Literature DB >> 11755094

A desktop magnetic resonance imaging system.

Steven M Wright1, David G Brown, Jay R Porter, David C Spence, Emilio Esparza, David C Cole, F Russell Huson.   

Abstract

Modern magnetic resonance imaging (MRI) systems consist of several complex, high cost subsystems. The cost and complexity of these systems often makes them impractical for use as routine laboratory instruments, limiting their use to hospitals and dedicated laboratories. However, advances in the consumer electronics industry have led to the widespread availability of inexpensive radio-frequency integrated circuits with exceptional abilities. We have developed a small, low-cost MR system derived from these new components. When combined with inexpensive desktop magnets, this type of MR scanner has the promise of becoming standard laboratory equipment for both research and education. This paper describes the development of a prototype desktop MR scanner utilizing a 0.21 T permanent magnet with an imaging region of approximately 2 cm diameter. The system uses commercially available components where possible and is programmed in LabVIEW software. Results from 3D data sets of resolution phantoms and fixed, newborn mice demonstrate the capability of this system to obtain useful images from a system constructed for approximately $13,500.

Entities:  

Mesh:

Year:  2002        PMID: 11755094     DOI: 10.1007/bf02678594

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  10 in total

1.  One-dimensional imaging with a palm-size probe.

Authors:  P J Prado; B Blümich; U Schmitz
Journal:  J Magn Reson       Date:  2000-06       Impact factor: 2.229

2.  In vivo MR micro imaging with conventional radiofrequency coils cooled to 77 degrees K.

Authors:  A C Wright; H K Song; F W Wehrli
Journal:  Magn Reson Med       Date:  2000-02       Impact factor: 4.668

3.  Performance of a high-temperature superconducting probe for in vivo microscopy at 2.0 T.

Authors:  J R Miller; S E Hurlston; Q Y Ma; D W Face; D J Kountz; J R MacFall; L W Hedlund; G A Johnson
Journal:  Magn Reson Med       Date:  1999-01       Impact factor: 4.668

4.  A high-temperature superconducting Helmholtz probe for microscopy at 9.4 T.

Authors:  S E Hurlston; W W Brey; S A Suddarth; G A Johnson
Journal:  Magn Reson Med       Date:  1999-05       Impact factor: 4.668

5.  NMR microspectroscopy using 100 microns planar RF coils fabricated on gallium arsenide substrates.

Authors:  T L Peck; R L Magin; J Kruse; M Feng
Journal:  IEEE Trans Biomed Eng       Date:  1994-07       Impact factor: 4.538

6.  Design and analysis of microcoils for NMR microscopy.

Authors:  T L Peck; R L Magin; P C Lauterbur
Journal:  J Magn Reson B       Date:  1995-08

Review 7.  Challenges in small animal noninvasive imaging.

Authors:  R S Balaban; V A Hampshire
Journal:  ILAR J       Date:  2001

8.  A high-temperature superconducting receiver for nuclear magnetic resonance microscopy.

Authors:  R D Black; T A Early; P B Roemer; O M Mueller; A Mogro-Campero; L G Turner; G A Johnson
Journal:  Science       Date:  1993-02-05       Impact factor: 47.728

9.  Novel approaches to low-cost MRI.

Authors:  A Macovski; S Conolly
Journal:  Magn Reson Med       Date:  1993-08       Impact factor: 4.668

10.  Thin film high temperature superconducting RF coils for low field MRI.

Authors:  J G van Heteren; T W James; L C Bourne
Journal:  Magn Reson Med       Date:  1994-09       Impact factor: 4.668

  10 in total
  8 in total

1.  Medusa: a scalable MR console using USB.

Authors:  Pascal P Stang; Steven M Conolly; Juan M Santos; John M Pauly; Greig C Scott
Journal:  IEEE Trans Med Imaging       Date:  2011-09-26       Impact factor: 10.048

2.  Volumetric analysis of mice lungs in a clinical magnetic resonance imaging scanner.

Authors:  Johannes T Heverhagen; Horst K Hahn; Michael Wegmann; Udo Herz; Chastity D Shaffer Whitaker; Volker Matschl; Heiko Alfke
Journal:  MAGMA       Date:  2004-10-05       Impact factor: 2.310

3.  Compensation for unknown acquisition delay caused by digital receiver without external synchronization in NMR and MRI.

Authors:  X Qin; S Jie; L Jianqi; L Gengying
Journal:  MAGMA       Date:  2005-09-09       Impact factor: 2.310

4.  A powerful graphical pulse sequence programming tool for magnetic resonance imaging.

Authors:  Shen Jie; Liu Ying; Li Jianqi; Li Gengying
Journal:  MAGMA       Date:  2005-12-21       Impact factor: 2.310

5.  A digital receiver with fast frequency- and gain-switching capabilities for MRI systems.

Authors:  Ning Ruipeng; Dai Yidong; Yang Guang; Li Gengying
Journal:  MAGMA       Date:  2009-09-23       Impact factor: 2.310

6.  gr-MRI: A software package for magnetic resonance imaging using software defined radios.

Authors:  Christopher J Hasselwander; Zhipeng Cao; William A Grissom
Journal:  J Magn Reson       Date:  2016-07-01       Impact factor: 2.229

7.  Design of a mobile, homogeneous, and efficient electromagnet with a large field of view for neonatal low-field MRI.

Authors:  Steffen Lother; Steven J Schiff; Thomas Neuberger; Peter M Jakob; Florian Fidler
Journal:  MAGMA       Date:  2016-02-09       Impact factor: 2.310

8.  In vivo 3D brain and extremity MRI at 50 mT using a permanent magnet Halbach array.

Authors:  Thomas O'Reilly; Wouter M Teeuwisse; Danny de Gans; Kirsten Koolstra; Andrew G Webb
Journal:  Magn Reson Med       Date:  2020-07-05       Impact factor: 4.668

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.