip Electrophoresis of Preterm Birth Biomarkers.

Authors:  Michael J Beauchamp; Anna V Nielsen; Hua Gong; Gregory P Nordin; Adam T Woolley
Journal:  Anal Chem       Date:  2019-05-14       Impact factor: 6.986

9.  High electric field strength two-dimensional peptide separations using a microfluidic device.

Authors:  W Hampton Henley; J Michael Ramsey
Journal:  Electrophoresis       Date:  2012-09       Impact factor: 3.535

10.  Integration of serpentine channels for microchip electrophoresis with a palladium decoupler and electrochemical detection.

Authors:  Amanda L Bowen; R Scott Martin
Journal:  Electrophoresis       Date:  2009-10       Impact factor: 3.535

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.