Literature DB >> 2679469

Allograft aortic valve implantation: techniques for all types of aortic valve and root pathology.

M F O'Brien1, D C McGiffin, E G Stafford.   

Abstract

The geometry and degree of symmetry of the diseased aortic root and valve dictate the technical method of implantation of the allograft aortic valve. Five methods are available that are suitable for the full range of aortic root disease: the small aortic root with a valve annulus diameter less than 21 mm, the common aortic valve lesions (valve annulus diameter, 21 to 29 mm), the aneurysmal noncoronary sinus, the moderately large annulus (valve annulus diameter greater than 30 mm), and the aneurysmal aortic root and dilated annulus. Implantation methods include the subcoronary technique, miniroot inclusion technique, and aortic root replacement. Technical variations such as valve inversion during implantation, valve rotation, and continuous or interrupted suture methods are important in certain techniques. The allograft aortic valve is a versatile device that can be used in the surgical management of the full range of aortic valve and aortic root pathology.

Entities:  

Mesh:

Year:  1989        PMID: 2679469     DOI: 10.1016/s0003-4975(10)66877-4

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  5 in total

1.  Cryopreserved aortic homograft replacement in 3 patients with noninfectious inflammatory vascular disease.

Authors:  K Sakuma; H Akimoto; H Yokoyama; A Iguchi; K Tabayashi
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2001-11

2.  Resolution of perivalvular hematoma of the Freestyle stentless aortic root bioprosthesis implanted with a subcoronary technique.

Authors:  Y Takami; H Ina
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2001-11

3.  [Aortic root replacement by cryopreserved homograft for prosthetic valve detachment case due to aortitis].

Authors:  T Yamamoto; H Makuuchi; Y Naruse; T Kobayashi; M Goto; K Nonaka
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  1998-06

4.  [Mid-term evaluation of cryopreserved aortic allograft].

Authors:  H Machida; K Eishi; S Nakajima; K Nakano; S Takamoto; T Tsuji
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  1998-02

5.  Surgical techniques for aortic valve xenotransplantation.

Authors:  Jennie H Kwon; Morgan Hill; Brielle Gerry; Steven W Kubalak; Muhammad Mohiuddin; Minoo N Kavarana; T Konrad Rajab
Journal:  J Cardiothorac Surg       Date:  2021-12-28       Impact factor: 1.637

  5 in total