Literature DB >> 11769888

Comparison and reliability of three goniometric methods for measuring forearm supination and pronation.

R L Gajdosik1.   

Abstract

Active supination and pronation range of motion of the right forearm by 10 men and 21 women were measured with a goniometer using three methods. For Method One the moveable arm was aligned with a pencil held in the hand; for Method Two the moveable arm was placed over the anterior and posterior surface of the distal forearm for supination and pronation, respectively; and for Method Three the moveable arm was aligned parallel with a visualized line connecting the distal ulna and radius. Supination range of motion was greatest for Method One, followed by Methods Three and Two, respectively. Pronation range for Method One was less than for the two other methods. Intraclass correlation coefficients ranged from .81 to .97 for three trials within the test session and from .86 to .96 between the test and a 1-hr. retest session for both actions using all three methods. Method One was the most reliable but appeared invalid for measuring supination because of movements of the 4th and 5th metacarpal bones. Methods Two and Three appeared appropriate for clinical application but not interchangeable.

Entities:  

Mesh:

Year:  2001        PMID: 11769888     DOI: 10.2466/pms.2001.93.2.353

Source DB:  PubMed          Journal:  Percept Mot Skills        ISSN: 0031-5125


  4 in total

1.  Reliability and concurrent validity of mobile health technology for patient self-monitoring in physical rehabilitation.

Authors:  Ofra A Pottorf; Daniel J Lee; Paul-Neil Czujko
Journal:  JSES Int       Date:  2022-02-24

2.  Normative values and affecting factors for the elbow range of motion.

Authors:  Elisa L Zwerus; Nienke W Willigenburg; Vanessa A Scholtes; Matthijs P Somford; Denise Eygendaal; Michel Pj van den Bekerom
Journal:  Shoulder Elbow       Date:  2017-09-11

Review 3.  The reliability and validity of goniometric elbow measurements in adults: A systematic review of the literature.

Authors:  Suzanne F van Rijn; Elisa L Zwerus; Koen Lm Koenraadt; Wilco Ch Jacobs; Michel Pj van den Bekerom; Denise Eygendaal
Journal:  Shoulder Elbow       Date:  2018-06-03

4.  Validity and Reliability of Elbow Range of Motion Measurements Using Digital Photographs, Movies, and a Goniometry Smartphone Application.

Authors:  Renée Keijsers; Elisa L Zwerus; Dagmar R M van Lith; Koen L M Koenraadt; Pjotr Goossens; Bertram The; Michel P J van den Bekerom; Denise Eygendaal
Journal:  J Sports Med (Hindawi Publ Corp)       Date:  2018-11-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.