Literature DB >> 11753039

Experience with ultrasound scissors and blades (UltraCision) in open and laparoscopic liver resection.

Stefan Schmidbauer1, Klaus K Hallfeldt, Günther Sitzmann, Thorsten Kantelhardt, Arnold Trupka.   

Abstract

OBJECTIVE: The authors used new ultrasonically activated scissors and blades in open and laparoscopic liver resections to investigate their capabilities. SUMMARY BACKGROUND DATA: Despite standardized techniques for liver resection, the surgical death rate ranges from 4% to 20%. Dissection of liver parenchyma may cause considerable blood loss. Further complications include liver failure, hematoma, infections, and bile leakage. The surgical technique is an important factor in preventing intraoperative and postoperative complications. Various techniques have been developed for safe and careful dissection of the liver parenchyma. In addition to blunt dissection using the "finger fracture" technique, various ultrasonic dissectors, water jet dissectors, laser systems, and specially prepared suction devices have been used, but none of these techniques can achieve complete hemostasis during dissection.
METHODS: The instrument was used in open and laparoscopic liver resections. It works by means of a longitudinally vibrating blade or scissors in tissue dissection, coagulation, and preparation. Denaturation of protein and coagulation of vessels up to 2 to 3 mm is possible as a result of the vibration. In this prospective study of a consecutively sampled case series of 41 patients, the author sought to gain experience in handling this instrument and in its capabilities, and they also measured the extent of intraoperative and postoperative blood loss.
RESULTS: The UltraCision was used for 64 open liver resections in 39 patients and for 2 laparoscopic liver resections in 2 patients. Blood loss in laparoscopic resections was less than 50 mL; in open resections it averaged 820 mL. Eleven patients (28%) needed blood transfusions. There were no biliary leakages or abscesses. One patient died after postoperative bleeding leading to fatal liver failure after 4 weeks. Handling of the instrument and cutting and coagulation quality were satisfactory.
CONCLUSIONS: The advantages over other resection techniques are limited heat and smoke generation and the lack of current flow through the patient. The handling and coagulation and cutting quality of the UltraCision appeared satisfactory and safe. The new instrument can be recommended for laparoscopic and open resections of the liver.

Entities:  

Mesh:

Year:  2002        PMID: 11753039      PMCID: PMC1422392          DOI: 10.1097/00000658-200201000-00004

Source DB:  PubMed          Journal:  Ann Surg        ISSN: 0003-4932            Impact factor:   12.969


  21 in total

1.  Transanal mucosectomy using an ultrasonically activated scalpel for ulcerative colitis.

Authors:  M Kusunoki; Y Shoji; H Yanagi; T Yamamura
Journal:  Surg Today       Date:  1999       Impact factor: 2.549

2.  [Evaluation of the Ultracision ultrasonic dissector in thyroid surgery. Prospective randomized study].

Authors:  M Meurisse; T Defechereux; S Maweja; C Degauque; M Vandelaer; E Hamoir
Journal:  Ann Chir       Date:  2000-06

3.  [Cutting with a water jet (jet cutting)--an alternative to the ultrasound aspirator?].

Authors:  H G Rau; H Arnold; F W Schildberg
Journal:  Chirurg       Date:  1990-10       Impact factor: 0.955

4.  [The suction knife in liver surgery. Initial clinical experiences with a simple dissection instrument].

Authors:  D K Wilker; J R Izbicki; W T Knoefel; B Eibl-Eibesfeldt; L Schweiberer
Journal:  Chirurg       Date:  1990-10       Impact factor: 0.955

5.  Techniques of liver resection. Comparison of suction knife, ultrasonic dissector, and contact neodymium-YAG laser.

Authors:  T Schröder; P O Hasselgren; K Brackett; S N Joffe
Journal:  Arch Surg       Date:  1987-10

6.  Liver resection. A comparison using the Nd-YAG laser, an ultrasonic surgical aspirator, or blunt dissection.

Authors:  K G Tranberg; P Rigotti; K A Brackett; H S Bjornson; J E Fischer; S N Joffe
Journal:  Am J Surg       Date:  1986-03       Impact factor: 2.565

7.  [Laparoscopic cholecystectomy in Switzerland. Critical retrospective evaluation of the first 3,722 cases. Swiss Professional Society of Laparoscopic and Thoracoscopic Surgery].

