Literature DB >> 11587453

Cardiac gated breath-hold black blood MRI of the coronary artery wall: an in vivo and ex vivo comparison.

S G Worthley1, G Helft, Z A Fayad, V Fuster, O J Rodriguez, A G Zaman, J J Badimon.   

Abstract

BACKGROUND: High resolution magnetic resonance (MR) imaging of the coronary artery wall in vivo has been limited by the cardiac and respiratory motion, flow artifacts as well as the relatively small size of the coronary arteries. We sought to validate in vivo black blood MR imaging of the coronary artery wall using a double inversion recovery fast spin echo MR imaging sequence with limited breath-holding and cardiac gating for suppression of motion artifacts by comparison with ex vivo MR imaging.
METHODS: Yorkshire albino swine (n = 6) were used in this study and coronary lesions were induced with balloon angioplasty. Four weeks after balloon injury of the coronary arteries MR imaging of the coronary artery lesions was performed. High resolution in vivo and ex vivo images of the coronary artery wall and lesions were obtained using a double inversion recovery fast spin echo sequence in a 1.5 T MR system. There was a statistically significant agreement (p < 0.0001) between measurements of vessel wall area (r = 0.87, slope = 0.87) and maximal wall thickness (r = 0.84, slope = 0.88) from in vivo and ex vivo MR images of the coronary arteries. The mean differences between in vivo and ex vivo measurements were 0.56 +/- 1.98 mm2 for vessel wall area and 0.02 +/- 0.36 mm for maximal wall thickness.
CONCLUSIONS: Using breathholding and cardiac gating, it is possible to perform high resolution MR imaging of the coronary artery wall in vivo with good suppression of motion artifacts with a double inversion recovery fast spin echo black blood imaging sequence.

Entities:  

Mesh:

Year:  2001        PMID: 11587453     DOI: 10.1023/a:1010688122184

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  14 in total

1.  New black blood pulse sequence for studies of the heart.

Authors:  S Campos; V Martinez Sanjuan; J J Garcia Nieto; V Belloch; A Lucas; M J Masip; P Nogues; J C Martinez; G Zannoli; H Lejay; J Celma
Journal:  Int J Card Imaging       Date:  1999-04

2.  Fast selective black blood MR imaging.

Authors:  R R Edelman; D Chien; D Kim
Journal:  Radiology       Date:  1991-12       Impact factor: 11.105

3.  High resolution ex vivo magnetic resonance imaging of in situ coronary and aortic atherosclerotic plaque in a porcine model.

Authors:  S G Worthley; G Helft; V Fuster; Z A Fayad; J T Fallon; J I Osende; M Roqué; M Shinnar; A G Zaman; O J Rodriguez; P Verhallen; J J Badimon
Journal:  Atherosclerosis       Date:  2000-06       Impact factor: 5.162

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  A preliminary report comparing magnetic resonance coronary angiography with conventional angiography.

Authors:  W J Manning; W Li; R R Edelman
Journal:  N Engl J Med       Date:  1993-03-25       Impact factor: 91.245

6.  Prolonged thrombin inhibition reduces restenosis after balloon angioplasty in porcine coronary arteries.

Authors:  R Gallo; A Padurean; V Toschi; J Bichler; J T Fallon; J H Chesebro; V Fuster; J J Badimon
Journal:  Circulation       Date:  1998-02-17       Impact factor: 29.690

7.  Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA.

Authors:  R M Botnar; M Stuber; P G Danias; K V Kissinger; W J Manning
Journal:  Circulation       Date:  1999-06-22       Impact factor: 29.690

8.  Serial magnetic resonance imaging of experimental atherosclerosis detects lesion fine structure, progression and complications in vivo.

Authors:  M P Skinner; C Yuan; L Mitsumori; C E Hayes; E W Raines; J A Nelson; R Ross
Journal:  Nat Med       Date:  1995-01       Impact factor: 53.440

9.  Noninvasive In vivo high-resolution magnetic resonance imaging of atherosclerotic lesions in genetically engineered mice.

Authors:  Z A Fayad; J T Fallon; M Shinnar; S Wehrli; H M Dansky; M Poon; J J Badimon; S A Charlton; E A Fisher; J L Breslow; V Fuster
Journal:  Circulation       Date:  1998-10-13       Impact factor: 29.690

10.  Magnetic resonance images lipid, fibrous, calcified, hemorrhagic, and thrombotic components of human atherosclerosis in vivo.

Authors:  J F Toussaint; G M LaMuraglia; J F Southern; V Fuster; H L Kantor
Journal:  Circulation       Date:  1996-09-01       Impact factor: 29.690

View more
  3 in total

1.  Non-invasive coronary imaging: computed tomography or magnetic resonance imaging?

Authors:  C R Peebles
Journal:  Heart       Date:  2003-06       Impact factor: 5.994

2.  Multi-contrast high spatial resolution black blood inner volume three-dimensional fast spin echo MR imaging in peripheral vein bypass grafts.

Authors:  Frank J Rybicki; Dimitrios Mitsouras; Christopher D Owens; Amanda Whitmore; Marie Gerhard-Herman; Nichole Wake; Tianxi Cai; Qian Zhou; Michael S Conte; Mark A Creager; Robert V Mulkern
Journal:  Int J Cardiovasc Imaging       Date:  2010-03-24       Impact factor: 2.357

Review 3.  Optimal imaging strategies to assess coronary blood flow and risk for patients with coronary artery disease.

Authors:  Michael Jerosch-Herold; Raymond Y Kwong
Journal:  Curr Opin Cardiol       Date:  2008-11       Impact factor: 2.161

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.