Literature DB >> 23504037

Optimised low-dose multidetector CT protocol for children with cranial deformity.

Jose Luis Vazquez1, Miguel Angel Pombar, Jose Manuel Pumar, Victor Miguel del Campo.   

Abstract

OBJECTIVE: To present an optimised low-dose multidetector computed tomography (MDCT) protocol for the study of children with cranial deformity.
METHODS: Ninety-one consecutive MDCT studies were performed in 80 children. Studies were performed with either our standard head CT protocol (group 1, n = 20) or a low-dose cranial deformity protocol (groups 2 and 3). Group 2 (n = 38), initial, and group 3 (n = 33), final and more optimised. All studies were performed in the same 64-MDCT equipment. Cranial deformity protocol was gradationally optimised decreasing kVp, limiting mA range, using automatic exposure control (AEC) and increasing the noise index (NI). Image quality was assessed. Dose indicators such us CT dose index volume (CTDIvol), dose-length product (DLP) and effective dose (E) were used.
RESULTS: The optimised low-dose protocol reached the following values: 80 kVp, mA range: 50-150 and NI = 23. We achieved a maximum dose reduction of 10-22 times in the 1- to 12-month-old cranium in regard to the 2004 European guidelines for MDCT.
CONCLUSION: A low-dose MDCT protocol that may be used as the first diagnostic imaging option in clinically selected patients with skull abnormalities. KEY POINTS: • MDCT is a very useful tool in the study of skull lesions • Low-dose MDCT minimises child exposure to ionising radiation while maintaining image quality • Low-dose MDCT should be considered as the first imaging option in selected patients.

Entities:  

Mesh:

Year:  2013        PMID: 23504037     DOI: 10.1007/s00330-013-2806-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  44 in total

Review 1.  American Academy of Pediatrics AAP Task Force on Infant Positioning and SIDS: Positioning and SIDS.

Authors: 
Journal:  Pediatrics       Date:  1992-06       Impact factor: 7.124

2.  A pediatric CT dose and risk estimator.

Authors:  Adam M Alessio; Grace S Phillips
Journal:  Pediatr Radiol       Date:  2010-07-11

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

4.  Radioprotection to the eye during CT scanning.

Authors:  K D Hopper; J D Neuman; S H King; A R Kunselman
Journal:  AJNR Am J Neuroradiol       Date:  2001 Jun-Jul       Impact factor: 3.825

5.  Eye-lens bismuth shielding in paediatric head CT: artefact evaluation and reduction.

Authors:  Maria Raissaki; Kostas Perisinakis; John Damilakis; Nicholas Gourtsoyiannis
Journal:  Pediatr Radiol       Date:  2010-06-16

6.  [Protection of eye lens in computed tomography--dose evaluation on an anthropomorphic phantom using thermo-luminescent dosimeters and Monte-Carlo simulations].

Authors:  B Keil; J Wulff; R Schmitt; D Auvanis; D Danova; J T Heverhagen; M Fiebich; B Madsack; R Leppek; K J Klose; K Zink
Journal:  Rofo       Date:  2008-11-28

7.  Dose reduction in CT using bismuth shielding: measurements and Monte Carlo simulations.

Authors:  Kyung-Hwan Chang; Wonho Lee; Dong-Myung Choo; Choon-Sik Lee; Youhyun Kim
Journal:  Radiat Prot Dosimetry       Date:  2009-12-03       Impact factor: 0.972

8.  Is administration of enteric contrast material safe before abdominal CT in children who require sedation? Experience with chloral hydrate and pentobarbital.

Authors:  Matthew A Ziegler; Bradley L Fricke; Lane F Donnelly
Journal:  AJR Am J Roentgenol       Date:  2003-01       Impact factor: 3.959

9.  Analysis of posterior plagiocephaly: deformational versus synostotic.

Authors:  J B Mulliken; D L Vander Woude; M Hansen; R A LaBrie; R M Scott
Journal:  Plast Reconstr Surg       Date:  1999-02       Impact factor: 4.730

Review 10.  Diagnostic imaging in the management of craniosynostoses.

Authors:  Bibiana Kotrikova; Robert Krempien; Kolja Freier; Joachim Mühling
Journal:  Eur Radiol       Date:  2006-12-07       Impact factor: 7.034

View more
  6 in total

1.  Limiting CT radiation dose in children with craniosynostosis: phantom study using model-based iterative reconstruction.

Authors:  Touko Kaasalainen; Kirsi Palmu; Anniina Lampinen; Vappu Reijonen; Junnu Leikola; Riku Kivisaari; Mika Kortesniemi
Journal:  Pediatr Radiol       Date:  2015-05-05

2.  Evaluation of the impact of organ-specific dose reduction on image quality in pediatric chest computed tomography.

Authors:  Johannes Boos; Patric Kröpil; Dirk Klee; Philipp Heusch; Lars Schimmöller; Jörg Schaper; Gerald Antoch; Rotem S Lanzman
Journal:  Pediatr Radiol       Date:  2014-03-29

3.  Pediatric craniosynostosis computed tomography: an institutional experience in reducing radiation dose while maintaining diagnostic image quality.

Authors:  Izabella L Barreto; Ibrahim S Tuna; Dhanashree A Rajderkar; Jessica A Ching; Lance S Governale
Journal:  Pediatr Radiol       Date:  2021-11-03

4.  A pragmatic approach to determine the optimal kVp in cone beam CT: balancing contrast-to-noise ratio and radiation dose.

Authors:  R Pauwels; O Silkosessak; R Jacobs; R Bogaerts; H Bosmans; S Panmekiate
Journal:  Dentomaxillofac Radiol       Date:  2014-04-08       Impact factor: 2.419

5.  Dedicated sub 0.1 mSv 3DCT using MBIR in children with suspected craniosynostosis: quality assessment.

Authors:  Caroline W Ernst; Tine L Hulstaert; Dries Belsack; Nico Buls; Gert Van Gompel; Koenraad H Nieboer; Ronald Buyl; Filip Verhelle; Michel De Maeseneer; Johan de Mey
Journal:  Eur Radiol       Date:  2015-06-30       Impact factor: 5.315

Review 6.  Craniosynostosis : Updates in Radiologic Diagnosis.

Authors:  Hyun Jeong Kim; Hong Gee Roh; Il Woo Lee
Journal:  J Korean Neurosurg Soc       Date:  2016-05-10
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.