Literature DB >> 11716397

The kinematic rotating hinge prosthesis for complex knee arthroplasty.

B D Springer1, A D Hanssen, F H Sim, D G Lewallen.   

Abstract

Fifty-eight patients (69 knees) treated with the Kinematic Rotating Hinged knee prosthesis for complex primary and salvage revision total knee arthroplasty were followed up for an average of 75.2 months (range, 24-199 months). The indications for use of the Kinematic Rotating Hinged knee prosthesis included severe bone loss combined with ligamentous instability (30 knees), nonunion of a periprosthetic fracture (10 knees), an acute periprosthetic fracture (nine knees), severe collateral ligamentous instability (five knees), reimplantation for infection (six knees), nonunion of a supracondylar femoral fracture (four knees), congenital dislocation of the knee (three knees), and treatment of a severely comminuted distal femur (two knees). At the time of surgery, the average patient age was 72 years (range, 46-92 years). Preoperatively, knee extension averaged 4.94 degrees (range, 0 degrees-40 degrees) and flexion averaged 81 degrees (range, 15 degrees-125 degrees). At final followup, knee extension averaged 1.25 degrees (range, -5 degrees-25 degrees) and flexion averaged 94.2 degrees (range, 5 degrees-125 degrees). The preoperative Knee Society Knee score averaged 40.3 points (range, 2-93 points) and improved to 77 points (range, 33-99 points) at final followup. Complications were numerous: 23 (32%) patients experienced at least one complication and 12 (17%) patients had two or more complications. Deep periprosthetic infection was the most common complication (14.5%), followed by patellar complications (13%), and prosthetic component breakage (10%). During the period of this study, there were 15,798 primary and 2673 revision total knee arthroplasties done at the authors' institution. The patients receiving a Kinematic Rotating Hinged knee prosthesis represent a highly complex and small subset (0.37%) of the overall population having knee arthroplasty. Although the use of the Kinematic Rotating Hinged knee prosthesis for these limited indications has been useful for the authors, the incidence of complications and the poor outcome of these complications is disconcerting. Hinged total knee arthroplasty should be reserved for the final salvage option of the treatment options available when doing complex primary and salvage revision knee arthroplasties.

Entities:  

Mesh:

Year:  2001        PMID: 11716397     DOI: 10.1097/00003086-200111000-00037

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  29 in total

1.  Guided-motion hinged knee replacement prosthesis: early survival rate and postoperative patient function and satisfaction.

Authors:  David L Perrin; Thomas R Turgeon
Journal:  Can J Surg       Date:  2020-05-01       Impact factor: 2.089

2.  Periprosthetic fractures around the knee: current concepts and advances in management.

Authors:  Michael R Whitehouse; Sanchit Mehendale
Journal:  Curr Rev Musculoskelet Med       Date:  2014-06

3.  Total Knee Arthroplasty in Severe Unstable Knee: Case-Report and Literature Review.

Authors:  Mohammad Naghi Tahmasebi; Gholamreza Ghorbani Amjad; Mohammad Hassan Kaseb; Kaveh Bashti
Journal:  Arch Bone Jt Surg       Date:  2017-01

4.  Good clinical and radiological results of total knee arthroplasty using varus valgus constrained or rotating hinge implants in ligamentous laxity.

Authors:  Eric Röhner; Kathrin Benad; Timo Zippelius; Nadja Kloss; Benjamin Jacob; Julia Kirschberg; Georg Matziolis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-11-20       Impact factor: 4.342

5.  Can Good Infection Control Be Obtained in One-stage Exchange of the Infected TKA to a Rotating Hinge Design? 10-year Results.

Authors:  Akos Zahar; Daniel O Kendoff; Till O Klatte; Thorsten A Gehrke
Journal:  Clin Orthop Relat Res       Date:  2016-01       Impact factor: 4.176

6.  Computer navigation and distal femoral reconstruction in the oncologic patient.

Authors:  Brian T Palumbo; Eric Henderson; Justin Rizer; Douglas G Letson; David Cheong
Journal:  J Orthop       Date:  2017-03-23

7.  Hinged total knee arthroplasty in the presence of ligamentous deficiency.

Authors:  Daniel Hernández-Vaquero; Manuel A Sandoval-García
Journal:  Clin Orthop Relat Res       Date:  2010-05       Impact factor: 4.176

8.  Quality of life and clinical outcome in salvage revision total knee replacement: hinged vs total condylar design.

Authors:  Susanne Fuchs; Christian Sandmann; Georg Gerdemann; Adrian Skwara; Carsten O Tibesku; Friedrich Bottner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-08-21       Impact factor: 4.342

9.  Haptic robot-assisted surgery improves accuracy of wide resection of bone tumors: a pilot study.

Authors:  Fazel Khan; Andrew Pearle; Christopher Lightcap; Patrick J Boland; John H Healey
Journal:  Clin Orthop Relat Res       Date:  2013-03       Impact factor: 4.176

10.  Distal femoral replacement in nontumor cases with severe bone loss and instability.

Authors:  Keith R Berend; Adolph V Lombardi
Journal:  Clin Orthop Relat Res       Date:  2008-06-04       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.