Literature DB >> 11764339

Tapered titanium cementless total hip replacements: a 10- to 13-year followup study.

R B Bourne1, C H Rorabeck, J J Patterson, J Guerin.   

Abstract

The 10- to-13 year performance of 307 Mallory Head cementless tapered total hip replacements in 283 patients was assessed. Eighty-five percent of patients had a diagnosis of osteoarthritis. Fifty-one percent of patients were women. The mean patient age was 64 +/- 10 years. The Hex Loc cementless acetabular component and titanium alloy femoral heads were used in each patient. At final followup, 37 (13%) patients died, 32 (10%) had revision surgery, and two (1%) were lost to followup. No femoral stem was revised for aseptic loosening, but one was revised because of sepsis and one was revised because of a periprosthetic fracture. Wear, osteolysis, and loosening were problems with the Hex Loc cementless acetabular components and 31 (10%) acetabular components required revision because of these mechanisms. The mean Harris hip score at final followup of the remaining patients was 87 +/- 14 points. Three percent of these patients had thigh pain. Radiographic assessment revealed that no femoral stem or acetabular socket was definitely or probably loose. Three-dimensional wear assessment using the Devane technique was 0.35 mm per year. The Mallory Head cementless, tapered femoral component performed well in the patients in the current study, but unfortunately, the clinical results were compromised by the use of a suboptimal cementless acetabular component, the use of polyethylene that was gamma-irradiated in air, and by the use of titanium alloy femoral heads. Future developments obviously will be in the areas of better acetabular component design, alternate polyethylene sterilization methods, and enhancements of the femoral stem in terms of offset choices, neck design, and perhaps ingrowth surface.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11764339

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  16 in total

1.  High incidence of intraoperative calcar fractures with the cementless CLS Spotorno stem.

Authors:  Carla Timmer; Davey M J M Gerhardt; Enrico de Visser; Marinus de Kleuver; Job L C van Susante
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-05-07

2.  Second-generation extensively porous-coated THA stems at minimum 10-year followup.

Authors:  David W Hennessy; John J Callaghan; Steve S Liu
Journal:  Clin Orthop Relat Res       Date:  2009-04-14       Impact factor: 4.176

3.  Survivorship of 2000 tapered titanium porous plasma-sprayed femoral components.

Authors:  Adolph V Lombardi; Keith R Berend; Thomas H Mallory; Michael D Skeels; Joanne B Adams
Journal:  Clin Orthop Relat Res       Date:  2008-10-31       Impact factor: 4.176

4.  Early Post-operative Periprosthetic Femur Fracture in the Presence of a Non-cemented Tapered Wedge Femoral Stem.

Authors:  H John Cooper; José A Rodriguez
Journal:  HSS J       Date:  2010-04-02

5.  What works best, a cemented or cementless primary total hip arthroplasty?: minimum 17-year followup of a randomized controlled trial.

Authors:  Kristoff Corten; Robert B Bourne; Kory D Charron; Keegan Au; Cecil H Rorabeck
Journal:  Clin Orthop Relat Res       Date:  2010-07-13       Impact factor: 4.176

6.  Formation of hydroxyapatite coating using novel chemo-biomimetic method.

Authors:  Jianhui Xie; Ben Li Luan
Journal:  J Mater Sci Mater Med       Date:  2008-05-02       Impact factor: 3.896

7.  A stature-specific concept for uncemented, primary total hip arthroplasty.

Authors:  Georg W Omlor; Hannah Ullrich; Knut Krahmer; Alexander Jung; Günther Aldinger; Peter Aldinger
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

8.  Can a Conical Implant Successfully Address Complex Anatomy in Primary THA? Radiographs and Hip Scores at Early Followup.

Authors:  Quoqiang Zhang; Stuart B Goodman; William J Maloney; James I Huddleston
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

9.  No improvement in long-term wear and revision rates with the second-generation Biomet cup (RingLoc) in young patients: 141 hips followed for median 12 years.

Authors:  Bart Boesenach; Huub J L van der Heide; Rob G H H Nelissen
Journal:  Acta Orthop       Date:  2011-11-09       Impact factor: 3.717

10.  Minimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty.

Authors:  Brad Ellison; Nicholas A Cheney; Keith R Berend; Adolph V Lombardi; Thomas H Mallory
Journal:  J Orthop Surg Res       Date:  2009-12-09       Impact factor: 2.359

View more