Literature DB >> 15529903

Fourier phase analysis can be used to objectively analyze real-time myocardial contrast echocardiograms.

Alexander Hansen1, Raffi Bekeredjian, Grigorious Korosoglou, David Wolf, Arthur Filusch, Helmut F Kuecherer.   

Abstract

BACKGROUND: Real-time myocardial contrast echocardiography (MCE) is increasingly used to assess myocardial perfusion. However, objective methods for evaluating MCE are not yet widely available. We sought to validate the ability of Fourier analysis applied to MCE to assess serial changes in microvascular perfusion during coronary occlusion and reperfusion.
METHODS: Six pigs underwent 45 min of left anterior descending coronary artery (LAD) occlusion followed by 120 min of reperfusion. Real time MCE was performed at baseline, during coronary occlusion, and at 5, 30, 60 and 120 min of reperfusion. Signal intensities from replenishment curves were fitted to an exponential function to obtain plateau SI (A) and the rate of SI rise (b). MCE images were mathematically transformed using a first-harmonic Fourier algorithm displaying the sequence of myocardial intensity changes as phase angles in parametric images. The phase angle difference (PD) of posterior vs. anterior region was calculated as an index of myocardial opacification heterogeneity and compared to MCE index of myocardial blood flow A x b.
RESULTS: After initial hyperemia, a progressive reduction in flow was observed during reperfusion. During LAD occlusion signal intensities were significantly reduced in anterior regions (A x b = 0.02+/-0.01) compared to baseline (1.2+/-0.34, p < 0.01) defining risk areas and approached higher levels postrecanalization (A x b = 1.48+/-0.6) but gradually decreased during 120 min of reperfusion (A = 0.51+/-0.3, p < 0.01). Similarly, profiles of phase angles in LAD perfusion territorities were consistently modified during reperfusion. The mean PD at baseline was 18 degrees+/-15 degrees. PD decreased during coronary occlusion to -108 degrees+/-38 degrees, increased to 29 degrees+/-19 degrees postrecanalization but decreased to -61 degrees+/-35 degrees after 120 min of reperfusion. PD significantly correlated with A (r = 0.8, p < 0.0001) and b (r = 0.73, p < 0.0001).
CONCLUSIONS: The progressive reduction in post-ischemic microvascular perfusion was accurately detected by real-time MCE. Fourier phase imaging is feasible to quantify dynamics of myocardial opacification in a simple and objective format and is a promising approach for the interpretation of contrast echocardiograms.

Entities:  

Mesh:

Year:  2004        PMID: 15529903     DOI: 10.1023/b:caim.0000041931.42557.2b

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  17 in total

1.  Accuracy and reproducibility of coronary flow rate assessment by real-time contrast echocardiography: in vitro and in vivo studies.

Authors:  S Lafitte; H Masugata; B Peters; M Togni; M Strachan; B Yao; O L Kwan; A N DeMaria
Journal:  J Am Soc Echocardiogr       Date:  2001-10       Impact factor: 5.251

2.  Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion.

Authors:  K Wei; A R Jayaweera; S Firoozan; A Linka; D M Skyba; S Kaul
Journal:  Circulation       Date:  1998-02-10       Impact factor: 29.690

3.  Assessment of regional myocardial blood flow with myocardial contrast two-dimensional echocardiography.

Authors:  S Kaul; P Kelly; J D Oliner; W P Glasheen; M W Keller; D D Watson
Journal:  J Am Coll Cardiol       Date:  1989-02       Impact factor: 24.094

4.  Echocardiographic quantification of left ventricular asynergy in coronary artery disease with Fourier phase imaging.

Authors:  A Hansen; C Krueger; S E Hardt; M Haass; H F Kuecherer
Journal:  Int J Cardiovasc Imaging       Date:  2001-04       Impact factor: 2.357

5.  Myocardial reperfusion: a double-edged sword?

Authors:  E Braunwald; R A Kloner
Journal:  J Clin Invest       Date:  1985-11       Impact factor: 14.808

6.  Contrast echocardiography can assess risk area and infarct size during coronary occlusion and reperfusion: experimental validation.

Authors:  Stéphane Lafitte; Aya Higashiyama; Hisashi Masugata; Barry Peters; Monet Strachan; Oi Ling Kwan; Anthony N DeMaria
Journal:  J Am Coll Cardiol       Date:  2002-05-01       Impact factor: 24.094

7.  Ischemia-reperfusion injury at the microvascular level: treatment by endothelin A-selective antagonist and evaluation by myocardial contrast echocardiography.

Authors:  L Galiuto; A N DeMaria; U del Balzo; K May-Newman; S F Flaim; P L Wolf; M Kirchengast; S Iliceto
Journal:  Circulation       Date:  2000-12-19       Impact factor: 29.690

8.  Progressive impairment of regional myocardial perfusion after initial restoration of postischemic blood flow.

Authors:  G Ambrosio; H F Weisman; J A Mannisi; L C Becker
Journal:  Circulation       Date:  1989-12       Impact factor: 29.690

9.  Detection of acute myocardial ischemia during pharmacological stress in graded coronary artery stenosis: analysis of left ventricular asynchrony using Fourier phase imaging in pigs.

Authors:  Alexander Hansen; Stefan E Hardt; Isabel Pekrul; Arthur Filusch; Raffi Bekeredjian; Helmut F Kuecherer
Journal:  Int J Cardiovasc Imaging       Date:  2003-04       Impact factor: 2.357

10.  Echocardiographic Fourier phase and amplitude imaging for quantification of ischemic regional wall asynergy: an experimental study using coronary microembolization in dogs.

Authors:  H F Kuecherer; W Schoels; L D Sterns; K Freigang; G da S Kleber; J Brachmann; W Kuebler
Journal:  J Am Coll Cardiol       Date:  1995-05       Impact factor: 24.094

View more
  1 in total

1.  Usefulness of myocardial parametric imaging to evaluate myocardial viability in experimental and in clinical studies.

Authors:  G Korosoglou; A Hansen; R Bekeredjian; A Filusch; S Hardt; D Wolf; D Schellberg; H A Katus; H Kuecherer
Journal:  Heart       Date:  2005-06-06       Impact factor: 5.994

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.