Literature DB >> 11593206

Accuracy and reproducibility of coronary flow rate assessment by real-time contrast echocardiography: in vitro and in vivo studies.

S Lafitte1, H Masugata, B Peters, M Togni, M Strachan, B Yao, O L Kwan, A N DeMaria.   

Abstract

Real-time myocardial contrast echo (MCE) provides the potential to assess myocardial blood flow from time-intensity refilling curves after high-energy bubble destruction. This study validated the accuracy of this approach and the effect of specific examination variables and instrument settings on results. The effects of examination depth and angle as well as dynamic range, pulse repetition frequency, and line density were assessed with the use of in vitro incremental flow rates produced in an in vitro tissue phantom. In vivo recordings of real-time imaging with an infusion of a contrast agent (Optison) were obtained in 7 open-chest dogs with graded left anterior descending artery stenosis at baseline and during adenosine hyperemia, and were compared with flow probe measurements. After bubble destruction, time-intensity data were fitted to an exponential function, and the rate of intensity increase (b) and peak plateau intensity (A) were derived from refilling curves. In vivo real-time values for b, but not A, correlated closely with flow probe measures (r = 0.93). A similar correlation for b was observed in vitro (r = 0.98). The correlation between flow rate and b was influenced by several examination variables, including depth, angle, and instrument settings. Real-time MCE provides accurate quantification of coronary flow by assessing the rate of microbubble refilling. However, this parameter may be affected by several examination and instrument variables. Therefore, real-time MCE refilling measures are best applied by comparing baseline values with those of stress studies.

Entities:  

Mesh:

Year:  2001        PMID: 11593206     DOI: 10.1067/mje.2001.112908

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  6 in total

1.  Blood perfusion of the contralateral testis evaluated with contrast-enhanced ultrasound in rabbits with unilateral testicular torsion.

Authors:  Lin Chen; Wei-Wei Zhan; Zhou-Jun Shen; Wen-Bin Rui; Chen Lv; Man Chen; Jian-Qiao Zhou; Ping Zhou; Mi Zhou; Ying Zhu
Journal:  Asian J Androl       Date:  2009-01-19       Impact factor: 3.285

2.  Fourier phase analysis can be used to objectively analyze real-time myocardial contrast echocardiograms.

Authors:  Alexander Hansen; Raffi Bekeredjian; Grigorious Korosoglou; David Wolf; Arthur Filusch; Helmut F Kuecherer
Journal:  Int J Cardiovasc Imaging       Date:  2004-08       Impact factor: 2.357

Review 3.  Echocardiography in translational research: of mice and men.

Authors:  Marielle Scherrer-Crosbie; Helène B Thibault
Journal:  J Am Soc Echocardiogr       Date:  2008-08-23       Impact factor: 5.251

4.  Acute hyperglycemia reduces myocardial blood flow reserve and the magnitude of reduction is associated with insulin resistance: a study in nondiabetic humans using contrast echocardiography.

Authors:  Sahar S Abdelmoneim; Mary E Hagen; Edward Mendrick; Vishwanath Pattan; Benjamin Wong; Barbara Norby; Tamara Roberson; Troy Szydel; Rita Basu; Ananda Basu; Sharon L Mulvagh
Journal:  Heart Vessels       Date:  2012-11-23       Impact factor: 2.037

5.  Quantification of resting myocardial blood flow velocity in normal humans using real-time contrast echocardiography. A feasibility study.

Authors:  Siri Malm; Sigmund Frigstad; Frode Helland; Kjetil Oye; Stig Slordahl; Terje Skjarpe
Journal:  Cardiovasc Ultrasound       Date:  2005-06-16       Impact factor: 2.062

6.  The value of real-time myocardial contrast echocardiography for detecting coronary microcirculation function in coronary artery disease patients.

Authors:  Lulu Sun; Zilong Wang; Tongda Xu; Defeng Pan; Li Liang; Ji Hao; Xiaoping Wang; Dongye Li
Journal:  Anatol J Cardiol       Date:  2018-01       Impact factor: 1.596

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.