Literature DB >> 15004715

[Investigation of color vision using a web-based color vision test].

J Kuchenbecker1, T Wecke, R Wiermer, F W Röhl, H Lindner, W Behrens-Baumann.   

Abstract

BACKGROUND: Screening tests of visual functions using the Internet are theoretically possible. To use these tests as a screening test, they must deliver comparable results with conventional test procedures. A web-based color vision test was developed based on pseudoisochromatic color plates.
METHOD: The web-based color vision test was developed according to the pseudoisochromatic color plates by Velhagen and Broschmann using the programming-languages HTML, Java, and Perl. Sixty-five voluntary subjects, including nine color-deficient subjects, were examined by luminescence color plates (via web-based color vision test) and pigment color plates (via book). The statistical analysis was performed by determining the correspondence and the 95%-confidence interval.
RESULTS: The correspondence of the test results for all subjects was 0.98 and the 95%-confidence interval was within 0.91 and 0.99. The correspondence of the test results in the group of color-deficient subjects was 1.0 and because of the limited number the 95%-confidence interval was within 0.71 and 1.0.
CONCLUSIONS: The web-based color vision test with luminescence color plates for color-efficient and color-deficient subjects delivers test results comparable to pigment color plates under standardized examination conditions. Further studies are needed to examine if the web-based color vision test can also be used as an Internet screening test.

Mesh:

Year:  2004        PMID: 15004715     DOI: 10.1007/s00347-003-0915-y

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  13 in total

1.  [Options and limits of visual function tests available on the internet].

Authors:  J Kuchenbecker; H Lindner; W Behrens-Baumann
Journal:  Ophthalmologe       Date:  2002-11       Impact factor: 1.059

2.  [Evaluating visual function with visual display graphics on the Macintosh II computer].

Authors:  C Huber
Journal:  Klin Monbl Augenheilkd       Date:  1992-05       Impact factor: 0.700

Review 3.  Raster-scan cathode-ray tubes for vision research--limits of resolution in space, time and intensity, and some solutions.

Authors:  M Bach; T Meigen; H Strasburger
Journal:  Spat Vis       Date:  1997

4.  Color vision testing with a computer graphics system: preliminary results.

Authors:  G Arden; K Gündüz; S Perry
Journal:  Doc Ophthalmol       Date:  1988-06       Impact factor: 2.379

5.  Computer automated visual acuity testing for visual screening.

Authors:  D Wong; A Plumb
Journal:  Trans Ophthalmol Soc U K       Date:  1986

6.  [The Freiburg Vision Test. Automated determination of visual acuity].

Authors:  M Bach
Journal:  Ophthalmologe       Date:  1995-04       Impact factor: 1.059

7.  [The Freiburg Vision Test. A computer-assisted procedure with sequential strategy].

Authors:  K Mittelviefhaus; M Bach; A Jedynak; G Kommerell
Journal:  Ophthalmologe       Date:  1993-04       Impact factor: 1.059

8.  Selective loss of chromatic sensitivity in demyelinating disease.

Authors:  L Fallowfield; J Krauskopf
Journal:  Invest Ophthalmol Vis Sci       Date:  1984-06       Impact factor: 4.799

9.  [Vision test program for ophthalmologists on Apple II, IIe and IIc computers].

Authors:  C Huber
Journal:  Klin Monbl Augenheilkd       Date:  1985-03       Impact factor: 0.700

10.  Red-green mixture thresholds in congenital and acquired color defects.

Authors:  K L Sellers; G M Chioran; S J Dain; S C Benes; M Lubow; K Rammohan; P E King-Smith
Journal:  Vision Res       Date:  1986       Impact factor: 1.886

View more
  4 in total

1.  [Classification of biomedical research reports as a reference for evidence-based medicine in ophthalmology. A survey considering as example the journal Der Ophthalmologe].

Authors:  H P N Scholl; M Fleckenstein; T U Krohne; F G Holz
Journal:  Ophthalmologe       Date:  2005-12       Impact factor: 1.059

2.  [Web-based analysis of Stilling's color plates].

Authors:  J Kuchenbecker
Journal:  Ophthalmologe       Date:  2014-12       Impact factor: 1.059

3.  [Validity of a web-based color vision test for screening examinations of color vision].

Authors:  J Kuchenbecker; F W Röhl; A Wesselburg; J Bernarding; W Behrens-Baumann
Journal:  Ophthalmologe       Date:  2007-01       Impact factor: 1.059

4.  [Investigation of color vision in acute unilateral optic neuritis using a web-based color vision test].

Authors:  J Kuchenbecker; M Blum; F Paul
Journal:  Ophthalmologe       Date:  2016-03       Impact factor: 1.059

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.