Literature DB >> 11585311

The Freiburg Stereoacuity Test: automatic measurement of stereo threshold.

M Bach1, C Schmitt, M Kromeier, G Kommerell.   

Abstract

BACKGROUND: There is a need for a stereotest with the following properties: (1) Natural viewing conditions, i.e. stimulus contours visible for each eye alone, but no or hardly any cue for monocular detection, and (2) suitability for threshold determination over a wide range of disparities. To comply with these requirements, we developed the Freiburg Stereoacuity Test.
METHOD: The stimulus configuration is shown on a visual display unit (VDU) using phase-difference haploscopy with ferromagnetic liquid crystal shutters. The stereo target consists of a vertical bar that can be presented "in front of' or "behind" a frame. The sizes of the bar and the frame are kept constant relative to the stereo disparity. Anti-aliasing allows for disparities finer than the pixel raster. To mask monocular cues the bar is displaced randomly to the right or left. The stereo threshold was determined in two observers with normal eyes, using first the method of constant stimuli and then the best PEST. Both procedures were repeated with observers wearing scatter transparencies that reduced their visual acuity to about 1/10. In addition, the two observers with insight into the test design and two strabismic patients performed the best PEST procedure with one eye only.
RESULTS: With constant stimuli both observers achieved a stereoacuity of 2.6 arcsec and 3.1 arcsec, respectively, taking a hit rate of 75% as the threshold. The best PEST revealed a stereoacuity of 2.5 arcsec and 3.0 arcsec, respectively. The scatter transparencies raised the threshold to 261 and 257, respectively. With one eye only, the two observers with insight into the test design exploited the subtle position cue and reached a coarse pseudostereopsis. The two strabismic patients did not utilise the position cue.
CONCLUSION: The Freiburg Stereoacuity Test allows determination of stereoacuity over a wide range of disparities (1-1000 arcsec). Although the stimuli can be seen with each eye alone, monocular depth cues are sufficiently masked. The Freiburg Stereoacuity Test is available at http://www.ukl.uni-freiburg.de/aug/bach/fst/.

Entities:  

Mesh:

Year:  2001        PMID: 11585311     DOI: 10.1007/s004170100317

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  6 in total

1.  [Investigation of color vision using a web-based color vision test].

Authors:  J Kuchenbecker; T Wecke; R Wiermer; F W Röhl; H Lindner; W Behrens-Baumann
Journal:  Ophthalmologe       Date:  2004-03       Impact factor: 1.059

Review 2.  Stereo vision and strabismus.

Authors:  J C A Read
Journal:  Eye (Lond)       Date:  2014-12-05       Impact factor: 3.775

3.  [Validity of a web-based color vision test for screening examinations of color vision].

Authors:  J Kuchenbecker; F W Röhl; A Wesselburg; J Bernarding; W Behrens-Baumann
Journal:  Ophthalmologe       Date:  2007-01       Impact factor: 1.059

4.  Calibration tools for PC-based vision assessment.

Authors:  David J Rolkosky; Gislin Dagnelie; Kevin Kramer; Gary Havey; Gregory J Seifert
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

5.  ASTEROID: A New Clinical Stereotest on an Autostereo 3D Tablet.

Authors:  Kathleen Vancleef; Ignacio Serrano-Pedraza; Craig Sharp; Gareth Slack; Carla Black; Therese Casanova; Jess Hugill; Sheima Rafiq; James Burridge; Vito Puyat; Josee Ewane Enongue; Henry Gale; Hannah Akotei; Zoe Collier; Helen Haggerty; Kathryn Smart; Christine Powell; Kate Taylor; Michael P Clarke; Graham Morgan; Jenny C A Read
Journal:  Transl Vis Sci Technol       Date:  2019-02-28       Impact factor: 3.283

6.  Screening for Stereopsis Using an Eye-Tracking Glasses-Free Display in Adults: A Pilot Study.

Authors:  Fang Liu; Jing Zhao; Tian Han; Yang Shen; Meng Li; Jingrong Liu; Dong Yang; Yong Fang; Li Yan; Xingtao Zhou
Journal:  Front Med (Lausanne)       Date:  2022-01-17
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.