MAPD--an objective way to select mAs for paediatric brain CT.

E T Wong1, S K Yu, M Lai, Y C Wong, P C Lau.   

Abstract

CT is an advanced imaging modality, but the imaging parameters are normally selected subjectively. For standard head examinations, most of the parameters used are consistent amongst different centres, with the exception of large variations in the selection of the tube current-exposure time product (mAs). As a result, CT images may contain unacceptable levels of noise, or the patient may receive excessive radiation. In this study, the maximum anteroposterior diameter (MAPD) was shown to be a good criterion for mAs selection, and could be measured in a pilot view. 200 paediatric brain CT studies were randomly selected to determine the MAPD at the mid brain level. With knowledge of MAPD distribution, a phantom study was performed to determine the relationship between MAPD and the mAs required for consistent and acceptable image noise. It was found that the required mAs increased linearly with MAPD. Assuming the manufacturer's recommended value is "appropriate" for the average MAPD, the appropriate mAs value could be estimated. Using this method, appropriate mAs values were calculated retrospectively for a group of 240 randomly selected paediatric brain CT studies and compared with the actual mAs subjectively determined by the radiographer. Although their average values were similar, the difference between the calculated and actual values deviated markedly in some cases. When the actual mAs was smaller than the calculated value, higher image noise was observed. However, reduction of image noise was barely observed when the applied mAs was larger than the calculated value. Thus, this method is more objective and appropriate for determination of the mAs value for paediatric brain CT than the traditional subjective method.

Entities:  

Mesh:

Year:  2001        PMID: 11675311     DOI: 10.1259/bjr.74.886.740932

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  4 in total

1.  Radiation exposure from CT in early childhood: a French large-scale multicentre study.

Authors:  M-O Bernier; J-L Rehel; H J Brisse; X Wu-Zhou; S Caer-Lorho; S Jacob; J F Chateil; B Aubert; D Laurier
Journal:  Br J Radiol       Date:  2012-01       Impact factor: 3.039

2.  Reducing radiation exposure from computed tomography of the brain in children--report of a practical approach.

Authors:  Sui-To Wong; Gwendolin Yiu; Yiu-Man Poon; Ming-Keung Yuen; Dawson Fong
Journal:  Childs Nerv Syst       Date:  2012-01-12       Impact factor: 1.475

3.  Assessment of image quality of a standard and three dose-reducing protocols in adult cranial CT.

Authors:  Sadi Gündoğdu; Kamran Mahmutyazicioğlu; Hüseyin Ozdemir; Ahmet Savranlar; Kiyasettin Asil
Journal:  Eur Radiol       Date:  2004-12-02       Impact factor: 5.315

4.  Optimised low-dose multidetector CT protocol for children with cranial deformity.

Authors:  Jose Luis Vazquez; Miguel Angel Pombar; Jose Manuel Pumar; Victor Miguel del Campo
Journal:  Eur Radiol       Date:  2013-03-16       Impact factor: 5.315

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.