Reliability of gas exchange measurements from two different spiroergometry systems.

T Meyer1, T Georg, C Becker, W Kindermann.   

Abstract

Reliability of two different spiroergometric systems was investigated by comparing gas exchange measurements from two consecutive identical bicycle ergometer ramp exercise tests which were conducted after an initial habituation trial. Twenty-three healthy subjects (age: 25+/-5 years; weight: 71+/-10 kg; peak oxygen uptake: 55+/-9 ml x min(-1) x kg(-1)) took part in the study. One apparatus was a portable mixing chamber system (MetaMax I, Cortex, Leipzig, Germany), the other one a stationary spiroergometric device measuring in the breath-by-breath mode (MetaLyzer 3B, Cortex). There were no relevant systematic changes in gas exchange measurements and heart rate from test 1 to test 2. Intra-class reliability coefficients were 0.984 (oxygen uptake = VO2), 0.977 (carbon dioxide output = VCO2), and 0.973 (minute ventilation = VE) for the MetaMax I, and 0.969 (VO2), 0.964 (VCO2), and 0.953 (VE) for the MetaLyzer 3B. Bland-Altman plots revealed a slightly smaller variability of MetaLyzer 3B measurements compared to those of MetaMax I. It is concluded that the spiroergometric devices MetaMax I and MetaLyzer 3B represent reliable instruments for exercise testing in sports medical routine and research. This is important to decide if longitudinal changes in gas exchange measurements represent clinically meaningful differences in performance or merely inconsistencies of the measuring tool.

Entities:  

Mesh:

Year:  2001        PMID: 11719895     DOI: 10.1055/s-2001-18523

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  26 in total

Review 1.  Measurement of human energy expenditure, with particular reference to field studies: an historical perspective.

Authors:  Roy J Shephard; Yukitoshi Aoyagi
Journal:  Eur J Appl Physiol       Date:  2011-12-11       Impact factor: 3.078

2.  Muscle activation and energy-requirements for varying postures in children and adolescents with cerebral palsy.

Authors:  Olaf Verschuren; Mark D Peterson; Svenja Leferink; Johanna Darrah
Journal:  J Pediatr       Date:  2014-08-20       Impact factor: 4.406

3.  Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems.

Authors:  Scott E Crouter; Amanda Antczak; Jonathan R Hudak; Diane M DellaValle; Jere D Haas
Journal:  Eur J Appl Physiol       Date:  2006-08-03       Impact factor: 3.078

4.  Web-enabled feedback control over energy balance promotes an increase in physical activity and a reduction of body weight and disease risk in overweight sedentary adults.

Authors:  Lutz Erwin Kraushaar; Alexander Krämer
Journal:  Prev Sci       Date:  2014-08

5.  Reliability and responsiveness of cardiopulmonary exercise testing in fatigued persons with multiple sclerosis and low to mild disability.

Authors:  Martin Heine; Lizanne Eva van den Akker; Olaf Verschuren; Anne Visser-Meily; Gert Kwakkel
Journal:  PLoS One       Date:  2015-03-19       Impact factor: 3.240

Review 6.  Open-circuit respirometry: a historical review of portable gas analysis systems.

Authors:  Duncan J Macfarlane
Journal:  Eur J Appl Physiol       Date:  2017-10-17       Impact factor: 3.078

Review 7.  Estimating human energy expenditure: a review of techniques with particular reference to doubly labelled water.

Authors:  Philip Ainslie; Thomas Reilly; Klass Westerterp
Journal:  Sports Med       Date:  2003       Impact factor: 11.136

8.  Test-retest reliability and minimum detectable change using the K4b2: oxygen consumption, gait efficiency, and heart rate for healthy adults during submaximal walking.

Authors:  Benjamin J Darter; Kelly M Rodriguez; Jason M Wilken
Journal:  Res Q Exerc Sport       Date:  2013-06       Impact factor: 2.500

9.  Reliability of the VmaxST portable metabolic measurement system.

Authors:  J Blessinger; B Sawyer; C Davis; B A Irving; A Weltman; G Gaesser
Journal:  Int J Sports Med       Date:  2008-07-23       Impact factor: 3.118

10.  Hertfordshire sarcopenia study: design and methods.

Authors:  Harnish P Patel; Holly E Syddall; Helen J Martin; Claire E Stewart; Cyrus Cooper; Avan Aihie Sayer
Journal:  BMC Geriatr       Date:  2010-06-29       Impact factor: 3.921

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.