The wear pattern in metal-on-metal hip prostheses.

H L Anissian1, A Stark, V Good, H Dahlstrand, I C Clarke.   

Abstract

The accumulated data suggest that there is a strong correlation between polyethylene wear and osteolysis, which ultimately leads to prosthetic loosening. Second-generation metal-on-metal prostheses have been introduced, with an eye toward resolving this wear-induced osteolysis problem. The metal particles and ions are biologically active and can affect the cell homeostasis. Thus, defining the wear pattern and ratio of a given metal-on-metal prosthesis system is desirable. An early high-wear or run-in phase followed by a low-wear phase or steady state has been suggested for metal-on-metal hip prostheses. The aim of this study was to define the wear pattern of metal-on-metal bearings. The prosthesis systems were tested in a joint simulator. An early accelerated wear phase transformed to a slower wear phase after 700,000 cycles. The run-in and steady-state wear rates for combined head and liner averaged 2.22 mm(3)/Mc and 1.0 mm(3)/ million cycles, respectively. The metal-on-metal prosthesis featured a biphasic wear trend with the wear ratio in run in being more than twofold higher than the steady-state phase. Copyright 2001 John Wiley & Sons, Inc.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11745520     DOI: 10.1002/jbm.1068

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  6 in total

1.  Do ion levels in hip resurfacing differ from metal-on-metal THA at midterm?

Authors:  A Moroni; L Savarino; M Hoque; M Cadossi; N Baldini
Journal:  Clin Orthop Relat Res       Date:  2010-06-11       Impact factor: 4.176

2.  Conversion of a failed hip resurfacing arthroplasty to total hip arthroplasty: pearls and pitfalls.

Authors:  Jacob A Haynes; Jeffrey B Stambough; Robert L Barrack; Denis Nam
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

3.  Diagnosis of adverse local tissue reactions following metal-on-metal hip arthroplasty.

Authors:  Brian P Chalmers; Kevin I Perry; Michael J Taunton; Tad M Mabry; Matthew P Abdel
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

4.  Mid-term result of ceramic bearings in total hip arthroplasty.

Authors:  Ismail Remzi Tozun; Vahit Emre Ozden; Goksel Dikmen; Burak Beksac
Journal:  Int Orthop       Date:  2014-06-01       Impact factor: 3.075

5.  Do ion levels in metal-on-metal hip resurfacing differ from those in metal-on-metal THA at long-term followup?

Authors:  Lucia Savarino; Matteo Cadossi; Eugenio Chiarello; Nicola Baldini; Sandro Giannini
Journal:  Clin Orthop Relat Res       Date:  2013-04-10       Impact factor: 4.176

6.  Influence of head size on the development of metallic wear and on the characteristics of carbon layers in metal-on-metal hip joints.

Authors:  Volker Braunstein; Christoph M Sprecher; Markus A Wimmer; Stefan Milz; Georg Taeger
Journal:  Acta Orthop       Date:  2009-06       Impact factor: 3.717

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.