Literature DB >> 10362037

Assessment of bronchial reactivity by forced oscillation admittance avoids the upper airway artefact.

R Farré1, M Rotger, F Marchal, R Peslin, D Navajas.   

Abstract

The forced oscillation technique (FOT) allows easy assessment of bronchial reactivity. The use of a standard FOT generator (SG) results in changes in respiratory system resistance (delta Rrs,SG) which are affected by an artefact caused by the extrathoracic upper airway (EUA). The aim was to improve the FOT assessment of bronchial reactivity with the SG by computing the change in FOT admittance (delta Ars,SG), which is theoretically unaffected by this artefact. Delta Rrs,SG and delta Ars,SG after bronchial challenge in 17 children were compared with the values measured with a head generator (HG) FOT setup (delta Rrs,HG and delta Ars,HG, respectively), which were taken as a reference, since HG provides data virtually freed from the EUA artefact. At 10 Hz, the SG significantly underestimated the resistance change: delta Rrs,SG=1.77+/-0.62 versus delta Rrs,HG=6.09+/-1.23 hPa x L(-1) x s. Delta Rrs,SG and delta Rrs,HG did not show a significant correlation. By contrast, the amplitude of the change in admittance measured by SG was close to the one obtained with the reference HG: /delta Ars,SG/=29.5+/-4.6 versus /delta Ars,HG/=32.7+/-3.9 mL x hPa(-1) x s(-1). /Delta Ars,SG/ and /delta Ars,HG/ showed a significant correlation (r=0.65, p>0.01). Similar results were found up to 20 Hz. The extrathoracic upper airway artefact was minimized when computing the change in admittance with the standard generator. This forced oscillation technique index may improve the sensitivity in assessing bronchial reactivity with the standard generator setup, which is the most common and easiest to use method for routine lung function testing.

Entities:  

Mesh:

Year:  1999        PMID: 10362037     DOI: 10.1034/j.1399-3003.1999.13d11.x

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  4 in total

Review 1.  Respiratory input impedance measurement: forced oscillation methods.

Authors:  D MacLeod; M Birch
Journal:  Med Biol Eng Comput       Date:  2001-09       Impact factor: 2.602

2.  The site of airway obstruction among patients of emphysema: role of impulse oscillometry.

Authors:  Hs Hira; Jitender Munjal; Sanjay Zachariah; Mr Chauhan; Anshu Singh
Journal:  Lung India       Date:  2008-01

3.  Clinical applications of forced oscillation techniques (FOT) in patients with bronchial asthma.

Authors:  C W Kim; J S Kim; J W Park; C S Hong
Journal:  Korean J Intern Med       Date:  2001-06       Impact factor: 2.884

4.  Influence of cheek support on respiratory impedance measured by forced oscillation technique.

Authors:  Akemi Uchida; Satoru Ito; Béla Suki; Hiroki Matsubara; Yoshinori Hasegawa
Journal:  Springerplus       Date:  2013-07-25
  4 in total