Literature DB >> 11720254

Two methods of lens opacity measurements in glaucomas.

F K Horn1, A G Jünemann, M Korth.   

Abstract

PURPOSE: Determination of lens opacity is important in aging glaucoma patients, because sensory testing may be influenced by increasing lens opacity. Purpose of this study was to measure lens opacity in normals and glaucoma patients using two different techniques, to compare both methods, and to correlate the results with contrast sensitivity testing.
METHODS: 94 glaucomatous eyes, 47 ocular hypertensive eyes, and 79 control eyes were studied using the following devices: opacity lens meter (OLM, objective back scatter method), stray light meter (SLM, subjective forward scatter using flicker light), and temporal contrast sensitivity (full-field flicker test). SLM results were separately analyzed at the lower and upper flicker disappearance. All subjects were younger than 66 years and had no significant cataracts.
RESULTS: In patients and in normal subjects OLM readings and SLM findings elicited at the upper disappearance point are significantly correlated with age and with each other (R >0.45, P<0.001), while SLM at the lower disappearance point shows no such correlation. In normals, but not in patients, SLM at the lower disappearance point is significantly correlated with temporal contrast sensitivity.
CONCLUSIONS: Both devices can be used for quantifying lens opacity in glaucoma. SLM readings with increasing light intensity at the lower disappearance point seems to be more influenced by the individual flicker sensitivity than determination of the upper flicker disappearance. Therefore, using the SLM in glaucoma patients, the threshold measurements based on the upper disappearance of the flicker should be used instead of the suggested mean threshold measurements.

Entities:  

Mesh:

Year:  2001        PMID: 11720254     DOI: 10.1023/a:1012263922188

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  28 in total

1.  The full-field temporal contrast sensitivity test for glaucoma: influence of cataract.

Authors:  A G Jünemann; F K Horn; P Martus; M Korth
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2000-05       Impact factor: 3.117

2.  The lens opacity meter: a method of quantification of lens opacity by measurement of scattering of incident light.

Authors:  J A Lee; H R Taylor
Journal:  Lens Eye Toxic Res       Date:  1990

3.  Influence of lens opacities on visual field indices.

Authors:  C Costagliola; C De Simone; A Giacoia; G Iuliano; V Landolfo
Journal:  Ophthalmologica       Date:  1990       Impact factor: 3.250

4.  Flicker sensitivity in treated ocular hypertension.

Authors:  M E Tytla; G E Trope; J R Buncic
Journal:  Ophthalmology       Date:  1990-01       Impact factor: 12.079

5.  Lens opacity meter: a new instrument to quantify lens opacity.

Authors:  J Flammer; H Bebie
Journal:  Ophthalmologica       Date:  1987       Impact factor: 3.250

6.  Optic disc morphometry in chronic primary open-angle glaucoma. II. Correlation of the intrapapillary morphometric data to visual field indices.

Authors:  J B Jonas; G C Gusek; G O Naumann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1988       Impact factor: 3.117

7.  The effect of lens opacity on the resolution visual field in normal subjects.

Authors:  P H House; M Schulzer; S M Drance; G R Douglas
Journal:  Doc Ophthalmol       Date:  1993       Impact factor: 2.379

8.  Specific deficits of flicker sensitivity in glaucoma and ocular hypertension.

Authors:  C W Tyler
Journal:  Invest Ophthalmol Vis Sci       Date:  1981-02       Impact factor: 4.799

9.  Lens opacity as a predictor of visual field impairment due to cataract.

Authors:  A Crichton; F Mikelberg; G R Douglas; K Wijsman; S M Drance; R Hollands; H Sutton; M Schulzer
Journal:  Can J Ophthalmol       Date:  1990-10       Impact factor: 1.882

10.  The point-spread function of the eye from 0 degrees to 100 degrees and the pattern electroretinogram.

Authors:  T J van den Berg; B Boltjes
Journal:  Doc Ophthalmol       Date:  1987-12       Impact factor: 2.379

View more
  4 in total

1.  Measurement of autofluorescence in the parapapillary atrophic zone in patients with ocular hypertension.

Authors:  Robert Laemmer; Folkert K Horn; Arne Viestenz; Barbara Link; Anselm G Juenemann; Christian Y Mardin
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-08-01       Impact factor: 3.117

2.  Flicker-defined form perimetry in glaucoma patients.

Authors:  Folkert K Horn; Jan Kremers; Christian Y Mardin; Anselm G Jünemann; Werner Adler; Ralf P Tornow
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-12-16       Impact factor: 3.117

3.  Measuring contrast sensitivity in normal subjects with OPTEC 6500: influence of age and glare.

Authors:  Bettina Hohberger; Robert Laemmer; Werner Adler; Anselm G M Juenemann; Folkert K Horn
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2007-08-11       Impact factor: 3.117

4.  Evaluation of a 345 nm Femtosecond Laser for Corneal Surgery with Respect to Intraocular Radiation Hazard.

Authors:  Johannes Menzel-Severing; Corinna Petsch; Theofilos Tourtas; Naresh Polisetti; Jörg Klenke; Katrin Skerl; Christian Wüllner; Christof Donitzky; Friedrich E Kruse; Jan Kremers; Christian M Hammer
Journal:  PLoS One       Date:  2015-09-11       Impact factor: 3.240

  4 in total