Authors:  R Schlumpf; H P Klotz; H Wehrli; U Herzog
Journal:  Chirurg       Date:  1993-04       Impact factor: 0.955

8.  Resection of the liver with a water jet.

Authors:  D N Papachristou; R Barters
Journal:  Br J Surg       Date:  1982-02       Impact factor: 6.939

9.  Experience with the finger fracture technique to achieve intra-hepatic hemostasis in 75 patients with severe injuries of the liver.

Authors:  H L Pachter; F C Spencer; S R Hofstetter; G F Coppa
Journal:  Ann Surg       Date:  1983-06       Impact factor: 12.969

10.  [Hemostasis in the liver, lungs, and spleen using an infra-red contact coagulator].

Authors:  H Welter; J Seifert; G Nath; A Kreitmair; H Eberhardt; J M Gokel
Journal:  Zentralbl Chir       Date:  1980       Impact factor: 0.942

View more
  40 in total

Review 1.  [Value of laparoscopic liver resection].

Authors:  M R Schön
Journal:  Chirurg       Date:  2010-06       Impact factor: 0.955

2.  How should transection of the liver be performed?: a prospective randomized study in 100 consecutive patients: comparing four different transection strategies.

Authors:  Mickael Lesurtel; Markus Selzner; Henrik Petrowsky; Lucas McCormack; Pierre-Alain Clavien
Journal:  Ann Surg       Date:  2005-12       Impact factor: 12.969

3.  Feasibility of navigated resection of liver tumors using multiplanar visualization of intraoperative 3-dimensional ultrasound data.

Authors:  Siegfried Beller; Michael Hünerbein; Sebastian Eulenstein; Thomas Lange; Peter M Schlag
Journal:  Ann Surg       Date:  2007-08       Impact factor: 12.969

4.  Current techniques of liver transection.

Authors:  Ronnie T P Poon
Journal:  HPB (Oxford)       Date:  2007       Impact factor: 3.647

5.  Parenchymal transection with ultrasonic scalpel in liver resection.

Authors:  O Abbasoglu; I Sayek
Journal:  HPB (Oxford)       Date:  2003       Impact factor: 3.647

6.  [Ultrasonic scissors. New vs resterilized instruments].

Authors:  D Gärtner; K Münz; E Hückelheim; U Hesse
Journal:  Chirurg       Date:  2008-02       Impact factor: 0.955

7.  Ultrasonically activated device for parenchymal division during open hepatectomy.

Authors:  G Belli; P Limongelli; A Belli; C Fantini; A D'Agostino; L Cioffi; G Russo
Journal:  HPB (Oxford)       Date:  2008       Impact factor: 3.647

8.  Precise Navigation of the Surgical Plane with Intraoperative Real-time Virtual Sonography and 3D Simulation in Liver Resection.

Authors:  Ang Lv; Ying Li; Hong-Gang Qian; Hui Qiu; Chun-Yi Hao
Journal:  J Gastrointest Surg       Date:  2018-07-23       Impact factor: 3.452

9.  Bleeding and hemostasis in laparoscopic liver surgery.

Authors:  Mohammad Abu Hilal; Tim Underwood; Matthew G Taylor; Khaled Hamdan; Hassan Elberm; Neil W Pearce
Journal:  Surg Endosc       Date:  2009-07-16       Impact factor: 4.584

10.  Hepatic resection using a bipolar vessel sealing device: technical and histological analysis.

Authors:  Fabrizio Romano; Mattia Garancini; Roberto Caprotti; Giorgio Bovo; Matteo Conti; Elisa Perego; Franco Uggeri
Journal:  HPB (Oxford)       Date:  2007       Impact factor: 3.647

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.