Literature DB >> 11679258

Antibody-based sensors for heavy metal ions.

D A Blake1, R M Jones, R C Blake, A R Pavlov, I A Darwish, H Yu.   

Abstract

Competitive immunoassays for Cd(II), Co(II), Pb(II) and U(VI) were developed using identical reagents in two different assay formats, a competitive microwell format and an immunosensor format with the KinExA 3000. Four different monoclonal antibodies specific for complexes of EDTA-Cd(II), DTPA-Co(II), 2,9-dicarboxyl-1,10-phenanthroline-U(VI), or cyclohexyl-DTPA-Pb(II) were incubated with the appropriate soluble metal-chelate complex. In the microwell assay format, the immobilized version of the metal-chelate complex was present simultaneously in the assay mixture. In the KinExA format, the antibody was allowed to pre-equilibrate with the soluble metal-chelate complex, then the incubation mixture was rapidly passed through a microcolumn containing the immobilized metal-chelate complex. In all four assays, the KinExA format yielded an assay with 10-1000-fold greater sensitivity. The enhanced sensitivity of the KinExA format is most likely due to the differences in the affinity of the monoclonal antibodies for the soluble versus the immobilized metal-chelate complex. The KinExA 3000 instrument and the Cd(II)-specific antibody were used to construct a prototype assay that could correctly assess the concentration of cadmium spiked into a groundwater sample. Mean analytical recovery of added Cd(II) was 114.25+/-11.37%. The precision of the assay was satisfactory; coefficients of variation were 0.81-7.77% and 3.62-14.16% for within run and between run precision, respectively.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11679258     DOI: 10.1016/s0956-5663(01)00223-8

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  8 in total

1.  Engineering an antibody with picomolar affinity to DOTA chelates of multiple radionuclides for pretargeted radioimmunotherapy and imaging.

Authors:  Kelly Davis Orcutt; Adrian L Slusarczyk; Maryelise Cieslewicz; Benjamin Ruiz-Yi; Kumar R Bhushan; John V Frangioni; K Dane Wittrup
Journal:  Nucl Med Biol       Date:  2010-10-27       Impact factor: 2.408

2.  A highly selective lead sensor based on a classic lead DNAzyme.

Authors:  Tian Lan; Kimberly Furuya; Yi Lu
Journal:  Chem Commun (Camb)       Date:  2010-04-20       Impact factor: 6.222

3.  Aptamer-nanoparticle assembly for logic-based detection.

Authors:  Mohammed I Shukoor; Meghan O Altman; Da Han; Abdullah Tahir Bayrac; Ismail Ocsoy; Zhi Zhu; Weihong Tan
Journal:  ACS Appl Mater Interfaces       Date:  2012-06-18       Impact factor: 9.229

4.  Evaluation of a time efficient immunization strategy for anti-PAH antibody development.

Authors:  Xin Li; Stephen L Kaattari; Mary Ann Vogelbein; Michael A Unger
Journal:  J Immunoassay Immunochem       Date:  2016

5.  Immunoassay Methods and their Applications in Pharmaceutical Analysis: Basic Methodology and Recent Advances.

Authors:  Ibrahim A Darwish
Journal:  Int J Biomed Sci       Date:  2006-09

Review 6.  Aptamers and their biological applications.

Authors:  Kyung-Mi Song; Seonghwan Lee; Changill Ban
Journal:  Sensors (Basel)       Date:  2012-01-09       Impact factor: 3.576

7.  Kinetic Exclusion Assay of Biomolecules by Aptamer Capture.

Authors:  Mark H Smith; Daniel Fologea
Journal:  Sensors (Basel)       Date:  2020-06-18       Impact factor: 3.576

Review 8.  Bio-Recognition in Spectroscopy-Based Biosensors for *Heavy Metals-Water and Waterborne Contamination Analysis.

Authors:  Alessandra Aloisi; Antonio Della Torre; Angelantonio De Benedetto; Rosaria Rinaldi
Journal:  Biosensors (Basel)       Date:  2019-07-30
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.