Real-time three-dimensional echocardiography for measurement of left ventricular volumes.

M A Schmidt1, C J Ohazama, K O Agyeman, R Z Freidlin, M Jones, J M Laurienzo, C L Brenneman, A E Arai, O T von Ramm, J A Panza.   

Abstract

Left ventricular (LV) volumes are important prognostic indexes in patients with heart disease. Although several methods can evaluate LV volumes, most have important intrinsic limitations. Real-time 3-dimensional echocardiography (RT3D echo) is a novel technique capable of instantaneous acquisition of volumetric images. The purpose of this study was to validate LV volume calculations with RT3D echo and to determine their usefulness in cardiac patients. To this end, 4 normal subjects and 21 cardiac patients underwent magnetic resonance imaging (MRI) and RT3D echo on the same day. A strong correlation was found between LV volumes calculated with MRI and with RT3D echo (r = 0.91; y = 20.1 + 0.71x; SEE 28 ml). LV volumes obtained with MRI were greater than those obtained with RT3D echo (126 +/- 83 vs 110 +/- 65 ml; p = 0.002), probably due to the fact that heart rate during MRI acquisition was lower than that during RT3D echo examination (62 +/- 11 vs 79 +/- 16 beats/min; p = 0.0001). Analysis of intra- and interobserver variability showed strong indexes of agreement in the measurement of LV volumes with RT3D echo. Thus, LV volume measurements with RT3D echo are accurate and reproducible. This technique expands the use of ultrasound for the noninvasive evaluation of cardiac patients and provides a new tool for the investigational study of cardiovascular disease.

Entities:  

Mesh:

Year:  1999        PMID: 10606118     DOI: 10.1016/s0002-9149(99)00591-3

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  11 in total

Review 1.  Real-time three-dimensional echocardiography: an overview.

Authors:  J A Panza
Journal:  Int J Cardiovasc Imaging       Date:  2001-06       Impact factor: 2.357

Review 2.  Novel techniques for assessment of left ventricular systolic function.

Authors:  Sonal Chandra; Hicham Skali; Ron Blankstein
Journal:  Heart Fail Rev       Date:  2011-07       Impact factor: 4.214

3.  Contrast-enhanced versus non-enhanced three-dimensional echocardiography of left ventricular volumes.

Authors:  J A van der Heide; H F J Mannaerts; L Yang; G T Sieswerda; C A Visser; O Kamp
Journal:  Neth Heart J       Date:  2008-02       Impact factor: 2.380

4.  Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography.

Authors:  Kian Keong Poh; Robert A Levine; Jorge Solis; Liang Shen; Mary Flaherty; Yue-Jian Kang; J Luis Guerrero; Judy Hung
Journal:  Eur Heart J       Date:  2008-02-09       Impact factor: 29.983

5.  Vibrating interventional device detection using real-time 3-D color Doppler.

Authors:  Matthew P Fronheiser; Salim F Idriss; Patrick D Wolf; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008       Impact factor: 2.725

6.  The left ventricle of the ungulate heart: morphofunctional characteristics and muscle fiber orientation.

Authors:  M P Roshchevsky; E V Bartusevich; A S Gulyaeva; I M Roshchevskaya
Journal:  Dokl Biol Sci       Date:  2011-05-12

7.  3D Myocardial Elastography In Vivo.

Authors:  Clement Papadacci; Ethan A Bunting; Elaine Y Wan; Pierre Nauleau; Elisa E Konofagou
Journal:  IEEE Trans Med Imaging       Date:  2016-11-01       Impact factor: 10.048

8.  Real-time 3-D ultrasound guidance of interventional devices.

Authors:  Edward D Light; John F Angle; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-09       Impact factor: 2.725

9.  Comparison of LV mass and volume measurements derived from electron beam tomography using cine imaging and angiographic imaging.

Authors:  Songshou Mao; Junichiro Takasu; Janis Child; Sivi Carson; Ronald Oudiz; Matthew J Budoff
Journal:  Int J Cardiovasc Imaging       Date:  2003-10       Impact factor: 2.357

Review 10.  Assessment of left ventricular function by three-dimensional echocardiography.

Authors:  Boudewijn J Krenning; Marco M Voormolen; Jos R T C Roelandt
Journal:  Cardiovasc Ultrasound       Date:  2003-09-08       Impact factor: 2.062

View more